Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2S36CE-4PAE2M66 3-Phase Switched Rack PDU
The Server Technology C2S36CE-4PAE2M66 is a 400V, 3-phase switched power distribution unit built for data center and network operations center racks that need per-outlet control and metering without dedicating a full rack unit's worth of depth to power hardware. Rated for 32A input on a 230/400V Wye IEC 60309 3P+N+PE plug, it delivers 22kW of usable capacity across 36 total outlets — 24x C13 and 12x C19 — making it a fit for high-density server, storage, and network video recording racks where a single rack PDU needs to carry mixed IEC power loads. At 70 inches tall and only 2.2 inches wide by 2.5 inches deep, the C2S36CE-4PAE2M66 mounts vertically in a 0U zero-U configuration, running the full height of the rack without consuming horizontal rack space that would otherwise hold servers, switches, or recording appliances.
Overview
This is a switched PDU, meaning each outlet (or outlet group, depending on branch configuration) can be monitored and controlled remotely rather than being a passive power strip. The branch circuit design uses 16A breakers per circuit with a 10 kAIC interrupt rating for North America, which matters when you're protecting downstream equipment from fault currents in a shared electrical closet or colo cage. Ethernet connectivity at 10/100/1000 Mbps lets the C2S36CE-4PAE2M66 report into existing network monitoring tools over a standard copper uplink instead of requiring a proprietary management channel.
Key Features
- 22kW input capacity at 32A/400V 3-phase: supports dense server and storage racks pulling significant continuous load without derating concerns common on single-phase PDUs — relevant when consolidating multiple lower-capacity strips into one managed unit.
- 36 total outlets (24x C13, 12x C19): the C13/C19 mix covers both standard 1U-2U server power cords and higher-draw equipment like blade chassis or storage arrays that terminate in C20 plugs, avoiding the need for adapter cables that add failure points.
- C13 outlets rated 10A @ 230V L-N, C19 outlets rated 16A @ 230V L-N: per-outlet current limits let you plan load distribution across the unit precisely instead of guessing at a shared strip rating.
- Branch circuit breakers at 16A with 10 kAIC interrupt rating: isolates a fault to a single branch instead of tripping the whole PDU, so one failed power supply doesn't take down every outlet on the rack.
- GUI metering accuracy of ±1% on voltage, current, active power, apparent power, and energy: billing-grade measurement precision for colo environments charging by actual draw, or for capacity planning where a few percent of error compounds across dozens of racks.
- ±3% power factor and ±10% crest factor accuracy: gives enough visibility into load quality to flag problem circuits (non-linear loads, harmonics) before they cause nuisance trips elsewhere in the facility.
- 10/100/1000 Mbps Ethernet management: integrates into standard network monitoring and DCIM tooling over copper, so the C2S36CE-4PAE2M66 reports status alongside the rest of your network video recorders and switching infrastructure rather than living on an isolated management network.
- Quiescent unloaded power draw under 10W: the PDU's own overhead is negligible against a 22kW budget, so nearly all your provisioned capacity goes to actual IT load.
- Operating range of 0°C to 60°C, 8-90% RH: tolerates warm aisle containment and less-than-ideal HVAC conditions in secondary equipment rooms, not just tightly controlled primary data centers.
- Storage range of -30°C to 80°C: survives uncontrolled warehouse or shipping conditions before installation without derating on arrival.
- Compliance to EN IEC 62368-1, EN 55032, EN 55035, and RoHS: confirms the unit meets current audio/video and IT equipment safety and EMC standards for commercial deployment, plus RoHS materials compliance for environments with sustainability procurement requirements.
Integration & Compatibility
The C2S36CE-4PAE2M66's Ethernet-based management and standard metering protocols mean it slots into existing rack power monitoring workflows rather than requiring a separate management console. For sites planning out a full rack build, pairing this PDU with a network video recorder deployment or dense switching stack means checking total connected load against the 22kW/32A ceiling before commissioning — a step worth confirming during PoE and power planning for the rest of the rack. Because it occupies zero rack units when mounted vertically, it pairs naturally with high-density network switches and server chassis where every U of front-panel space is committed to compute or connectivity, not power infrastructure. The Server Technology C2S36CE-4PAE2M66 belongs in the broader power distribution units category alongside the rest of the Server Technology catalog for sites standardizing on one PDU platform across multiple racks.
Frequently Asked Questions
Q: What input voltage and plug does the C2S36CE-4PAE2M66 require?
A: It requires a 230/400V 3-phase Wye supply terminating in an IEC 60309 3P+N+PE 6Hr plug, rated for 32A input.
Q: How many outlets does the C2S36CE-4PAE2M66 have and what type?
A: It has 36 outlets total: 24x C13 (10A @ 230V L-N) and 12x C19 (16A @ 230V L-N).
Q: What is the total power capacity of the C2S36CE-4PAE2M66?
A: The unit is rated for 22kW of input power capacity at 32A on a 400V 3-phase circuit.
Q: Does the C2S36CE-4PAE2M66 support remote monitoring?
A: Yes. It includes an Ethernet port (10/100/1000 Mbps) and a GUI with ±1% metering accuracy on voltage, current, active power, apparent power, and energy.
Q: How much rack space does the C2S36CE-4PAE2M66 use?
A: It is a vertical 0U unit measuring 70 inches tall by 2.2 inches wide by 2.5 inches deep, so it does not consume horizontal rack unit space.
Q: What is the operating temperature range for the C2S36CE-4PAE2M66?
A: 0°C to 60°C with 8%RH to 90%RH humidity, and -30°C to 80°C for storage.

The first number I check on any 3-phase PDU spec sheet is the branch breaker rating, and on the C2S36CE-4PAE2M66 that's 16A per branch with a 10 kAIC interrupt rating — enough headroom to isolate a failed power supply on a single C13 or C19 run without tripping the whole 22kW unit. That's the difference between losing one server and losing a rack.
Technical Highlights:
- 36-outlet mixed C13/C19 layout: 24x C13 at 10A and 12x C19 at 16A covers standard 1U servers and higher-draw storage/blade equipment off one unit — no adapter cables needed on either end.
- ±1% metering accuracy on voltage, current, and power: this is billing-grade precision, not a rough estimate — matters if you're allocating power costs by rack or circuit in a shared facility.
- Quiescent draw under 10W against a 22kW budget: the PDU itself is essentially a rounding error on your power bill, so your capacity planning numbers reflect actual IT load, not PDU overhead.
Deployment Considerations:
- At 70 inches tall and 2.2 inches wide, this mounts as a 0U vertical PDU — plan cable management on the rack's rear rails accordingly, since it runs the full rack height and needs clearance for cord bend radius on both C13 and C19 whips.
- The 400V 3-phase Wye input with IEC 60309 3P+N+PE plug means you need that specific 3-phase circuit already run to the rack; this is not a drop-in replacement for a single-phase 120V/208V strip, so confirm your electrical infrastructure before ordering.
This is the right PDU for a data center or NOC operator standardizing high-density racks on 3-phase power who needs granular per-outlet metering for chargeback or capacity audits — the C2S36CE-4PAE2M66 (often searched as C2S36CE 4PAE2M66) makes sense specifically where 22kW-class racks are the norm, not the exception.
Compare with similar
Server Technology Smart Master PRO2 (36) - C2S36CE-4PAE2M66
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology