Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2S36TE-YQME2999 Configurable Alt-Phase HDOT PDU
Overview
The C2S36TE-YQME2999 is a Smart Master PRO2 (36) rack power distribution unit from Server Technology, built around configurable alternating-phase High Density Outlet Technology (HDOT) outlets. It's rated for 208V 3-phase Wye service at 60A, with 6 branch circuit breakers dividing the load across the outlet bank. This is a data center and server room infrastructure product, not a plug-and-play consumer strip — it's sized and phased for cabinets running dense, mixed-load server and networking gear.
Key Features
- 208V 3PH Wye input: matches standard data center 3-phase distribution, letting you balance load across phases at the rack rather than running everything off a single leg.
- 60A rated capacity: sized for high-density cabinets where blade servers, switches, and storage arrays are stacked tightly and single-phase strips run out of headroom.
- 6 branch circuit breakers (6BR): segments the outlet bank into protected zones, so a fault or overload on one branch trips locally instead of dropping the whole rack.
- Configurable alt-phase HDOT outlets: alternating-phase outlet layout supports load balancing decisions at install time based on the actual equipment being racked, rather than a fixed factory phase assignment.
- 36-outlet Smart Master PRO2 platform: gives enough outlet count to consolidate multiple lower-capacity strips into one managed unit per cabinet.
- TAA Compliance: relevant when this PDU is being procured against contracts that require Trade Agreements Act-compliant sourcing.
Integration & Compatibility
As a 3PH Wye 60A unit, the C2S36TE-YQME2999 needs to be matched to existing rack PDU whip and receptacle infrastructure already provisioned for that voltage and amperage — confirm upstream panel capacity and receptacle type before ordering. Pair it with compatible rack-mounted recording infrastructure or server hardware in the same cabinet, and review your power planning guide when sizing branch circuits across a multi-rack deployment. If this configuration doesn't match your phase or amperage requirement, Server Technology's Smart Master PRO2 line is built around configurable options — check a variant with different amperage or breaker count in the same family before settling on a spec.
Frequently Asked Questions
Q: What voltage and phase does the C2S36TE-YQME2999 run on?
A: It's rated 208V, 3-phase Wye configuration.
Q: How many branch circuit breakers does the C2S36TE-YQME2999 have?
A: Six branch circuit breakers (6BR), segmenting the outlet bank for localized fault protection.
Q: What's the maximum amperage rating on the C2S36TE-YQME2999?
A: 60A.
Q: Is the C2S36TE-YQME2999 TAA compliant?
A: Yes, this unit is listed as TAA Compliance.
Q: Does the C2S36TE-YQME2999 (sometimes searched as C2S36TE YQME2999) use fixed or configurable phase outlets?
A: It uses configurable alternating-phase HDOT outlets, allowing phase assignment to be set based on the deployment's load-balancing needs.

The C2S36TE-YQME2999 crossed my bench as a spec question, not an install — a customer needed to confirm it would actually match their panel before committing budget. On paper it's a 208V 3-phase Wye unit rated to 60A with 6 branch breakers, which is the detail that actually matters here: get the phase and amperage wrong on a PDU order and you've got hardware that can't be terminated to your existing whip.
Technical Highlights:
- 208V 3PH Wye: matches standard 3-phase data center distribution rather than single-phase, so load balancing happens across three legs instead of one.
- 60A rating with 6BR: six branch breakers split that 60A capacity into protected zones instead of one big fused bank.
- Configurable alt-phase HDOT outlets: phase assignment on the outlet bank isn't fixed at the factory, so it can be set to match the actual load profile in the cabinet.
Deployment Considerations:
- Confirm your upstream panel and whip are already provisioned for 208V 3PH Wye at 60A before ordering — this isn't a unit you adapt to single-phase 120V service.
- The published specification here doesn't include outlet count or connector types, so verify those details against the exact configuration before finalizing a cabinet layout.
This is the right spec sheet to hand your electrical contractor when you're standardizing a row of high-density racks on 3-phase Wye service and need branch-level breaker protection rather than one shared circuit per cabinet.
Compare with similar
Server Technology Smart Master PRO2 (36) - C2S36TE-YQME2999
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology