Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2S36TE-YCMFAM99 36-Outlet Switched Metered PDU
Overview
The Server Technology C2S36TE-YCMFAM99 is a vertical, zero-U switched and metered rack PDU built for data center and server room racks where per-outlet control and accurate power data matter more than a bare strip of outlets. It's a 0U vertical mount unit — 70 inches tall, 2.2 inches wide, 2.5 inches deep — meaning it fits in the rear rack channel without eating usable rack unit space for servers or network gear. Rated at 208V input with an 8.6kW capacity, the C2S36TE-YCMFAM99 targets racks running mixed C13/C-type IT loads plus a few 120V accessory devices on the same strip.
Key Features
- 18x C13 outlets rated ≤12A @ 208V L-L: covers standard IEC C14 server and network switch power cords without adapters — enough outlet count for a fully populated rack of 1U/2U servers.
- 18x Cx outlets rated ≤16A @ 208V L-L: higher-current outlets for blade chassis, storage arrays, or PDU-fed UPS loads that draw more than a standard C13 circuit can handle.
- 3x NEMA 5-20R outlets (≤16A @ 120V L-N): lets you power a KVM, console switch, or other 120V accessory from the same unit instead of running a separate outlet strip into the rack.
- NEMA L21-30P input plug, 30A input / 24A rated: matches standard twist-lock whip circuits common in colocation and enterprise data halls — confirm your facility's receptacle before ordering to avoid a field-swap.
- Per-outlet branch circuit breakers at 20A, 10 kAIC interrupt rating: an overloaded or shorted device trips its own breaker instead of taking down the whole strip — isolates the fault to one outlet, not the rack.
- Measurement accuracy ±1% on voltage, current, and power: metering data is tight enough to trust for capacity planning and billing-grade reporting, not just a rough gauge.
- 10/100/1000 Mbps Ethernet plus RS-232 serial: the PDU integrates into out-of-band management networks over copper Ethernet at full gigabit speed, with serial as a local console fallback for initial setup or when the network port is unavailable.
- RJ-12 link port and 2x 4P4C temperature/humidity sensor inputs: daisy-chain link ports reduce the number of network drops needed per rack row, and native environmental sensor inputs mean you can monitor rack-level temperature and humidity without a separate appliance.
- Quiescent power draw under 10W: the PDU's own overhead is negligible against an 8.6kW load — it won't meaningfully skew your capacity math.
- Operating range 0°C to 60°C, 8-90% RH, up to 2km elevation: covers standard data center environments as well as less climate-controlled telecom or edge closets.
- UL 489, CSA C22.2 No. 5, IEC/EN 60947-2, UL 62368-1, FCC Part 15 Class A compliance: the breaker and equipment safety certifications you'd check for in a facility that requires documented compliance before rack power goes live.
Integration & Compatibility
The gigabit Ethernet interface and RS-232 serial console put the C2S36TE-YCMFAM99 in line with standard out-of-band DCIM and remote power management tooling used across network power distribution units, so it slots into an existing lights-out management VLAN alongside other Server Technology PDU deployments. If you're planning a new rack build, pair outlet count and breaker sizing decisions here with a broader power and PoE planning guide before finalizing your one-line diagram. C2S36TE-YCMFAM99 (often searched as C2S36TE YCMFAM99) is the exact model to reference when matching replacement units or expansion PDUs across a row.
What's in the Box
Evidence for this listing does not include a verified package contents list, so that section is omitted here — outlet counts, breaker configuration, and mounting orientation are documented above from the manufacturer specification.
Frequently Asked Questions
Q: What input plug does the C2S36TE-YCMFAM99 use?
A: It terminates in a NEMA L21-30P twist-lock plug rated for 30A input (24A rated current) at 208V.
Q: How many outlets does the C2S36TE-YCMFAM99 have?
A: 39 total: 18x C13 outlets (≤12A @ 208V L-L), 18x Cx outlets (≤16A @ 208V L-L), and 3x NEMA 5-20R outlets (≤16A @ 120V L-N).
Q: What's the total power capacity of the C2S36TE-YCMFAM99?
A: 8.6kW at 208V input.
Q: Does the C2S36TE-YCMFAM99 provide per-outlet metering?
A: Yes — voltage, current, and power are measured with ±1% accuracy for capacity planning and reporting.
Q: What's the warranty on the C2S36TE-YCMFAM99?
A: 2-year limited manufacturer warranty.
Q: Can the C2S36TE-YCMFAM99 monitor rack temperature and humidity?
A: Yes, it has 2x 4P4C sensor inputs for external temperature/humidity probes.

What stands out on the C2S36TE-YCMFAM99 is the outlet mix: 18 C13, 18 higher-current Cx, and 3 NEMA 5-20R on a single 8.6kW strip. That's a deliberate design for racks that aren't uniform — most of your servers pull standard C13 cords, but you've got a couple of storage shelves or blade enclosures that need the 16A Cx circuits, plus maybe a KVM on 120V. One PDU, one whip, no mixing strips.
Technical Highlights:
- Per-outlet breakers at 20A / 10 kAIC: a shorted power supply trips its own branch breaker instead of tripping the 30A main and dropping the whole rack — that's the difference between one dead server and a full outage ticket.
- ±1% measurement accuracy across voltage, current, and power: tight enough that I'd trust this data for chargeback billing or capacity forecasting, not just a rough load check.
- Gigabit Ethernet plus RS-232 and RJ-12 link: full-speed remote management with a serial fallback for initial commissioning, and the link port lets you chain units down a row without burning a switch port per PDU.
Deployment Considerations:
- Confirm your facility whip terminates in a NEMA L21-30P receptacle before ordering — this unit ships with that plug type and isn't field-convertible to a different input.
- At 70 inches tall and 0U vertical mount, measure your rear rack channel clearance first, especially in racks with side-mounted cable managers or vertical PDU brackets already installed.
This is the right call for a mixed-load enterprise server rack — say, a row of 2U application servers on C13 combined with a couple of SAN shelves needing higher-current Cx outlets — where you need branch-level breaker isolation and metering accuracy good enough to feed into DCIM reporting, not just an on/off outlet strip.
Compare with similar
Server Technology Smart Master PRO2 (36) - C2S36TE-YCMFAM99
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology