Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: PR1000LCD
UPC: 649532602506
Condition: New
Write a Review 10% OFF

CyberPower PR1000LCD 1000VA Sine Wave UPS with LCD

CyberPower PR1000LCD 1000VA/1000W Smart App Sinewave UPS The CyberPower PR1000LCD delivers 1000VA/1000W of pure sine wave battery backup and power con…

$800.00 $721.99 SAVE $78
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

CyberPower PR1000LCD 1000VA Sine Wave UPS with LCD

$800.00
$721.99

Overview

SKU: PR1000LCD
UPC: 649532602506
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

CyberPower PR1000LCD 1000VA/1000W Smart App Sinewave UPS

The CyberPower PR1000LCD delivers 1000VA/1000W of pure sine wave battery backup and power conditioning in a mini-tower form factor engineered for corporate servers, network infrastructure, and telecom installations. Line interactive topology with automatic voltage regulation protects Active PFC power supplies common in modern rack-mount equipment, surveillance NVRs, PoE switches, and access control panels. The removable multifunction LCD panel provides real-time load monitoring, runtime estimates, and diagnostic alerts via a 4.5-foot cable, allowing front-panel visibility regardless of equipment rack position.

Key Features

  • Pure sine wave output on AC and battery power — compatible with Active PFC server and network gear that rejects simulated sine wave UPS units
  • 1000VA/1000W capacity supports fully-loaded 8-port PoE++ switches, 4-bay NVRs, or dual rack-mount servers simultaneously
  • 10.5 minutes runtime at 50% load gives graceful shutdown time when utility power fails during off-hours surveillance recording
  • Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages without switching to battery, extending battery service life in areas with unstable utility power
  • Eight NEMA 5-15R outlets (four critical load priority) with 1030 joules surge protection across all receptacles
  • USB, serial, and optional SNMP remote monitoring via RMCARD205 for integration with building management systems and NOC dashboards
  • PowerPanel Business Edition software enables scheduled shutdowns, load shedding, and automated email alerts when runtime thresholds are breached
  • User-replaceable 2×12V/12Ah sealed lead-acid batteries with quick-change access and 3-hour fast recharge
  • $375,000 Connected Equipment Guarantee backs surge protection claims with actual financial coverage
  • 4ms transfer time ensures zero service interruption for IP cameras, door controllers, and VoIP systems

The PR1000LCD addresses the most common failure point in security and network installations: dirty utility power that causes nuisance reboots, corrupted NVR recordings, and premature failure of sensitive electronics. Line interactive topology with buck-boost AVR automatically corrects input voltage deviations from 78-149VAC to a stable 120VAC ±5% output without engaging the battery, a critical distinction from standby UPS designs that wear batteries through constant switching. Pure sine wave output on both AC and battery modes matches utility-grade waveform quality, eliminating the high-frequency harmonics in simulated sine wave (stepped approximation) UPS units that cause Active PFC power supplies to fault or operate in reduced-efficiency modes. For integrators deploying Axis cameras, Hanwha NVRs, HPE switches, or any server-grade equipment with Active PFC, sine wave output is non-negotiable — simulated sine wave will trigger power supply shutdown or void equipment warranties.

Battery runtime scales predictably with load: 3.1 minutes at full 1000W load, 10.5 minutes at 500W, extended further at lighter loads typical of surveillance edge deployments. A four-camera PoE+ installation drawing 120W would achieve approximately 45 minutes of runtime, sufficient for most short-duration utility interruptions or orderly remote shutdown via network management during extended outages. The eight NEMA 5-15R outlets divide into two groups: four critical-load outlets that remain powered until battery depletion, and four that can be load-shed via software to extend runtime for essential devices when prolonged outages are detected. PowerPanel Business Edition enables scheduled shutdowns, email/SMS alerts, and automatic safe OS shutdown for connected servers when remaining runtime drops below configurable thresholds. USB and serial interfaces support legacy equipment; the optional RMCARD205 SNMP card provides SNMPv3 remote monitoring, syslog integration, and web-based configuration for NOC inclusion alongside facility infrastructure.

The removable LCD panel mounts separately from the UPS chassis via a 4.5-foot cable, solving the visibility problem inherent in floor-mounted or rear-rack-positioned UPS units where the display faces away from the operator. Real-time metrics include input/output voltage, load percentage, battery charge level, estimated runtime, and fault codes. The mini-tower form factor occupies 6.7"W × 8.7"H × 17"D and weighs 44 lbs — designed for floor placement beside server racks or desktop deployment in IDF closets where rack space is unavailable. Metal construction and convection cooling (no fans at <70% load) ensure quiet operation in office environments. Battery replacement requires no tools and completes in under two minutes without powering down connected equipment, a routine maintenance task that field technicians can perform during quarterly service visits without scheduling outages.

Input voltage tolerance spans 78-149VAC before transfer to battery, covering the voltage sag/swell conditions that cause IT equipment reboots during HVAC compressor startup, elevator motor engagement, or utility voltage fluctuations common in older commercial buildings. The 1030-joule surge suppression rating protects against transient overvoltages from nearby lightning strikes and utility switching events; all eight outlets receive both battery backup and surge protection, unlike entry-level UPS designs that reserve battery backup for a subset of outlets. Transfer time averages 4ms, well within the hold-up time of modern switch-mode power supplies (typically 16-20ms), ensuring zero interruption to IP cameras, VoIP phones, PoE lighting controllers, and access control panels during battery transitions. Output frequency regulation holds 50/60Hz ±0.1Hz regardless of input frequency variation, critical for installations near generators or in regions with loose grid frequency control.

UL1778 and cUL 107.3 certifications confirm compliance with North American safety standards for standalone UPS systems and IT equipment installation. Energy Star certification validates efficiency claims during normal AC operation. FCC DOC Class A approval permits commercial/industrial deployment (not residential). RoHS compliance ensures export eligibility and aligns with corporate sustainability mandates. The 3-year warranty covers the UPS chassis and internal components; batteries carry a prorated warranty reflecting their consumable nature. The $375,000 Connected Equipment Guarantee provides financial recourse if surge protection failure causes downstream equipment damage, a differentiator that demonstrates manufacturer confidence in protection circuitry — integrators should document connected equipment serial numbers and retain proof of proper grounding to support potential claims. For surveillance, access control, and network infrastructure requiring Active PFC compatibility, remote monitoring, and runtime sufficient for graceful shutdown, the PR1000LCD occupies the price/performance intersection where sine wave output and line interactive AVR become standard rather than premium features.

Specifications
Product Type: Uninterruptible Power Supply (UPS)
Series: Smart App Sinewave
Capacity VA: 1000 VA
Capacity Watts: 1000 W
Waveform: Pure Sine Wave (AC and Battery)
Topology: Line Interactive with AVR
Form Factor: Mini-Tower
Dimensions: 6.7 x 8.7 x 17 inches (W x H x D)
Weight: 44 lbs
Input Voltage: 120 VAC nominal (78-149 VAC operating range)
Output Voltage: 120 VAC ± 5%
Frequency Range: 47-63 Hz input, 50/60 Hz ± 0.1Hz output
Transfer Time: 4 ms typical
Outlets: 8 x NEMA 5-15R (all battery & surge protected, 4 critical load priority)
Input Plug: NEMA 5-15P with 6 ft cord
Surge Protection: 1030 Joules
Runtime Full Load: 3.1 minutes at 1000W
Runtime Half Load: 10.5 minutes at 500W
Battery Type: Sealed Lead-Acid, 2 x 12V/12Ah, user replaceable
Recharge Time: 3 hours quick charge, 8 hours eco mode
Connectivity: USB, Serial, SNMP (optional RMCARD205), EPO
LCD Display: Multifunction LCD with 4.5 ft removable cable
Management Software: PowerPanel Business Edition
Operating Temperature: 32-104°F (0-40°C)
Operating Humidity: 0-95% non-condensing
Material: Metal construction
Color: Black
Standards & Certifications: UL1778, cUL 107.3, FCC DOC Class A, Energy Star, RoHS
Warranty: 3 Year Limited Warranty, $375,000 Connected Equipment Guarantee
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources