Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FR9TP77Y001F079 12-Fiber Singlemode Plenum Interconnect Trunk Cable

Overview

The Panduit FR9TP77Y001F079 is a factory-terminated 12-fiber singlemode plenum-rated interconnect assembly designed for structured cabling deployments in commercial and enterprise environments where code compliance and optical performance are non-negotiable. At 79 feet, this trunk is sized for cross-connect runs between distribution frames, equipment rooms, and backbone pathways where a pre-terminated, plug-and-play assembly eliminates field termination variables entirely.

The plenum jacket rating means this cable can route through air-handling spaces — drop ceilings, raised floors, and HVAC plenums — without requiring conduit, which simplifies installation in multi-tenant office buildings, data centers, and surveillance head-end rooms where cable paths run through occupied airspace. Polarity B configuration is specified, so verify your patch panel and transceiver polarity scheme before ordering; mismatched polarity in a singlemode link is a common commissioning error that a factory-labeled assembly makes easy to catch and correct at the planning stage.

Singlemode glass supports long-distance transmission with lower attenuation than multimode, making this the right fiber type for backbone runs connecting remote IDF closets, outdoor IP camera aggregation points, or NVR head-ends separated by meaningful distances inside a campus or large facility. The 12-fiber count provides enough strands for a mix of uplink, camera backbone, and spare capacity in a single, managed assembly rather than running individual patch cables or field-terminated pigtails.

The Optimized Insertion Loss (IL) designation in the full product name indicates this assembly is built to a tighter-than-standard insertion loss specification — a meaningful factor in long singlemode links where link budget margins are calculated per connector pair. Note the California Proposition 65 warning: this cable contains lead compounds in the plastic jacket materials.

For structured cabling planning, fiber backbone selection, or multi-fiber trunk sizing guidance, explore the fiber optic cables and assemblies category or review structured cabling solutions for complementary trunk, patch panel, and enclosure options. Panduit's full Panduit catalog covers the complete channel from outlet to core. For pairing with active equipment, see compatible transceivers and DACs.

Key Features

  • 12-Fiber Singlemode Core: twelve individual singlemode fibers in a single managed assembly — enough capacity to support multiple backbone links, camera aggregation runs, and spares without the clutter of individual patch cables.
  • Plenum-Rated Jacket (CMP): routes through air-handling spaces without conduit, reducing installation labor and meeting fire code requirements in commercial buildings where open plenum pathways are the norm.
  • 79-Foot Factory Length: pre-measured and terminated at the factory, eliminating field splicing variables and cutting commissioning time on structured cabling projects.
  • Polarity B Configuration: factory-labeled polarity simplifies troubleshooting and ensures consistent polarity management across your patch panels — confirm your switch and transceiver polarity scheme matches before deployment.
  • Optimized Insertion Loss: tighter IL specification than standard assemblies helps preserve link budget on longer singlemode runs where every connector pair contributes to total optical loss.

Compatibility

This assembly is designed for use with standard LC or MPO/MTP singlemode interface equipment — verify the connector type from the full Panduit product documentation before ordering, as the connector style is not confirmed in available evidence. Compatible with singlemode transceivers (OS1/OS2) used in IP surveillance NVRs, managed switches, and fiber-to-the-edge aggregation equipment. Consult Panduit's structured cabling documentation to confirm compatibility with specific patch panels, enclosures, and adapter sleeves in your installation.

Frequently Asked Questions

Q: What does the Polarity B designation mean on the FR9TP77Y001F079?

A: Polarity B refers to the fiber strand mapping scheme used in the factory termination. In multi-fiber assemblies, polarity determines which fiber at one end connects to which fiber at the other end. Polarity B follows a specific TIA-568 standard method. You must verify that your patch panels, transceivers, and switches are configured for the same polarity scheme — a mismatch causes link failures that can be difficult to diagnose without knowing the polarity in advance.

Q: Is the FR9TP77Y001F079 suitable for outdoor use?

A: No. This cable carries a plenum (CMP) jacket rating, which is designed for indoor air-handling spaces. It is not rated for direct burial, outdoor UV exposure, or wet locations. For outdoor fiber runs between buildings or to exterior camera locations, a separate outdoor-rated fiber assembly is required.

Q: Can I use the FR9TP77Y001F079 with multimode transceivers?

A: No. This is a singlemode fiber assembly. Singlemode fiber has a much smaller core diameter (typically 9 microns) than multimode (50 or 62.5 microns) and requires singlemode-compatible transceivers and light sources. Using singlemode fiber with multimode transceivers will result in severe signal loss or no link at all.

Q: What connector type does the FR9TP77Y001F079 use?

A: The specific connector type (e.g., LC, SC, MPO/MTP) is not confirmed in the available product evidence. Consult Panduit's full product documentation or contact a fiber specialist to confirm connector style before ordering, especially if you need to match existing panel port types.

Q: Does this cable comply with California Proposition 65?

A: The FR9TP77Y001F079 carries a California Proposition 65 warning. The plastic materials used in the cable jacket contain lead and lead compounds, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. Review the Prop 65 warning details at P65Warnings.ca.gov before deployment in California facilities.

Marty Allison
Marty Allison

The FR9TP77Y001F079 is a 79-foot, 12-fiber singlemode plenum interconnect trunk — the kind of assembly that saves real time on structured cabling projects where the alternative is field-terminating individual fibers in a ceiling plenum with no clean work surface and a commissioning deadline. The factory Optimized Insertion Loss spec is the detail I look at first on singlemode assemblies: every connector pair in a long backbone link eats into your link budget, and a tighter-than-standard IL rating gives you more headroom before you start troubleshooting marginal signal levels at the switch or NVR.

Technical Highlights:

  • 12-Fiber Count: enough strands in one managed assembly to support multiple simultaneous backbone links — camera aggregation, NVR uplink, and spares — without running separate cables for each circuit.
  • Plenum (CMP) Jacket: routes through open air-handling plenums without conduit in commercial occupancies, which is frequently the only practical cable path in retrofit installations above drop ceilings.
  • Polarity B, Factory-Labeled: polarity mismatches are one of the most common and least obvious commissioning failures on multi-fiber trunks — having it labeled and fixed at the factory is worth more than it sounds during a multi-run installation day.

Deployment Considerations:

  • Confirm your patch panel adapter sleeves and transceiver interface types match the connector style on this assembly before it ships — the connector type is not confirmed in current evidence and a wrong-connector trunk on a critical backbone run is a project delay.
  • Polarity B must be matched end-to-end across all passive elements in the link; if your existing infrastructure was built to Polarity A or C, you will need a crossover adapter or a different assembly — not a field re-termination.

This trunk is a practical fit for enterprise surveillance head-end rooms and IDF-to-MDF backbone runs in multi-floor commercial buildings, where a pre-terminated plenum assembly eliminates field work in occupied airspace and the 12-fiber count handles a full camera aggregation tier plus uplink capacity in a single, traceable cable.

Specifications
Fiber Count: 12
Fiber Type: Singlemode
Length: 79 FT
Country of Origin: China, Costa Rica
UNSPSC: 26121607
Q&A
Reviews

Panduit FR9TP77Y001F079 Singlemode 12-Fiber Trunk Cable – 79 ft

$442.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources