Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric NSYSFRSEDC206100 42U Edge Micro DC Floor-Standing Rack Enclosure

Overview

The APC by Schneider Electric NSYSFRSEDC206100 is a 42U floor-standing enclosed cabinet designed for edge micro data center deployments where physical security, structural integrity, and disciplined cable management matter as much as rack density. At 600mm wide and 1000mm deep (23.6" × 39.4"), it fits within standard raised-floor tiles while providing a genuine 33.54-inch usable rail depth — enough headroom for full-depth servers, dense UPS hardware, or a mixed security/compute stack without compromise. This is a purpose-built enclosure from APC by Schneider Electric's infrastructure line, sourced factory-new through channel-direct distribution.

Key Features

  • 42U Rack Height: Forty-two rack units in a single floor-standing cabinet means you can consolidate an entire edge node — NVRs, PoE switches, UPS, and compute — without splitting across multiple enclosures. Fewer cabinets mean fewer cable runs between them and a smaller physical footprint overall.
  • 881.85 lb Static Weight Capacity: A stationary load rating of nearly 900 pounds gives you real headroom for dense deployments. Full-depth servers, multi-bay NVRs, and stacked UPS hardware all push weight fast — this rating means the enclosure won't be the constraint in a high-density build.
  • 249.12 lb Dynamic/Rolling Weight Capacity: The rolling capacity determines how much equipment can be safely installed while the cabinet is moved. At 249 lb, you can roll a moderately populated rack into position without unloading first — useful during staged commissioning of edge sites with limited personnel.
  • 33.54" Usable Rail Depth: Depth is often the overlooked spec when sizing enclosures. At 33.54 inches of usable rail depth, full-depth 1U servers, large UPS units, and deep NVR chassis all mount without forcing the door to remain open or requiring horizontal cable managers to double as spacers.
  • Vented Design with Fan Cooling: Active fan cooling combined with vented panels means heat doesn't build up passively between equipment cycles. For edge micro DC nodes running 24/7 surveillance storage or compute loads, this is the right thermal approach — passive-only enclosures in enclosed cabinets frequently create hot-spot conditions that reduce drive and component lifespan.
  • Floor-Standing Enclosed Cabinet Form Factor: The enclosed cabinet design limits physical access to authorized personnel, which matters in edge deployments at branch offices, warehouses, or remote sites without a dedicated server room. Access control at the cabinet level is your last physical layer before the equipment itself.
  • 78.7" Overall Height: At 78.7 inches tall, the cabinet requires standard commercial ceiling clearance (8 ft minimum recommended) and fits through standard 80-inch commercial door frames during installation — confirm your access path before delivery on constrained sites.

Integration & Compatibility

The rack enclosure follows EIA-310 standard 19-inch rack mounting, making it compatible with virtually all commercial networking, storage, UPS, and NVR equipment. The 600mm × 1000mm external footprint aligns with standard raised-floor tile dimensions used in micro data center designs. Pair this enclosure with appropriate UPS and power distribution units from the same product family for a complete edge infrastructure stack. Cable entry points and venting locations should be confirmed against your specific PDU and cable management accessories before rack population to avoid airflow short-circuits.

For deployments integrating surveillance systems, the 42U capacity is sufficient to house multiple high-channel-count NVRs alongside dedicated PoE switch tiers and edge storage nodes in a single, physically secured enclosure — a configuration particularly common in retail distribution centers and campus security operations.

Frequently Asked Questions

Q: What is the rack unit capacity of the NSYSFRSEDC206100?

A: The NSYSFRSEDC206100 provides 42U of rack space, sufficient for a full edge micro data center stack including NVRs, switches, UPS hardware, and compute nodes.

Q: What is the maximum weight this enclosure can support?

A: The static stationary weight capacity is 881.85 lb. The dynamic rolling weight capacity (equipment installed while moving) is 249.12 lb. Size your rack population accordingly — exceed the rolling limit only with the cabinet stationary and leveled.

Q: What are the external dimensions of the NSYSFRSEDC206100?

A: External dimensions are 23.6" wide × 39.4" deep × 78.7" tall. Usable rail depth is 33.54 inches. Verify door clearance (minimum ~80" height recommended) and floor load capacity at your installation site.

Q: Does this enclosure include active cooling?

A: Yes. The NSYSFRSEDC206100 features fan-based active cooling combined with vented panels to manage heat in continuously loaded edge deployments. This is appropriate for 24/7 surveillance storage and compute workloads where passive cooling alone is insufficient.

Q: What is the warranty on this product?

A: The NSYSFRSEDC206100 carries a 1-year manufacturer warranty.

Q: Is this enclosure compatible with standard 19-inch rack equipment?

A: Yes. The enclosure uses EIA-310 standard 19-inch mounting rails, compatible with virtually all commercial servers, NVRs, switches, UPS units, and patch panels.

Marty Allison
Marty Allison

The NSYSFRSEDC206100 hits a specific sweet spot: 42U of enclosed, actively cooled rack space in a 600×1000mm footprint with an 881-lb static load rating. I spec this enclosure when the deployment is an edge micro DC at a warehouse or branch site — the kind of location where you need full-depth equipment capacity, physical access control, and reliable thermal management, but you're not building a full server room.

Technical Highlights:

  • 881.85 lb Static Capacity: Real-world dense racks — dual NVRs, a multi-bay storage shelf, a rack-mount UPS, and a full PoE switch tier — easily reach 400–600 lb populated. The 881-lb rating gives you room to grow without re-speccing the cabinet mid-project.
  • 33.54" Rail Depth: Full-depth 1U servers and large rack-mount UPS chassis typically run 28–32 inches. The 33.54-inch usable depth clears them cleanly without door modification or cable management hacks that restrict airflow.
  • Fan-Assisted Active Cooling: Enclosed cabinets trap heat aggressively. The built-in fan cooling paired with vented panels prevents the thermal buildup that shortens drive life in surveillance storage nodes — critical when NVRs are running 24/7 with high write loads.

Deployment Considerations:

  • At 78.7 inches tall and 361.56 lb empty, this cabinet requires at minimum a two-person installation team and a verified floor load rating at the destination. Edge sites in older buildings frequently have floor load limits below 250 lb/ft² — confirm before delivery.
  • The 249.12-lb rolling weight limit is the one spec that catches integrators off guard: if you pre-populate the rack at the staging area and then try to roll it into a tight server closet, you need to stay under that threshold or risk frame stress. Plan to partially populate on-site if your loaded weight will exceed it.

For a retail distribution center or campus security operations node running a 32+ channel NVR stack alongside PoE switch infrastructure, the NSYSFRSEDC206100 delivers the physical capacity and thermal discipline that an open-frame rack simply can't provide in an unattended edge location.

Specifications
Rack Height: 42U
Rack Depth: 33.54"
Width: 23.6"
Height: 78.7"
Depth: 39.4"
Weight: 361.56 lb
Dynamic Rolling Weight Capacity: 249.12 lb
Static Stationary Weight Capacity: 881.85 lb
Rack Type: Enclosed Cabinet
Features: Vented
Cooling: Fan
Form Factor: Floor Standing
Warranty: 1 Year
Manufacturer Part Number: NSYSFRSEDC206100
freight: 788.67
Q&A
Reviews

APC by Schneider Electric SF 20X6X10 Edge DC Solution - NSYSFRSEDC206100

$2,252.88
$2,251.99

RELATED PRODUCTS

Save $686.01
APC by Schneider Electric Schneider Electric APC - SRT192BP
Add to Cart The item has been added

APC by Schneider Electric SRT192BP

APC by Schneider Electric Schneider Electric APC - SRT192BP

192V lead acid rackmount battery pack designed to extend the runtime of compatible Smart-UPS SRT series uninterruptible power supplies

    In stock · Ships same business day Free shipping over $499
    $2,560.00 $1,873.99 Save $686.01
    The item has been added Add to quote
    $2,560.00 $1,873.99 Save $686.01
    Save $686.01 Add to cart Add to quote
    Save $141.01
    APC by Schneider Electric Schneider Electric AP9551 - Power
    Add to Cart The item has been added

    APC by Schneider Electric AP9551

    APC by Schneider Electric Schneider Electric AP9551 - Power

    14-outlet, 120V rack mount PDU from APC by Schneider Electric, designed to distribute power from a single NEMA L5-20P source across up to 14 devices

      Usually Ships in 2-3 Weeks Free shipping over $499
      $426.00 $284.99 Save $141.01
      The item has been added Add to quote
      $426.00 $284.99 Save $141.01
      Save $141.01 Add to cart Add to quote

      System Design, Deployment & Technical Support

      Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

      Fixed scope • Fixed price

      System Design Assistance

      • Get help validating product compatibility
      • Coverage requirements
      • Storage planning and deployment architecture before you buy.
      Request Design Help

      Deployment & Configuration Support

      • Access fixed-scope support for rollout planning
      • User setup guidance
      • Migration and system standardization across single-site or multi-site deployments
      View Support Services

      Guides, Tools & Calculators

      • PoE requirements
      • Storage retention
      • Camera selection and deployment methodology
      Open Technical Resources