Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit RAFC10IW-X Surface Raceway Right Angle Fitting

The Panduit RAFC10IW-X right angle fitting routes LD10 and LDPH10 Pan-Way surface raceway around 90-degree corners without kinking cables or violating bend-radius limits. One-piece hinged PVC construction with adhesive backing snaps onto existing raceway runs—no fasteners, no cutting—so you can install clean corner transitions in seconds. Off-white finish matches standard Panduit LD10 profiles. Sold in 10-packs for mid-size retrofit jobs where exposed conduit isn't an option and in-wall fishing would blow the budget.

Key Features

  • One-piece hinged design for snap-on installation—no screws or adhesive removal
  • Controlled bend radius prevents cable stress and maintains TIA/EIA compliance
  • Adhesive backing option for semi-permanent wall mounting at transition points
  • 3.18" × 3.18" footprint (80.8 mm) fits LD10 and LDPH10 raceway profiles
  • Rigid PVC construction rated UL94V-0 and FT4 for plenum-equivalent fire safety
  • Off-white finish coordinates with existing Pan-Way installations

The RAFC10IW-X measures 3.18 inches square with a 0.93-inch profile height (23.6 mm), sized to mate with Panduit's LD10 and LDPH10 surface raceway channels without adapters. The one-piece hinged lid lifts to accept cable bundles, then snaps shut over the raceway joint—no need to pre-thread cables through the fitting. Internal bend geometry maintains a controlled radius that keeps Cat 6A, fiber, and power cables within manufacturer bend-radius specs, critical when you're running PoE++ to cameras or pulling 12-strand OM4 to a floor switch.

Rigid PVC construction carries UL94V-0 and FT4 ratings, meaning it self-extinguishes and produces minimal smoke—important for installations in occupied spaces or near air-handling plenums where local AHJs enforce NFPA 90A interpretations. The adhesive backing secures the fitting to drywall, painted CMU, or cubicle panels without visible fasteners; for higher-stress corners (doorways, high-traffic walls), you can drill through the base and use #6 screws at the preformed pilot points. Off-white PVC won't yellow under fluorescent or LED lighting, so retrofits blend into existing Panduit raceway systems without a patchwork appearance.

Integrators spec the RAFC10IW-X when running low-voltage cabling along baseboards, chair rails, or ceiling perimeters in commercial spaces—offices, retail back-of-house, healthcare clinics, schools—where fishing wire through walls isn't feasible due to concrete/CMU construction, asbestos abatement costs, or tenant lease restrictions. Surface raceway keeps cables accessible for adds/moves/changes while meeting NEC Article 800 (communications circuits) and TIA-568 cable-support requirements.

The 10-piece pack supports a typical conference-room retrofit (four corners plus spare fittings) or a small-office camera/access-control installation where you're dropping five to eight runs from a central rack. Pair with Panduit LD10 base and cover, inside/outside elbows, and surface-mount boxes to build a complete pathway system. Carton quantity of 50 fits larger rollouts—multitenant office buildings, K-12 classroom wings—where you're standardizing on Pan-Way across 20+ rooms and need volume pricing without custom orders.

The RAFC10IW-X solves the corner-routing problem every integrator faces on surface-mount jobs: you can't just bend LD10 raceway 90 degrees without crushing cables or cracking the PVC, and cutting/mitering fittings on-site wastes billable time. This factory-molded right-angle fitting gives you a TIA/EIA-compliant corner in under a minute—snap the fitting onto the raceway joint, lift the hinged cover, lay in your cables, close the lid. UL94V-0 and FT4 ratings mean you can document fire-safety compliance for AHJ inspections without waiting for engineer letters or field testing. For LD10/LDPH10 retrofit projects where clean aesthetics and fast installation drive scope decisions, the RAFC10IW-X is the fitting that keeps cable pathways both code-compliant and installer-friendly.

Specifications
Product Type: Surface Raceway Right Angle Fitting
Brand: Panduit
MPN: RAFC10IW-X
Sub-Brand: Pan-Way
Compatible Raceway: LD10, LDPH10
Material: Rigid PVC
Color: Off White
Overall Dimensions: 3.18" W × 3.18" L × 0.93" H
Metric Dimensions: 80.8 mm W × 80.8 mm L × 23.6 mm H
Installation Type: Snap-on with adhesive backing
Design: One-piece hinged
Fire Rating: UL94V-0, FT4
Standards Compliance: TIA/EIA Standards
Package Quantity: 10
Carton Quantity: 50
UPC: 07498352572
Application: Low-voltage data, fiber optic, and electrical wiring routing
Type: Surface Raceway Fitting
Mount Type: Wall; Corner
Sub Brand: Pan-Way®
Height In: 0.93
Height Mm: 23.6
Width In: 3.18
Width Mm: 80.8
Carton Qty: 50
Package Qty: 10
Standards: UL94V-0, FT4, Meets TIA/EIA Standards
Cable Category: wire-routing-management-protection
Type: Surface Raceway Right Angle Fitting
Q&A
Reviews
Have Questions?

Panduit RAFC10IW-X Right Angle Surface Raceway Fitting

$3.90
$2.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources