Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VA5N21A1 is a 20A, 120V single-phase horizontal rack power distribution unit that combines switched outlet control with a built-in rack transfer switch — a pairing that eliminates the need for a separate ATS in space-constrained 0U deployments. Designed for data center rows, edge compute cabinets, and high-density lab racks, the VA5N21A1 delivers individual outlet switching, real-time current/voltage/power monitoring, and an enterprise-grade protocol stack from a compact horizontal form factor. If your environment demands per-outlet power cycling without sending a technician to the rack, or you need automatic source failover baked directly into the PDU, this is the unit to evaluate.
The VA5N21A1 integrates with Vertiv power management and monitoring tools and is compatible with third-party DCIM platforms that support SNMP v1/v2c/v3 or Modbus TCP. The dual AAA protocol support (LDAP, RADIUS, TACACS+) allows the unit to slot into enterprise identity management environments without requiring a standalone local user database. For teams managing a mixed fleet of rack PDUs across a DCIM platform, the unit's SNMP MIB can be imported for consistent polling. The SMTP alerting and Syslog output integrate directly with most NOC toolchains. Review your power distribution planning requirements — particularly whether you need a 20A/120V single-phase circuit or require a 208V or 30A variant — before ordering. The NEMA L5-20P input plug requires a matching 20A/120V locking receptacle at the source; confirm your cabinet's whip or floor PDU output before deploying.
Q: What is the difference between the monitored and switched functions on the VA5N21A1?
A: The monitored function provides real-time current, voltage, and power readings at the outlet level, giving you visibility into load distribution. The switched function allows remote power cycling or on/off control of individual NEMA 5-20R outlets — useful for rebooting hung devices without a site visit. The VA5N21A1 includes both capabilities plus a rack transfer switch function for dual-source redundancy.
Q: What input plug does the VA5N21A1 use, and what circuit does it require?
A: The VA5N21A1 uses a NEMA L5-20P locking plug and requires a 20A, 120V (100–120V nominal) single-phase circuit. The unit accepts 50 or 60 Hz input frequency. Confirm your cabinet or floor PDU has a matching NEMA L5-20R receptacle before ordering.
Q: Which network management protocols does the VA5N21A1 support?
A: The VA5N21A1 supports SNMP v1, v2c, and v3; HTTPS and SSH for encrypted management access; DHCP, NTP, SMTP, Syslog, LDAP, RADIUS, TACACS+, Modbus TCP, RSTP, and both IPv4 and IPv6. This covers integration with most enterprise NMS, DCIM, and AAA platforms without additional hardware.
Q: Can the VA5N21A1 be managed out-of-band if the Ethernet port is unreachable?
A: Yes. The unit includes a USB port and a serial (RS-232) port for out-of-band console access — useful for initial configuration or recovery when the network management interface is misconfigured or the management VLAN is unavailable.
Q: What is the total power capacity of the VA5N21A1?
A: The VA5N21A1 is rated at 20A input with a maximum load of 1.9 kW at 120V. It distributes this across six NEMA 5-20R outlets. Per standard de-rating practice, plan for a maximum continuous load of approximately 16A (80% of the 20A breaker rating) to avoid nuisance tripping.
Q: Does the VA5N21A1 mount horizontally or vertically?
A: The VA5N21A1 is designed for horizontal mounting in standard EIA/IEC 19-inch rack cabinets. It occupies zero U-space in the device mounting area (0U form factor), installing in the rack's horizontal cable management or mounting channel rather than taking up rack units.

The VA5N21A1 sits at an interesting intersection in the rack PDU market: it's the unit you reach for when a basic monitored PDU isn't enough (you need switching) but you also need to solve for power redundancy in the same rack footprint without bolting on a separate ATS. The NEMA L5-20P / 6-outlet NEMA 5-20R configuration at 1.9 kW puts it squarely in the edge compute, branch office server closet, and mid-density co-lo cage bracket — not a hyperscale row.
Technical Highlights:
Deployment Considerations:
This unit is the right call for a branch office or co-location cage deployment where you need remote outlet reboot capability, dual-source failover, and DCIM-compatible telemetry — all without consuming a single rack unit of device space.