Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VA6N21A1 is a horizontal 0U rack-mount transfer switch PDU delivering 20A at 120V (1.9kW) with monitored outlet-level visibility across six NEMA 5-20R receptacles. Designed for single-phase deployments where both redundant power path management and granular per-outlet monitoring matter, the VA6N21A1 fits cleanly into dense 1U rack environments without consuming valuable rack units thanks to its horizontal 0U form factor. The NEMA L5-20P twist-lock input plug and 3-meter cable provide practical reach to a dedicated 20A circuit — the right combination for IT closets, network racks, and edge compute cabinets where source redundancy is non-negotiable.
Vertiv's Vertiv power distribution and infrastructure products cover the full range of data center and edge power needs. The VA6N21A1 sits within the monitored rack PDU segment — a step above basic metered PDUs because it adds transfer switching, meaning a failover path exists at the outlet group level rather than just at the panel.
The VA6N21A1 integrates with DCIM and monitoring platforms via SNMP-based network management using v1, v2c, or v3 — the v3 variant adds authentication and encryption, satisfying security requirements that block v1/v2c in hardened environments. RADIUS and TACACS+ integration means user authentication ties to your existing AAA infrastructure rather than local accounts. NTP synchronization keeps event timestamps accurate across Syslog and SMTP alert records. For facilities teams running BMS or DCIM platforms with Modbus TCP support, the VA6N21A1 can feed outlet-level power data directly into broader energy management dashboards — a meaningful advantage over PDUs limited to SNMP-only reporting. Pair with a compatible UPS system on the input feed to complete the redundant power architecture; the transfer switch function is most effective when both source paths are independently protected.
Q: What input plug does the VA6N21A1 use, and what circuit does it require?
A: The VA6N21A1 uses a NEMA L5-20P twist-lock plug and requires a dedicated 20A, 120V single-phase circuit. The 3-meter input cord provides flexibility for routing to the panel.
Q: Does the VA6N21A1 support SNMP v3 for encrypted management?
A: Yes. The unit supports SNMP v1, v2c, and v3. SNMP v3 adds authentication and encryption, making it suitable for environments with stricter network security policies that prohibit unencrypted SNMP v1/v2c traffic.
Q: Can the VA6N21A1 integrate with RADIUS or TACACS+ for user authentication?
A: Yes. Both RADIUS and TACACS+ are listed in the supported network protocol stack, allowing administrator authentication to route through your existing AAA infrastructure instead of relying solely on local accounts.
Q: How many outlets does the VA6N21A1 provide, and what type are they?
A: The VA6N21A1 provides six NEMA 5-20R outlets. These accept standard North American 5-20 plugs used on most 1U rackmount servers, switches, and storage devices.
Q: Does the VA6N21A1 support Modbus TCP for BMS or DCIM integration?
A: Yes. Modbus TCP is included in the supported protocol list, enabling integration with Building Management Systems and DCIM platforms that use industrial Modbus-based data collection alongside or instead of SNMP.
Q: What is the 0U horizontal form factor, and how does it mount in a rack?
A: 0U means the unit mounts horizontally in the rack without consuming a numbered rack unit slot — typically along the side channel or in a dedicated PDU mounting position. This preserves all front-facing 1U slots for active equipment.

The VA6N21A1 is a well-specified monitored transfer switch PDU for integrators who need outlet-level power visibility and source redundancy in a single horizontal 0U unit. The protocol stack here — SNMP v3, RADIUS, TACACS+, Modbus TCP, Syslog, SMTP — is broader than what you typically see at the 20A/6-outlet tier, and it matters when you're deploying into environments with formal change management or security auditing requirements.
Technical Highlights:
Deployment Considerations:
This PDU fits cleanly in a network edge cabinet or IT closet where you need monitored redundancy, AAA-integrated management, and Modbus TCP for a facilities dashboard — without stepping up to a full smart PDU with per-outlet switching that adds cost you don't need if manual outlet control isn't a requirement.