Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VP6N11A1
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Monitored Outlet Level EC 15A 120V 1.4KW Horizontal (12) NEMA 5-15R - VP6N11A1

Vertiv VP6N11A1 Monitored Outlet-Level Horizontal Rack PDUOverviewThe Vertiv VP6N11A1 is a horizontal, outlet-level monitored PDU designed for 1U rack…

$1,894.00 $1,298.99 SAVE $595
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Monitored Outlet Level EC 15A 120V 1.4KW Horizontal (12) NEMA 5-15R - VP6N11A1

$1,894.00
$1,298.99

Overview

SKU: VP6N11A1
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP6N11A1 Monitored Outlet-Level Horizontal Rack PDU

Overview

The Vertiv VP6N11A1 is a horizontal, outlet-level monitored PDU designed for 1U rack environments where IT and facilities teams need granular visibility into power consumption at the individual circuit level. Rated at 15A/120V (1.4kW), it delivers 12 NEMA 5-15R outlets on a NEMA 5-15P input cord — a straightforward fit for 1U horizontal rack positions running standard North American infrastructure. The LCD display gives at-a-glance readings without requiring a network connection, while the onboard Ethernet port opens full remote monitoring via a protocol stack that covers everything from SNMP v3 to TACACS+ to Modbus TCP.

Where basic rack PDUs simply distribute power, the VP6N11A1 measures it — tracking current, voltage, and real power per outlet. That means you can identify an overloaded circuit before it trips, spot inefficient or idle equipment drawing phantom loads, and report actual kWh consumption back to a DCIM or BMS without manual walkthroughs.

Key Features

  • Outlet-Level Monitoring (Current, Voltage, Power): Each of the 12 NEMA 5-15R outlets reports current draw, voltage, and real power independently. In a mixed-density rack — say, a combination of 1U servers and edge switches — you can isolate which device is pulling an anomalous load without a clamp meter and a ladder. That granularity matters when you're trying to enforce per-tenant power budgets or troubleshoot a nuisance-trip.
  • 15A/120V, 1.4kW Input: The NEMA 5-15P plug connects directly to a standard 15A branch circuit — no transformer, no special receptacle. At 1.4kW maximum, budget headroom carefully: fill all 12 outlets with 1.5A loads and you're already at the 80% NEC recommended limit. This is a correct-sized unit for a single lightweight edge rack, not a high-density compute row.
  • 12 NEMA 5-15R Outlets, Horizontal Mount: The horizontal form factor sits in a single 1U rack slot across the back of the cabinet, leaving vertical space free for equipment. Twelve NEMA 5-15R receptacles handle standard desktop-class plugs common on IP cameras, access control panels, NVRs, and edge networking gear — the typical load mix in a physical security or edge IT rack.
  • LCD Display: The integrated LCD presents live readings locally without requiring a laptop or network access. Useful during initial commissioning, field troubleshooting, or in environments where remote access credentials aren't immediately available.
  • Gigabit Ethernet (RJ-45) + Serial + USB Ports: The single RJ-45 port connects the PDU's management controller to the network. The serial port supports out-of-band console access — handy when the network path is down and you need to reconfigure the unit. The USB port supports local management or firmware updates depending on firmware revision.
  • Protocol Depth — SNMP v1/v2c/v3, HTTPS, SSH, RADIUS, TACACS+, LDAP, Modbus TCP, Syslog: This is not a consumer-grade monitoring PDU. SNMP v3 with RADIUS and TACACS+ authentication means the VP6N11A1 can slot into enterprise AAA infrastructure rather than relying on local credentials only. Modbus TCP integration lets DCIM and BMS platforms poll it natively alongside UPS and cooling systems. Syslog support feeds alerts into your SIEM without custom middleware.
  • IPv4 and IPv6 Dual-Stack with DHCP, NTP, SMTP: IPv6 support future-proofs the unit for networks already transitioned or in migration. DHCP simplifies initial IP assignment. NTP synchronizes timestamps for accurate event logs — critical when correlating PDU alerts with upstream switch or server logs. SMTP delivers email alerts when thresholds are crossed.
  • 3-Meter Input Cord: The 3m (approximately 10 ft) cord provides enough reach to route cleanly from a rear-of-rack horizontal mount to a floor-level or raised-floor receptacle without an extension cord, which would void the electrical rating.

Integration and Compatibility

The VP6N11A1 integrates with DCIM platforms, BMS systems, and network management suites through standard protocols. SNMP MIBs are available from Vertiv for import into SolarWinds, PRTG, Nagios, Zabbix, or similar NMS platforms — enabling threshold-based alerting and historical trending without proprietary software. Modbus TCP extends compatibility to building automation controllers that may not speak SNMP. The HTTPS/SSH management interface supports secure browser-based access and CLI scripting for environments that automate device configuration at scale. LDAP and RADIUS/TACACS+ integration means user authentication can be centrally managed rather than maintained per-device — a real operational difference when you're managing dozens of PDUs across multiple sites.

For physical security integrators deploying in a rack power context alongside network video recorders, edge switches, and access control panels, the outlet-level monitoring makes it straightforward to document power draw per device for commissioning reports and ongoing SLA compliance. Pair this with a compatible Vertiv UPS upstream for a complete power protection and monitoring chain. Consult a PoE switch selection guide if your adjacent equipment requires powered Ethernet — the VP6N11A1 itself provides no PoE output.

Frequently Asked Questions

Q: What is the maximum load the VP6N11A1 can handle?

A: The VP6N11A1 is rated at 15A, 120V, 1.4kW on a single NEMA 5-15P input. Per NEC guidelines, sustained load should not exceed 80% of rated capacity (12A / 1.12kW). Plan outlet assignments accordingly — this unit is sized for lightweight edge or physical security racks, not high-density compute.

Q: Does the VP6N11A1 support SNMP v3?

A: Yes. The VP6N11A1 supports SNMP v1, v2c, and v3, along with RADIUS, TACACS+, and LDAP for authentication. This allows integration into enterprise NMS platforms and centralized AAA infrastructure.

Q: Can the VP6N11A1 send email alerts when a power threshold is crossed?

A: Yes. The unit supports SMTP for email notifications and Syslog for integration with log management and SIEM platforms, enabling automated alerting on current, voltage, or power anomalies.

Q: How does the VP6N11A1 mount in a rack?

A: It is a horizontal, 0U-designated PDU designed to mount across the rear of a standard rack. It does not consume numbered rack units in the standard equipment bay — verify your specific cabinet's horizontal mounting channel dimensions before ordering.

Q: What network protocols does the VP6N11A1 support?

A: Supported protocols include DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, and Modbus TCP — covering most enterprise network management and building automation integration scenarios.

Q: Does the VP6N11A1 support IPv6?

A: Yes, the VP6N11A1 supports both IPv4 and IPv6 dual-stack operation, making it compatible with networks in IPv6 transition or fully migrated IPv6 environments.

Karl Wilson
Karl Wilson

The VP6N11A1 is the unit I reach for when a physical security integrator needs more than basic power distribution but isn't running a high-density compute environment that justifies a 20A or 30A three-phase PDU. The 15A/120V rating and 12 NEMA 5-15R outlets match the actual load profile of a typical edge security rack — a handful of NVRs, a PoE switch or two on bypass, an access control panel, and a couple of spare outlets for expansion. What differentiates the VP6N11A1 from a passive strip is the outlet-level monitoring: current, voltage, and real power per outlet reported back over SNMP v3 or Modbus TCP.

Technical Highlights:

  • Outlet-Level Monitoring: Per-outlet current, voltage, and real power readings — not just aggregate inlet data. You can see which specific device is drawing abnormally without clamp-meter walkthroughs, and set threshold alerts via SNMP traps or SMTP notifications before a nuisance-trip takes down the rack.
  • Enterprise AAA Integration (RADIUS, TACACS+, LDAP): Most monitored PDUs at this price tier use local credentials only. RADIUS and TACACS+ support means this unit authenticates through your existing network access infrastructure — no per-device password management across a distributed site portfolio.
  • Modbus TCP + SNMP v3 Dual Protocol: Modbus TCP lets building management and DCIM systems poll the PDU natively alongside UPS and HVAC equipment on the same BMS bus. SNMP v3 covers the IT side. Running both simultaneously is uncommon at this class level and avoids having to bridge protocols with middleware.

Deployment Considerations:

  • The 15A/1.4kW ceiling hits the NEC 80% continuous load rule at 12A aggregate. Map your outlet loads before ordering — if the rack carries any device drawing more than 1A continuously, you'll run out of headroom faster than the outlet count suggests. This is a single-circuit unit; there is no redundant input path.
  • The horizontal mount designation is listed as 0U, but physical fit depends on your specific cabinet's rear horizontal channel. Measure the channel width and PDU body dimensions before specifying — not every rack with horizontal mounting rails uses the same form factor standard.

The VP6N11A1 is a solid fit for enterprise physical security deployments where the customer requires per-outlet power reporting for tenant billing, commissioning documentation, or energy audit compliance — and where the load stays within a 15A/120V single-circuit envelope. It is not the right pick for a high-density server row or any rack running 208V or three-phase equipment.

Specifications
PDU types: Monitored
Type: Single-phase
Rack capacity: 0U
Mounting: Horizontal
Product colour: Black
Display: LCD
AC outlets quantity: 12 AC outlet(s)
Power plug: NEMA 5-15P
AC outlet types: NEMA 5-15R
Serial ports quantity: 1
Ethernet LAN (RJ-45) ports: 1
USB ports quantity: 1
Cable length: 3 m
Monitoring: Current, Power, Voltage
Supported network protocols: DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Nominal input voltage: 100-120 V
AC input frequency: 50/60 Hz
Maximum current: 15 A
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources