Vertiv Rpdu Rack Transfer Switch Monitored Unit Level 15A 120V 1.4KW Horizontal ( - VA4N11A0

Vertiv VA4N11A0 Monitored Rack Transfer Switch, 15A 120V 1.4kW, 10-Outlet Horizontal 1UOverviewThe Vertiv VA4N11A0 is a 1U horizontal rack-mount trans…

$2,180.00 $1,494.99 SAVE $685
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Rack Transfer Switch Monitored Unit Level 15A 120V 1.4KW Horizontal ( - VA4N11A0

$2,180.00
$1,494.99

Overview

SKU: VA4N11A0
UPC: 767041044676
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VA4N11A0 Monitored Rack Transfer Switch, 15A 120V 1.4kW, 10-Outlet Horizontal 1U

Overview

The Vertiv VA4N11A0 is a 1U horizontal rack-mount transfer switch designed for environments where uptime on a single power feed isn't acceptable. Running at 15A/120V with a 1.4kW capacity ceiling, it accepts dual input sources and distributes power across ten NEMA 5-15R receptacles — giving you a clean failover path without manual intervention when a primary feed drops. If you're building out a rack power distribution strategy that has to survive a PDU or circuit failure, this is the unit to evaluate. Vertiv's broader Vertiv power management line covers everything from basic PDUs to full UPS integration; the VA4N11A0 sits at the monitored transfer-switch tier, meaning you get real-time visibility and remote management, not just passive switching.

The unit-level monitoring capability means you're tracking conditions at the device level rather than relying solely on a branch circuit meter upstream — a meaningful distinction in dense rack environments where a single overloaded circuit can take down multiple loads.

Key Features

  • 1.4kW / 15A Capacity at 120V: Sized for standard 15A branch circuits, which covers the majority of 1U and 2U server, networking, and storage appliances. If you're running higher-draw devices (dual-PSU 2U servers at full load), size up to a 20A variant — this one is optimized for lighter compute density or edge/remote deployments.
  • 10 x NEMA 5-15R Outlets: Enough receptacles to feed a fully populated 1U switch shelf or a mixed row of appliances. All ten outputs sit behind the transfer logic, so a primary-source failure triggers a switchover across every connected device simultaneously — no partial coverage.
  • Dual-Source Transfer Switching: The core function — when Input A fails or degrades outside the 100–120V input range, the unit transfers to Input B. This eliminates single-point-of-failure exposure on critical rack loads without requiring a full UPS refresh.
  • 100–120V Input / 50–60Hz: Compatible with North American standard branch circuits. The 50Hz rating also covers international deployments running on North American-spec equipment — relevant for multi-site integrators standardizing hardware globally.
  • Enterprise Protocol Stack — SNMP v1/v2c/v3, RADIUS, TACACS+, LDAP: This is where the VA4N11A0 separates from basic transfer switches. SNMP v3 means encrypted, authenticated traps into your NMS or DCIM platform. RADIUS and TACACS+ authentication means access to the management interface is tied to your existing identity infrastructure — not a local password list that goes stale. LDAP integration extends the same principle to directory-based auth.
  • HTTPS, SSH, SMTP, Syslog: Encrypted web and CLI access are non-negotiable in any audited environment. SMTP alerting fires an email on transfer events; Syslog feeds your SIEM directly. Combine these and you have a full audit trail on every power event without manual log pulls.
  • IPv4/IPv6 Dual-Stack + DHCP/NTP: IPv6 support future-proofs the unit on networks already transitioning away from IPv4-only addressing. NTP sync keeps event timestamps accurate across distributed sites — critical when correlating power events to application logs post-incident.
  • RSTP Network Protocol: Rapid Spanning Tree support on the management network interface prevents bridging loops if the unit's management port is connected to a redundant switch fabric.
  • Operating Temperature to 60°C (140°F): Rated for hot-aisle conditions in high-density rows. A 60°C ceiling covers most raised-floor data center environments and edge locations without forced cooling — relevant if this unit lives in a telecom enclosure or industrial edge cabinet where ambient temps climb.
  • Compliance — UL Listed 62368, FCC Part 15 Class A, RoHS: UL 62368 (Audio/Video, IT, and Communications equipment safety) is the current standard replacing UL 60950 — applicable for enterprise IT deployments. FCC Class A restricts radiated emissions for commercial environments. RoHS compliance matters for EU-region deployments or organizations with environmental procurement mandates.

Integration and Compatibility

The VA4N11A0 integrates into network management and DCIM platforms via SNMP v1/v2c/v3, making it compatible with the majority of enterprise NMS tools including SolarWinds, PRTG, and Nagios-based systems. The RADIUS and TACACS+ support means it fits cleanly into Cisco ISE, FreeRADIUS, or similar AAA infrastructure without requiring a sidecar authentication proxy. For organizations running Vertiv's Trellis or Environet DCIM platform, native integration is the expected path. The horizontal 1U form factor (17 × 18 × 1.72 in, 17 lbs) drops into any standard EIA 19-inch rack without adapter hardware — zero clearance concerns in a full-depth 4-post cabinet. Consider pairing this unit with a UPS on each input feed if true dual-path redundancy (rather than just transfer switching) is the goal; the VA4N11A0 handles the switching layer but does not provide battery backup.

Frequently Asked Questions

Q: What is the maximum load the VA4N11A0 can support?

A: The VA4N11A0 is rated at 15A / 1.4kW at 120V. For safe continuous operation, plan to load it no higher than 80% of rated capacity — approximately 12A or 1.1kW — per standard NEC guidelines for continuous loads.

Q: What outlet type does the VA4N11A0 use?

A: It provides ten NEMA 5-15R receptacles on the output side, compatible with standard three-prong North American plugs. Input connections vary — confirm the input plug type with the product listing before ordering if your PDU whip or circuit uses a locking connector.

Q: Does the VA4N11A0 support encrypted management access?

A: Yes. The unit supports HTTPS for web-based management and SSH for CLI access, both of which are encrypted. SNMP v3 provides authenticated and encrypted trap/polling. RADIUS and TACACS+ are supported for AAA integration with enterprise identity infrastructure.

Q: What rack space does the VA4N11A0 occupy?

A: The unit is a 1U horizontal form factor measuring 17 inches wide, 18 inches deep, and 1.72 inches tall. It fits a standard EIA 19-inch rack without adapter hardware and weighs 17 lbs.

Q: Is the VA4N11A0 compatible with IPv6 networks?

A: Yes. The management interface supports both IPv4 and IPv6 dual-stack addressing, along with DHCP and NTP for automated IP assignment and time synchronization.

Q: What safety certifications does the VA4N11A0 carry?

A: The unit is UL Listed under standard 62368 (the current IT/AV equipment safety standard), FCC Part 15 Class A compliant for commercial environments, and RoHS compliant.

Ted Perry
Ted Perry

The VA4N11A0's protocol stack is what distinguishes it from generic transfer switches at this price point — specifically the combination of SNMP v3, RADIUS, TACACS+, and Syslog in a 1U horizontal unit running at 15A/120V. In audited data center environments, that's not a nice-to-have; it's often a compliance requirement that eliminates cheaper alternatives from the shortlist.

Technical Highlights:

  • SNMP v3 with RADIUS/TACACS+: Encrypted SNMP traps plus AAA integration means this unit fits directly into enterprise NMS and identity infrastructure — no local credential sprawl, no unencrypted management traffic on the wire.
  • 1.4kW / 10-outlet capacity: Ten NEMA 5-15R outputs at 1.4kW total headroom covers a fully loaded 1U network appliance shelf or a mixed row of edge compute devices. At 80% continuous load that's 1.1kW — plan your per-outlet load distribution before deployment.
  • 60°C operating ceiling: Rated for hot-aisle ambient conditions that would stress units with tighter thermal envelopes. In edge cabinets or telco enclosures without active cooling, the 140°F rating provides meaningful margin.

Deployment Considerations:

  • The 100–120V input range is North America-specific. Confirm both input feed voltages are within spec before commissioning — the unit does not support 208V or 240V inputs, which is a hard stop for high-density rows running on 208V branch circuits.
  • At 17 lbs and 18 inches deep, verify your rack's depth clearance and shelf weight rating before sliding this in. Standard 4-post cabinets at 28–30 inches deep are fine; shallower wall-mount enclosures may require a depth adapter or aren't viable at all.

This unit is the right call for edge data center deployments, co-location cages, and secondary machine rooms where you need dual-feed transfer switching with enterprise-grade management visibility but don't have budget or rack space for a full UPS-based redundancy stack on every circuit. The TACACS+ and Syslog support in particular make it a fit for financial services and healthcare environments with strict change-audit requirements.

Specifications
Operating Temp: 60C / 140F
Weight: 17 lbs
Height: 1.72 in
Width: 17 in
Depth: 18 in
Capacity: 1.4Kw (120V)
Input Voltage Range: 100-120V
Output Voltage Range: 120V
Output Options: (10) NEMA 5-15R
Location: Rack
Frequency: 50/60Hz
Protocols: DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
Listings: RoHS Compliant, FCC Part 15 Class A Compliance, UL Listed 62368
Operating Temperature: 60C / 140F
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources