Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv I10491 is a zero-U, vertically mounted, three-phase metered rack PDU rated at 50A/208V — purpose-built for high-density data center racks and equipment rooms where you need real-time power visibility without consuming valuable rack unit space. With 30 outlets split across C13 and C19 receptacles, it handles mixed server, storage, and networking loads from a single input circuit. The "upgradeable" designation means this unit ships as metered and can be field-upgraded to switched or outlet-level-monitored functionality, protecting your hardware investment as monitoring requirements evolve.
The rack power distribution category covers a wide range of PDU tiers; the I10491 sits at the metered tier — giving you branch-level current, voltage, and real power data without the per-outlet relay cost of a switched unit. If your operations team needs load data for capacity planning or needs to prove circuit headroom to a facilities auditor, this is the spec to look at.
The I10491 integrates into any standard rack PDU deployment supporting IEC C14/C20 input feeds at 200–240V three-phase. Its upgradeable architecture is a meaningful differentiator: as your monitoring maturity increases — from metered to switched to outlet-level energy monitoring — this unit can grow with your infrastructure rather than requiring a forklift replacement. Verify compatibility with your specific Vertiv upgrade module options and confirm input whip/connector type matches your facility's panel configuration before ordering. The black finish and vertical form factor are consistent with rack infrastructure standards across major cabinet vendors.
For facilities running environmental monitoring alongside power distribution, consider pairing this PDU with a compatible environmental monitoring unit that feeds into the same management interface. If you're deploying at scale across multiple racks, the per-unit metering data from the LED display can be aggregated via Vertiv's network management ecosystem when the appropriate upgrade card is installed.
Q: What outlet types and how many does the I10491 provide?
A: The I10491 provides 30 total AC outlets — a combination of IEC C13 (lower-current, standard for most 1U/2U servers) and IEC C19 (higher-current, for storage arrays and high-draw networking gear). Exact per-type counts should be confirmed against the product datasheet or Vertiv's product configuration tool.
Q: Is the I10491 a switched PDU or metered only?
A: It ships as a metered PDU — you get real-time current, voltage, and power monitoring at the unit level. The "upgradeable" designation means it supports field-installed upgrade modules to add switching or outlet-level monitoring capabilities without replacing the unit.
Q: What certifications does the I10491 carry?
A: The I10491 is UL & c-UL Listed to 62368-1 (the current IT/AV equipment safety standard), FCC Part 15 Class A compliant for commercial environments, and RoHS compliant for environmental procurement requirements.
Q: What is the input voltage and phase configuration?
A: The I10491 accepts 200–240V at 50/60 Hz on a three-phase input, rated at 50A maximum current. The nominal output voltage is 208V.
Q: Does the I10491 occupy rack unit space?
A: No. It is a 0U form factor designed for vertical mounting inside the side rail of a standard rack cabinet, preserving all rack unit positions for equipment.
Q: What monitoring data is available at the PDU?
A: The integrated LED display shows real-time current, voltage, and power (wattage/VA) at the unit level. Remote monitoring requires an optional network management card upgrade.

The I10491 lands squarely in the "I need real numbers, not just a breaker" tier of power distribution. The three-phase 50A/208V input with unit-level current, voltage, and power monitoring via the integrated LED display gives facilities and ops teams the data they need for capacity planning and load balancing — without paying for per-outlet switching they may never use. If your racks are running mixed C13/C19 loads and you want field upgrade headroom, this unit is worth the spec-in over a static metered PDU.
Technical Highlights:
Deployment Considerations:
This unit is well-positioned for phased enterprise data center deployments and colocation cage buildouts where UL 62368-1 listing is a hard acceptance requirement, rack density is high enough to justify three-phase input, and the operations team wants a clear upgrade path to switched or outlet-monitored PDU capability without a hardware forklift.