Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: J08B0B
UPC: 786776012187
Condition: New
Write a Review 48% OFF

Middle Atlantic Rckmnt Outs 0F/8B SWT 6FT - J08B0B

Middle Atlantic J08B0B Rack-Mount 8-Outlet Switched Power StripOverviewThe Middle Atlantic J08B0B is a rack-mount AC power strip designed for structur…

$183.93 $95.99 SAVE $88
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic Rckmnt Outs 0F/8B SWT 6FT - J08B0B

$183.93
$95.99

Overview

SKU: J08B0B
UPC: 786776012187
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic J08B0B Rack-Mount 8-Outlet Switched Power Strip

Overview

The Middle Atlantic J08B0B is a rack-mount AC power strip designed for structured wiring closets, equipment racks, and server enclosures where you need clean, switched power distribution without consuming front-of-rack space. The J08B0B puts all eight outlets on the rear of the unit — a deliberate layout choice that keeps cable management predictable in a dense rack and eliminates the temptation to route power cords across the front panel. Paired with a 6 ft (1.8 m) cord, it reaches a standard wall circuit or PDU input without forcing a custom extension.

Middle Atlantic is a well-established name in the Middle Atlantic rack power and enclosure lineup, and the J08B-series strips are a staple of AV and security integrators who need straightforward, reliable rack power for multi-device deployments. If you're building out a rack power distribution strategy across multiple enclosures, this unit fits the standard 1U footprint that most integrators plan around.

Key Features

  • 8 Rear-Mounted Outlets (0 Front): All eight outlets are positioned at the back of the strip. This matters in a working rack — rear outlets mean power cords route directly to equipment without crossing the front rails, keeping the front panel accessible for status checks and physical access. If your gear has right-angle plugs or you're running tight to the rear of the enclosure, plan cable depth accordingly.
  • Switched Design: A master switch lets you cut power to all connected equipment in one action. In a security or AV rack, this simplifies controlled restarts — useful during commissioning, troubleshooting, or scheduled maintenance windows when you need a clean power cycle across multiple devices simultaneously rather than pulling plugs one by one.
  • 120V / 15A Rating: Matched to a standard North American 15A branch circuit. Before loading the strip, add up the nameplate draw of every connected device — staying under 80% of the 15A rating (12A continuous) is standard practice and required by NEC for continuous loads. If your rack's aggregate draw approaches or exceeds that threshold, consider load balancing across two circuits or stepping up to a higher-amperage PDU.
  • 6 ft (1.8 m) Power Cord: The 6 ft cord covers the typical distance from a rack-mounted strip to a wall outlet or floor-level PDU without requiring an extension cord, which would introduce an additional connection point and a potential code compliance question. If your circuit is more than 6 ft away, plan the circuit routing before mounting the rack rather than relying on extensions.
  • 1U Rack-Mount Form Factor: Occupies a single rack unit, which is the standard allocation for power strips in most rack designs. Integrators planning a network rack or equipment enclosure can budget 1U per power strip in their rack unit count — straightforward to spec.
  • TAA Non-Compliant: The J08B0B is not TAA compliant. For federal government projects, GSA schedule bids, or any contract requiring TAA compliance, this unit is not eligible. Verify your project's compliance requirements before specifying — if TAA is a hard requirement, a different PDU from the Middle Atlantic or Legrand AV portfolio may apply.

Integration & Compatibility

The J08B0B is designed to fit standard 19-inch EIA equipment racks and Middle Atlantic rack enclosures. The rear-outlet layout is particularly practical in Middle Atlantic's own rack line, where the enclosure depth allows rear power strips to sit clear of equipment. The 120V / 15A rating is compatible with standard NEMA 5-15P receptacles on North American branch circuits.

For deployments involving PoE switches, NVRs, or access control panels in a rack, this strip handles the non-PoE AC side of the power architecture — the devices that don't draw from a PoE budget but still need clean, switched AC. It doesn't replace a UPS or provide surge suppression based on available evidence; if power conditioning or battery backup is a project requirement, pair it with an appropriate UPS in the same rack.

For rack power planning in multi-device security deployments, account for inrush current from cameras, NVRs, and access panels during a switched power-on event — particularly relevant here since all eight outlets switch simultaneously.

Frequently Asked Questions

Q: How many outlets does the J08B0B have, and where are they located?

A: The J08B0B has eight outlets, all positioned on the rear of the unit. There are zero front-facing outlets. This rear-only layout keeps cabling routed to the back of the rack for cleaner cable management.

Q: What is the voltage and amperage rating of the J08B0B?

A: The J08B0B is rated for 120V AC at 15A — standard North American branch circuit spec. For continuous loads, stay at or below 12A (80% of rated capacity) per NEC guidelines.

Q: Is the J08B0B TAA compliant?

A: No. The J08B0B is not TAA compliant. It is not suitable for federal government projects or contracts requiring Trade Agreements Act compliance.

Q: How long is the power cord on the J08B0B?

A: The J08B0B includes a 6 ft (1.8 m) power cord, sufficient to reach a standard wall outlet or floor-level PDU from a typical rack position without an extension cord.

Q: Does the J08B0B include surge protection or a circuit breaker?

A: Surge protection and circuit breaker specifications are not confirmed in available evidence for the J08B0B. If power conditioning or overcurrent protection is a project requirement, verify with the manufacturer's current datasheet or pair this strip with a dedicated UPS or panel-level protection.

Q: What rack size does the J08B0B fit?

A: The J08B0B is a 1U rack-mount unit designed for standard 19-inch EIA equipment racks.

James Everett
James Everett

The J08B0B is the kind of component that doesn't get specced carefully enough until someone's standing in front of a finished rack trying to figure out why the cabling looks like a bird's nest. The rear-only outlet configuration — 0 front, 8 rear — is the right answer for any rack where you want a clean front panel and predictable cable routing to the back. I've seen plenty of integrators default to a cheaper front-outlet strip and regret it by the time the rack is commissioned.

Technical Highlights:

  • 6 ft Cord: Reaches a standard wall duplex or floor PDU from a typical rack position. Not a flex point — if your circuit is more than 6 ft away, address it at rough-in, not with a daisy-chained extension cord.
  • Master Switch: Single-switch power cut across all eight outlets. In a security rack running NVR, switch, and access panel, a clean simultaneous power cycle is faster and cleaner than hunting for individual plugs during a troubleshooting call.
  • 15A / 120V Rating: Standard branch circuit rating. Budget your load at 12A continuous max — with eight outlets filled, you'll hit that ceiling faster than you might expect if you're running PoE injectors or full-load NVRs alongside lighter accessories.

Deployment Considerations:

  • The TAA non-compliance is a hard stop for federal or GSA-schedule projects. Qualify the project before specifying this unit — swapping a power strip after rack installation is an avoidable callback.
  • All eight outlets switch together. If your deployment has any device that should NOT be power-cycled with the rest of the rack (e.g., a UPS, a managed switch with active sessions), either place that device on a separate always-on circuit or choose a selectively switched PDU instead.

The J08B0B is the right spec for commercial integrators building out security or AV racks on standard 15A North American circuits where rear cable management is a priority and TAA compliance is not a project requirement — think enterprise campus closets, retail back-of-house enclosures, and commercial building security head-end rooms.

Specifications
Mount Type: Rack
Cord Length: 6 ft (1.8 m)
Taa Compliant: No
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources