APC by Schneider Electric Rack PDU Basic 0U/1U 220-240V 32A (4) C19 Emea/asia - AP6032A

APC by Schneider Electric AP6032A Basic Rack PDU, 0U/1U, 32A, 200-240V, 4x C19OverviewThe AP6032A is a single-phase, basic rack power distribution uni…

$342.00 $229.99 SAVE $112
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU Basic 0U/1U 220-240V 32A (4) C19 Emea/asia - AP6032A

$342.00
$229.99

Overview

SKU: AP6032A
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP6032A Basic Rack PDU, 0U/1U, 32A, 200-240V, 4x C19

Overview

The AP6032A is a single-phase, basic rack power distribution unit rated at 32A and 200–240V — built for data centers, server rooms, and high-density rack environments in EMEA and Asia-Pacific regions where large-draw compute or storage equipment runs on IEC 60309 infrastructure. With four C19 outlets and a 7,680W load capacity, this PDU is sized for full-rack deployments where C20-plugged servers, high-wattage UPS output modules, or dense switch stacks need clean, reliable distribution from a single 32A circuit. The flexible 0U/1U form factor means you can mount it vertically in the zero-U space at the rear of the rack or horizontally in a standard rack unit slot — no wasted compute real estate either way.

Key Features

  • 32A Single-Phase Input via IEC 60309: The IEC 60309 input connector is the standard for high-current industrial and data center circuits in Europe and Asia. At 32A and 200–240V, the AP6032A supports up to 7,680VA/7,680W of connected load — enough headroom to drive four fully loaded C19 devices without approaching the 80% continuous-load threshold recommended for circuit protection.
  • Four C19 Outlet Configuration: C19 is the heavy-duty IEC connector (rated to 16A per outlet) used by enterprise servers, blade chassis PDU inputs, and high-end KVM switches. Four outlets is a deliberate count for high-density racks: fewer, higher-capacity connections reduce cable clutter and the risk of inadvertent disconnection compared to banks of C13 outlets.
  • 7,680W / 7,680VA Load Capacity: The matched watt and VA ratings confirm a unity power factor design at rated voltage — what you see is what you get in terms of real power delivery. No derating surprises when your power factor drops below 0.9.
  • 0U / 1U Flexible Mounting: Vertical zero-U mounting preserves all rack units for active equipment — a meaningful difference in fully populated 42U racks. The horizontal 1U option suits environments where side-mount cable channels are already occupied or where front-panel visibility matters for NOC staff during audits.
  • 3.65m Power Cord: The 3.65-meter input cable is long enough to reach floor-mounted power strips or overhead busway systems in most standard cabinet rows without requiring an extension — eliminates a common on-site improvisation that adds failure points.
  • 50–60 Hz Input Acceptance: The dual-frequency input handles both European 50Hz and some Asia-Pacific 60Hz grid standards from a single SKU — useful for organizations running multi-region data centers who want to standardize on one part number.
  • RoHS, CE, and VDE Certifications: CE marking confirms compliance with EU electrical safety directives for legal sale across the European Economic Area. VDE certification (Germany's rigorous electrical safety body) adds an independent third-party verification layer beyond self-declaration. RoHS compliance covers restricted substances — required for procurement in many EU public sector and enterprise programs.

Integration & Compatibility

The AP6032A fits standard 19-inch EIA racks via horizontal 1U mounting, or installs vertically in the zero-U channel on compatible APC NetShelter and third-party cabinets that provide side-mount PDU brackets. The C19 outlet type pairs directly with C20-plugged equipment — enterprise rack servers, UPS output sockets, and managed switches with IEC C20 inlet cords. This is a basic (non-metered, non-switched) PDU, meaning there is no network interface, no per-outlet switching, and no remote monitoring — power flows continuously from input to outlets. If per-outlet switching or energy monitoring is required, evaluate the AP78xx or AP86xx metered/switched families within the APC by Schneider Electric lineup instead. For environments deploying this unit alongside rack PDU infrastructure, plan circuit protection upstream — the unit itself has no integrated breaker on the individual outlet level. Pair with appropriately rated circuit breakers at the panel feeding the IEC 60309 inlet. Review your power planning requirements before committing to a non-monitored basic PDU at this load level, particularly if the facility's power management system requires branch-circuit-level data.

Frequently Asked Questions

Q: What plug type does the AP6032A use, and what does that mean for installation?

A: The AP6032A uses an IEC 60309 input plug — the blue industrial connector standard for high-current circuits in Europe and Asia. Your facility will need a matching IEC 60309 32A receptacle. This is not a standard Schuko or BS 1363 outlet; confirm your rack PDU circuit is wired accordingly before ordering.

Q: Can the AP6032A be mounted both horizontally and vertically?

A: Yes. The 0U/1U rating means it supports both orientations. Vertically (0U), it mounts in the zero-unit channel at the side or rear of compatible cabinets, preserving all rack units for active equipment. Horizontally (1U), it occupies one standard rack unit.

Q: Does the AP6032A provide remote monitoring or per-outlet switching?

A: No. The AP6032A is a basic PDU — it provides passive power distribution only. There is no network card, no per-outlet on/off control, and no energy metering. If those features are required, look at APC's metered or switched PDU families.

Q: What certifications does the AP6032A carry?

A: The AP6032A is CE marked, VDE certified, and RoHS compliant. CE covers EU electrical safety directives; VDE is an independent German safety certification with a higher verification standard than self-declaration; RoHS covers restricted hazardous substances required for EU procurement.

Q: What is the maximum load the AP6032A can handle?

A: The unit is rated at 32A input with a 7,680VA / 7,680W load capacity at 200–240V. In practice, size your connected load to no more than 80% of that (approximately 25.6A / 6,144W) for continuous operation per standard electrical safety practice.

Q: Is the AP6032A suitable for North American 120V deployments?

A: No. The AP6032A is rated 200–240V and uses an IEC 60309 input connector. It is designed for EMEA and Asia-Pacific deployments. North American 120V environments require a different PDU family.

Jerry Tildsen
Jerry Tildsen

The AP6032A sits in a specific niche that often gets underspecified: you need to distribute power to four high-draw C19 devices from a single 32A IEC 60309 circuit, and you don't need — or want — the cost and complexity of a managed PDU. At 7,680W rated capacity on a unity-power-factor design, there are no hidden derating gotchas when your servers dip below 0.9 PF under variable load.

Technical Highlights:

  • 7,680W / 7,680VA at Unity PF: The matched watt and VA figures mean APC is rating this at unity power factor — the full 32A x 240V is available as real watts, not apparent power. Competitors sometimes publish VA only, which can mislead when actual PF is 0.7–0.8.
  • IEC 60309 Input, 3.65m Cord: The 3.65-meter cord is generous enough for most raised-floor or overhead busway installations without field-cut extensions. IEC 60309 is the correct connector for this current class in EMEA — not a workaround.
  • VDE + CE + RoHS Stack: VDE is an independent third-party test, not a self-declaration. In EU public sector and regulated-industry data center procurement, VDE certification frequently appears on approved-vendor lists as a differentiator from CE self-certified alternatives.

Deployment Considerations:

  • This is a passive basic PDU — there is zero remote visibility into load, outlet status, or power events. If your data center management system (DCIM) needs branch-circuit-level data, you need a metered variant. Budget for that decision before the racks are live.
  • Four C19 outlets is the entire outlet count — no C13 outlets are present. Confirm all four devices use C20 inlet cords before installation. Mixed C13/C20 environments will need a different PDU model or a separate C13 strip downstream of a C19 output.

The AP6032A is the right call for a straightforward high-density rack in an EMEA colocation or enterprise data center where the upstream circuit is IEC 60309 32A, every connected device uses a C20 inlet, and operational simplicity outweighs the need for remote monitoring — particularly in budget-sensitive secondary rows where managed PDU costs aren't justified by the load profile.

Specifications
PDU types: Basic
Type: Single-phase
Rack capacity: 0U/1U
Mounting: Horizontal/Vertical
Product colour: Black
AC outlets quantity: 4 AC outlet(s)
Power plug: IEC 60309
AC outlet types: C19 coupler
Cable length: 3.65 m
Nominal input voltage: 200-240 V
AC input frequency: 50 - 60 Hz
Maximum current: 32 A
Nominal output voltage: 200-240 V
Load capacity: 7680 VA
Maximum input current per phase: 32 A
Maximum power: 7680 W
Compliance certificates: RoHS
Certification: VDE, CE
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources