APC by Schneider Electric Rack PDU Basic 0U/1U 100-240V/20A 220-240V/16A IEC 60320 C20;7 - AP6120A

APC by Schneider Electric AP6120A Basic Rack PDU, 0U/1U, 100-240V, 20A, 7-OutletOverviewThe APC by Schneider Electric AP6120A is a single-phase basic …

$228.00 $154.99 SAVE $73
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU Basic 0U/1U 100-240V/20A 220-240V/16A IEC 60320 C20;7 - AP6120A

$228.00
$154.99

Overview

SKU: AP6120A
UPC: 731304327851
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP6120A Basic Rack PDU, 0U/1U, 100-240V, 20A, 7-Outlet

Overview

The APC by Schneider Electric AP6120A is a single-phase basic rack power distribution unit designed for data centers, network closets, and security equipment racks where reliable, no-frills power distribution is the priority. Supporting 100–240V input at up to 20A (16A max input per phase), it delivers up to 3,680 VA/W of load capacity — enough headroom for dense rack deployments running mixed server, switch, and surveillance recorder loads. The AP6120A accepts a C20 inlet, making it compatible with the 20A locking cords already common in enterprise rack infrastructure, and distributes power across seven outlets in the C13/C19 format that matches the majority of rack-mount equipment today.

The 0U/1U dual-mounting design is a practical asset: install it vertically in the rack's zero-U space to preserve precious 1U slots, or mount it horizontally if your enclosure doesn't support vertical PDU channels. Either way, it fits standard 19-inch and 23-inch rack cabinets without modification. This is a APC by Schneider Electric core product built for straightforward deployment — no managed features, no network card, no complexity you don't need when your monitoring strategy already handles power at the UPS or switch level.

Key Features

  • 7 AC Outlets (C13 + C19): Seven IEC 60320 outlets cover the full range of rack equipment — C13 for standard 1U servers, switches, and IP cameras; C19 for higher-draw devices like UPS units and storage arrays. No need for C13-to-C19 adapters on mixed loads.
  • 20A / 100–240V Universal Input: The wide voltage window (100–240V) means this PDU works across North American, European, and international rack environments without rewiring. The C20 inlet handles 20A circuits, giving you full access to the load capacity of a standard 20A branch circuit — particularly useful when powering four or more PoE switches or NVRs simultaneously.
  • 3,680 VA Load Capacity: At 3,680W max, you have substantial overhead for demanding rack builds. Deploying a rack with dual 1U NVRs, a PoE switch, and supplemental storage? This PDU handles the aggregate draw without throttling. Always calculate your actual load at 80% of circuit capacity (16A effective) per NEC best practice.
  • 0U/1U Dual-Mount Flexibility: Mount vertically in zero-U space to keep all seven slots available for active equipment, or flip horizontal for cabinets without vertical PDU channels. The mounting choice doesn't change the electrical rating — both orientations deliver the same 20A/3,680W capacity, making this a good fit for rack PDU deployments across varying cabinet configurations.
  • IEC 60320 C20 Input Connector: The C20 locking inlet pairs with standard 20A IEC or NEMA L6-20P whips already stocked by most facilities teams. No proprietary connectors, no special-order power cords required in most cases.
  • 50–60 Hz Frequency Compatibility: Operates across both 50Hz and 60Hz grid frequencies. This matters for global integrators deploying standardized rack builds across multiple facilities in different countries — the same SKU ships everywhere.
  • Operating Range 0–50°C: Rated for operation from 0°C to 50°C, which covers sealed rack cabinets in warm machine rooms and edge deployments in non-climate-controlled IDF closets. At the upper end, verify rack airflow is adequate — passive PDUs don't generate meaningful heat, but they also don't help cool a poorly ventilated enclosure.
  • UL/C-UL, VDE, CE, RoHS Certified: Multi-region safety certifications (UL for North America, VDE for Germany/EU, CE for broader EU market) mean procurement and facilities teams won't face compliance objections in most enterprise environments. RoHS compliance is a baseline requirement for many government and enterprise purchasing programs.

Integration and Compatibility

The AP6120A is a basic (non-managed) PDU — there is no network interface, no remote switching, and no outlet-level monitoring. This is intentional for deployments where power management is handled upstream at the UPS or PDU management layer, and where cost and simplicity take priority over per-outlet telemetry. It integrates into any rack environment that uses standard IEC 60320 C13 or C19 equipment cords. No software, drivers, or firmware updates are required.

For deployments where you need remote monitoring, per-outlet switching, or environmental sensing, you would need to step up to a switched or metered PDU in the APC AP78xx or AP86xx series. The AP6120A fits where those features are redundant — branch circuits already protected and monitored at the panel or UPS level.

Security integrators stacking NVRs, PoE switches, and access control panels in a single rack will find the outlet mix practical: C13 for the bulk of equipment, C19 available for a UPS bypass or high-draw server. Pair this with a structured power protection strategy that includes upstream UPS runtime for the rack to avoid unplanned camera and recorder outages during brief power events.

Frequently Asked Questions

Q: What is the maximum load the AP6120A can handle?

A: The AP6120A is rated for up to 3,680 VA / 3,680W at 100–240V input. Per NEC guidelines, plan your actual connected load at no more than 80% of the 20A circuit capacity — effectively 16A continuous — to avoid tripping the branch circuit breaker under sustained load.

Q: Can the AP6120A be mounted both horizontally and vertically?

A: Yes. The AP6120A supports both 0U vertical mounting (in the side channel of the rack cabinet) and 1U horizontal mounting in a standard rack slot. The electrical rating and outlet count are identical in both orientations.

Q: What outlet types does the AP6120A provide?

A: The AP6120A has seven IEC 60320 outlets — a mix of C13 and C19 receptacles. C13 outlets accept standard rack equipment cords; C19 outlets handle higher-draw devices. The input uses an IEC 60320 C20 coupler (20A locking inlet).

Q: Does the AP6120A work on both 50Hz and 60Hz power grids?

A: Yes. The AP6120A is rated for 50–60 Hz input frequency, making it suitable for rack deployments in North America (60Hz) and international facilities (50Hz) without modification.

Q: Is the AP6120A a managed or monitored PDU?

A: No. The AP6120A is a basic PDU with no network interface, no remote switching, and no per-outlet metering. It distributes power passively. If outlet-level monitoring or remote switching is required, a stepped-up metered or switched PDU model would be needed instead.

Q: What certifications does the AP6120A carry?

A: The AP6120A is certified UL/C-UL (North America), VDE (Germany/EU), and CE (EU). It is also RoHS compliant, satisfying common procurement requirements for government and enterprise purchasing programs.

Jerry Tildsen
Jerry Tildsen

The AP6120A sits in a sweet spot that a lot of integrators overlook — the 20A basic PDU tier. When your branch circuit is already protected upstream by a smart UPS and you don't need per-outlet telemetry cluttering up your DCIM dashboard, this is the right call. The 3,680 VA load capacity with a C20 locking input means it's genuinely ready for a fully loaded 1U rack build — not just a light closet switch and a couple of cameras.

Technical Highlights:

  • 100–240V Universal Input: The wide input voltage range means you can standardize on one PDU SKU for both North American 120V/20A and international 230V installations. Fewer SKUs to stock, fewer procurement exceptions to manage.
  • 0U/1U Dual Mounting: The ability to go vertical in zero-U space is underused. In cabinets with zero-U PDU channels, you reclaim an entire 1U slot — that's often enough for a secondary NVR or an additional switch in a dense security rack.
  • UL/C-UL + VDE + CE Certification Stack: Three separate safety certifications on one unit simplifies compliance documentation for enterprise procurement teams. You're not chasing region-specific approvals for global rack rollouts.

Deployment Considerations:

  • The 16A max input per phase at 220–240V is the binding constraint in European deployments — not the 20A figure. Size your connected load accordingly, keeping aggregate draw below 16A on 240V circuits to stay within spec.
  • This is a passive, non-monitored PDU. If your rack design calls for outlet-level power metering — common on compliance-sensitive video surveillance racks that need audit trails of equipment uptime — the AP6120A is not the right model; plan for a metered variant instead.

The AP6120A is the right PDU for integrators building standardized security equipment racks — NVR, PoE switch, access control panel — where power monitoring is handled at the UPS layer and you need a reliable, multi-certified 20A distributor that won't eat rack space or add unnecessary management overhead.

Specifications
PDU types: Basic
Type: Single-phase
Rack capacity: 0U/1U
Mounting: Horizontal/Vertical
Product colour: Black
AC outlets quantity: 7 AC outlet(s)
Power plug: C20 coupler
AC outlet types: C13 coupler, C19 coupler
Nominal input voltage: 100-240 V
AC input frequency: 50 - 60 Hz
Maximum current: 20 A
Nominal output voltage: 100-240 V
Load capacity: 3680 VA
Maximum input current per phase: 16 A
Maximum power: 3680 W
Compliance certificates: RoHS
Certification: UL/C-UL, VDE, CE
Operating temperature (T-T: 0 - 50 °C
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources