Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The AP8887 is a Zero-U form-factor, metered rack power distribution unit rated at 17.3kW — built for three-phase power environments where rack space is at a premium and load visibility matters. Designed to mount vertically in the zero-U space at the rear of a standard rack, it leaves all standard rack units free for active equipment, a meaningful advantage in high-density data center rows or server rooms running out of 1U/2U slots for power management hardware.
The unit accepts 400V AC three-phase input and delivers 240V AC output, matching the power architecture common in European and international data center deployments as well as North American three-phase PDU infrastructure. The 6 ft input cord provides enough reach for most raised-floor or overhead busway configurations without requiring a cable extension.
The AP8887 belongs to APC's APC by Schneider Electric rack power lineup and fits facilities running three-phase power infrastructure in colocation, enterprise data centers, or security operation centers with high-density rack builds. It is not the right unit for single-phase branch circuits or North American 120V environments. For broader rack PDU selection guidance — including single-phase options, switched variants, and outlet-level control — review the full rack power distribution category. If your project requires a complete power strategy including UPS runtime planning, consult an uninterruptible power supply alongside this PDU.
Q: What is the input configuration of the AP8887?
A: The AP8887 accepts 400V AC three-phase input via its input cord. It is designed for three-phase power environments and is not compatible with single-phase branch circuits.
Q: What output voltage does the AP8887 deliver?
A: The AP8887 delivers 240V AC output to connected equipment. Verify that all devices in your rack accept 240V input before deploying.
Q: How does the Zero-U form factor work?
A: Zero-U PDUs mount vertically in the dedicated zero-U space along the rear vertical rail of a standard rack, consuming no standard rack units. The AP8887 measures 72.0
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →