Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The AP8453 is a 2nd-generation Zero-U rack PDU from APC by Schneider Electric designed for high-density server and network equipment racks in data centers, telecom closets, and enterprise machine rooms. It delivers 32A at 230V across 24 total outlets — 21 IEC C13 and 3 IEC C19 — with per-outlet metering that gives you actual consumption data at the socket level, not just aggregate draw at the input. That granularity matters when you're capacity-planning a densely loaded rack or tracking power allocation per tenant in a colocation environment. The Zero-U form factor mounts vertically in the side channel of a standard rack power distribution installation, so it claims no usable rack unit space — a genuine advantage when every U counts.
The AP8453 integrates with APC's EcoStruxure IT infrastructure management platform and is compatible with APC's Network Management Card ecosystem for remote monitoring, alerting, and control. The CAN bus port supports daisy-chaining multiple PDUs under a single management card, reducing per-outlet licensing overhead in high-density rows. For environments running third-party DCIM or BMS platforms, SNMP and Modbus connectivity (via the Network Management Card) allow integration with most enterprise monitoring stacks. Refer to APC's compatibility matrix for NMC card options — the rack PDU category includes compatible accessories. For broader power planning in rack deployments, reviewing a power protection strategy before specifying circuit feeds is recommended.
Q: What is the maximum power capacity of the AP8453?
A: The AP8453 is rated for 32A at 230V, which translates to a maximum capacity of approximately 7.36kW. Real-world loading should be kept at or below 80% of rated capacity (roughly 5.9kW) per standard electrical practice to avoid nuisance tripping.
Q: Does the AP8453 support remote outlet switching?
A: The AP8453 is a metered-by-outlet PDU, not a switched PDU. It provides per-outlet power consumption data but does not support remote on/off control of individual outlets. If remote switching is required, a different model in APC's 2G Switched PDU line would be the correct choice.
Q: What does the Zero-U form factor mean for rack installation?
A: Zero-U means the PDU mounts vertically in the side channel of the rack rather than occupying horizontal rack units. The AP8453 measures 72 inches long x 2.2 inches wide x 2.0 inches deep, designed to fit behind cable management in standard 42U or taller racks without consuming usable equipment space.
Q: What is the CAN Port Terminator included in the box used for?
A: The CAN bus port enables daisy-chaining multiple 2G PDUs under a single APC Network Management Card. The CAN Port Terminator must be installed on the last PDU in the chain to properly terminate the bus. If you're installing a single standalone unit, the terminator still needs to be installed on that unit's CAN port.
Q: What outlet types does the AP8453 provide?
A: The AP8453 provides 21 IEC 320 C13 outlets (standard for 1U/2U servers and networking gear) and 3 IEC 320 C19 outlets (for high-draw equipment with C20 plugs, typically rated up to 16A per outlet). Total outlet count is 24.
Q: Is a network management card included with the AP8453?
A: Based on available product documentation, a Network Management Card is not included in the box with the AP8453. The unit ships with the PDU, CAN Port Terminator, mounting brackets, serial configuration cable, installation guide, and safety guide. Network management capability requires a separately purchased APC Network Management Card.

The AP8453 is the PDU I'd specify for a high-density 230V rack where per-outlet visibility is a hard requirement — not a nice-to-have. The 32A input and 24-outlet layout (21x C13, 3x C19) cover a fully loaded compute row without forcing outlet adapters into the mix, and the Zero-U vertical mount keeps the 72-inch unit completely out of the equipment space.
Technical Highlights:
Deployment Considerations:
This PDU is the right call for enterprise data centers and colocation deployments running 230V power infrastructure where accurate per-outlet consumption tracking is required for capacity planning or tenant billing — not for 120V North American deployments, which require a different model entirely.