Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5X-72VBAT GXT5 72V UPS Replacement Battery Pack

Overview

The Vertiv PBRGXT5X-72VBAT is a 72V replacement battery pack engineered specifically for the Liebert GXT5-3000LVRT2UXL 3000 VA line-interactive UPS platform. When your GXT5's runtime degrades — a natural outcome of battery chemistry aging over a 3–5 year service cycle — swapping in this factory-matched pack restores the runtime envelope your site was designed around, without replacing the entire UPS chassis. For data closets, edge compute rooms, and critical AV or security infrastructure where the GXT5 is the power anchor, this is the correct part to keep on the shelf or schedule into a planned maintenance window.

The PRO Refresh Plus designation on the PBRGXT5X-72VBAT indicates this SKU bundles a two-year service agreement (BAS2YR) alongside the physical battery replacement, giving facilities teams a documented support path — not just a box of cells.

Key Features

  • 72V Battery Architecture Matched to the GXT5-3000LVRT2UXL: The 72V string is sized to the 3000 VA load rating of the host UPS. Using an off-brand or mismatched voltage pack risks float charge errors or BMS faults that can leave you without protection during an actual outage — the PBRGXT5X-72VBAT eliminates that compatibility risk by design.
  • PRO Refresh Plus Service Bundle (BAS2YR): The two-year Vertiv PRO Refresh Plus agreement bundled with this SKU covers labor and parts for battery-related service calls. For enterprise deployments where sending a tech on-site is a budget line item, having the service contract co-purchased with the battery simplifies procurement and ensures the replacement is performed under a documented SLA.
  • Drop-in Replacement for the GXT5 Platform: The PBRGXT5X-72VBAT installs into the existing GXT5-3000LVRT2UXL chassis without modifications. Rack-mounted UPS battery swaps in 2U form factors are time-sensitive — a plug-compatible replacement means less planned downtime and no improvised wiring during a maintenance window.
  • Genuine Vertiv Replacement Part: Factory-new cells sourced through the Vertiv supply chain — not refurbished, not third-party equivalents. Battery authenticity matters for BMS handshake protocols on managed UPS units; counterfeit or grey-market cells may not communicate correctly with the GXT5's battery monitoring circuit, leading to inaccurate runtime estimates on your UPS dashboard.
  • Supports Continued Runtime for 3000 VA Loads: The GXT5-3000LVRT2UXL is rated for 3000 VA / 2700W loads. Restoring a degraded battery to specification means your runtime calculations — whether for a 5-minute graceful shutdown or a 15-minute bridging window — are accurate again. A worn pack may report 80% capacity while delivering 40% actual runtime under load.
  • Planned Maintenance Compatibility: Designed for scheduled battery refresh cycles. Most UPS manufacturers recommend battery replacement every 3–5 years under normal operating conditions. Having the PBRGXT5X-72VBAT on hand before the end-of-life threshold keeps a replacement cycle from becoming an emergency procurement.

Integration & Compatibility

The PBRGXT5X-72VBAT is verified compatible with the Liebert GXT5-3000LVRT2UXL (3000 VA) UPS system. Do not attempt to install this battery pack in other GXT5 VA ratings or in non-GXT5 Liebert platforms — voltage string mismatches can damage the UPS inverter or charger circuit. If your site runs the 1000 VA or 2000 VA GXT5 variants, a different battery SKU is required. Confirm your UPS model number on the rear label before ordering. The PBRGXT5X-72VBAT (often searched as PBRGXT5X 72VBAT) is the correct replacement for the -3000LVRT2UXL model specifically.

For broader infrastructure context, this battery pack fits within the Vertiv power protection line, which covers UPS systems, power distribution, and thermal management for data center and edge deployments. If you are evaluating battery runtime requirements for a new installation, see the UPS and power protection category for compatible Liebert GXT5 units. For sites running rack-mounted security equipment — NVRs, access control servers, or VMS appliances — pairing a GXT5 UPS with a managed PoE switch on a separate UPS circuit is a common architecture for maintaining camera uptime during power events. A power planning guide can help right-size runtime budgets across mixed loads.

Frequently Asked Questions

Q: Which UPS model is the PBRGXT5X-72VBAT compatible with?

A: The PBRGXT5X-72VBAT is designed specifically for the Liebert GXT5-3000LVRT2UXL 3000 VA UPS system. It is not cross-compatible with other GXT5 VA ratings or non-GXT5 Liebert platforms. Verify your UPS model number before ordering.

Q: What does the PRO Refresh Plus (BAS2YR) service designation include?

A: The BAS2YR suffix indicates a two-year Vertiv PRO Refresh Plus service agreement is bundled with this SKU. This covers Vertiv-supported battery service for the replacement period. Contact Vertiv directly to confirm specific SLA terms for your region.

Q: Can I install the PBRGXT5X-72VBAT myself, or is a technician required?

A: Battery replacement procedures vary by UPS model. The GXT5-3000LVRT2UXL is a rack-mounted unit; while the battery module is designed for serviceability, the bundled BAS2YR service agreement provides access to Vertiv-supported installation. Check the GXT5 service manual and local safety regulations — working inside a live UPS carries electrical hazard risks.

Q: How often should the battery in a GXT5-3000LVRT2UXL be replaced?

A: UPS battery service life is typically 3–5 years under normal operating conditions (20–25°C ambient). High ambient temperatures accelerate degradation. Most facilities schedule a battery refresh at the 3-year mark to avoid runtime shortfalls before the next planned maintenance window.

Q: Will a third-party 72V battery work in the GXT5-3000LVRT2UXL instead of the PBRGXT5X-72VBAT?

A: Third-party batteries may not communicate correctly with the GXT5's battery management system, resulting in inaccurate runtime estimates or BMS fault alerts. Vertiv recommends using genuine replacement parts for BMS handshake integrity and warranty compliance. Using non-OEM batteries may also void the UPS warranty.

Q: Is the PBRGXT5X-72VBAT in stock and ready to ship?

A: Stock and availability are shown in real time on this page. For lead time on volume orders or planned maintenance schedules, contact the pre-sales team for a same-day quote.

Jerry Tildsen
Jerry Tildsen

The PBRGXT5X-72VBAT is a straightforward but operationally important part — it restores the 72V battery string in the GXT5-3000LVRT2UXL to factory specification, which is the only way to get back to accurate runtime numbers after the original cells have aged out. I have seen sites run degraded UPS batteries for 18 months past their service window because procurement treated a battery replacement as a non-urgent ticket — until they had an actual outage and discovered their 10-minute runtime budget had shrunk to under 2 minutes under a 2400W rack load.

Technical Highlights:

  • 72V Compatibility Lock: The 72V string is the exact specification for the 3000 VA GXT5 variant — not interchangeable with the lower-voltage strings used in the 1000 VA or 2000 VA models. Getting this wrong means float charge mismatches and potential BMS errors on the host UPS.
  • BAS2YR Service Bundle: The two-year PRO Refresh Plus agreement co-packaged with this SKU simplifies what is otherwise a multi-PO process — battery hardware and labor coverage in one line item. Useful for managed service providers billing clients on a per-device maintenance contract.
  • Genuine Replacement Cell Integrity: BMS handshake protocols on the GXT5 platform depend on cell authentication. Factory-new Vertiv cells are the only reliable way to ensure the UPS management card reports accurate state-of-charge and runtime estimates rather than throwing a battery fault that pages your NOC at 2 AM.

Deployment Considerations:

  • Confirm the exact UPS model label before ordering — the -3000LVRT2UXL suffix is load-bearing. A GXT5 at a different VA rating uses a different battery SKU, and the 72V pack will not transfer between variants.
  • If the host UPS has been running a degraded battery for over 12 months, run a full self-test immediately after PBRGXT5X-72VBAT installation to establish a new runtime baseline before relying on the UPS for a real outage scenario.

This replacement battery is the right scheduled-maintenance part for facilities running the GXT5-3000LVRT2UXL as the power anchor for edge server rooms, security operations centers, or rack-dense IDF closets where a runtime shortfall during a power event is a business continuity problem, not just an inconvenience.

Specifications
Compatibility: Liebert GXT5-3000LVRT2UXL (3000 VA) UPS Systems
Type: UPS Battery Pack
Manufacturer Website Address: http://www.vertiv.com/
Product Name: GXT5 72V UPS Replacemet Battery
Q&A
Reviews

Vertiv GXT5 72VBAT - PBRGXT5X-72VBAT

$3,899.00
$2,673.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources