UPS & Power Management
Showing Results for UPS & Power Management
-
CyberPower
SKU: BP36V60ART2U
CyberPower UPS Smart APP XL Battery Module 1-1.5 KVA Online UPS 20 12V-9AH 2U
In stock · Ships same business day$1,055.00 $887.99 Save $167.01 -
CyberPower
SKU: BP72V60ART2U
CyberPower UPS Smart APP XL Battery Module 2-3 KVA Online UPS 20 12V-9AH 2U
In stock · Ships same business day$1,352.00 $1,138.99 Save $213.01 -
CyberPower
SKU: BPL48V75ART2U
CyberPower UPS Smart APP XL Battery Pack UPS Systems (12)12V/9AH
$1,254.00 $1,228.99 Save $25.01 -
Eaton
SKU: 5P1000R
Eaton 5P 1000VA 770W 120V Line-Interactive UPS 5-15P - 5P1000R
- 1000VA / 770W line-interactive UPS with AVR
- Automatic voltage regulation responds to sags and surges
- Supports up to 5 networked devices at typical load
In stock · Ships same business day$1,106.00 $926.99 Save $179.01 -
Eaton
SKU: 103003055
Eaton Industrial Relay Card - 103003055
- Industrial relay card for Eaton control platforms
- Modular relay expansion isolates load switching from logic
- Reduces electromagnetic interference on main control board
$580.00 $450.99 Save $129.01 -
Eaton
SKU: 103006348-001
Eaton Kit (Harness Extention ERM to UPS) - 103006348-001
- Harness extension kit for ERM module to UPS cable runs
- Adds reach when standard cable run is insufficient
- Preserves ERM connectivity for distant rack placement
$348.00 $271.99 Save $76.01 -
Eaton
SKU: 124100028-001
Eaton Powerware 9355 UPS (20 and 30kVA 3-Breaker - 124100028-001
- 3-breaker maintenance bypass for Powerware 9355 20/30kVA
- Controlled transfer between utility, load, and UPS isolation
- Service UPS without interrupting downstream load
$7,940.00 $5,139.99 Save $2,800.01 -
ELK Products
SKU: ELK-12180
ELK Products ELK-12180 12V 18Ah Lead Acid UPS Battery
12V 18Ah lead acid battery for security system backup power
- 12V 18Ah lead-acid UPS battery - 900 Wh stored energy reserve
- 20-hour rate sustains door strikes, maglocks, and panel displays
- 11.44 lb cell fits standard security and UPS enclosure trays
$97.74 $61.99 Save $35.75 -
ELK Products
SKU: ELK-BLT
ELK Products ELK-BLT Battery Backup Accessory
Battery backup with LifeTester health monitoring for ELK panels
- Battery backup tester with LifeTester predictive health monitoring
- Predicts remaining battery runtime before in-field failure
- Padded carrying case and self-adhesive test data labels included
$243.57 $204.99 Save $38.58 -
HES
SKU: B-24-5
HES B-24-5 24VDC 5AMP Battery Backup Power Supply
24VDC 5AMP battery backup for access control systems during outages
- Maintains 24VDC @ 5AMP continuous output to door locks and readers
- Compact battery backup module rated for equipment enclosures and racks
- Compatible with HES electric strikes and magnetic lock installations
$213.00 $212.99 Save $0.01 -
i-PRO
SKU: MR-BAT-8C
i-PRO MR-BAT-8C Battery Backup Unit for MR-8C
Battery backup for i-PRO MR-8C mobile NVR during power sags and engine cranking
- Seamless power transition protects against voltage drops and recording interruptions
- Runtime allows controlled shutdown to prevent video buffer loss and database corruption
- Mounting kit included for secure installation in vehicle surveillance systems
$2,088.00 $1,407.99 Save $680.01 -
Kantech
SKU: KT-BATT-1212
Kantech 12V 12Ah Rechargeable Battery
12V 12Ah rechargeable battery for Kantech access control backup power
- 12V 12Ah sealed lead-acid backup battery (144 Wh)
- Sustains access panels during multi-hour utility outages
- Standard form factor for Kantech control hardware
$67.00 $53.99 Save $13.01 -
Kantech
SKU: KT-BD7-12
Kantech KT-BD7-12 12V 7Ah Rechargeable Battery Pack
12V 7Ah rechargeable battery pack, 5-unit set for access control backup
- 12V 7Ah sealed lead-acid rechargeable battery pack
- Pack of 5 units for bulk multi-panel backup
- Standard 12V backup battery format for security systems
$170.00 $134.99 Save $35.01 -
Lifesafety Power
SKU: FPO150-2D8E8S
Lifesafety Power FPO150-2D8E8S Software House UPS 120 VAC 150W
- 150W UPS keeps access control readers and door locks live during mains failure.
- 16 auxiliary outputs power multiple device classes from one battery-backed source.
- 120 VAC input integrates directly into Software House Unified Power Systems.
$1,901.00 $1,248.99 Save $652.01 -
-
UPS & Power Management
Uninterruptible power supplies and rack-mount power distribution for network and surveillance infrastructure. Online and line-interactive UPS models with SNMP management protect against outages and power quality issues.
Plan Your Deployment
- Calculate total VA/watt load from all connected networking and recording equipment
- Specify required battery runtime for graceful shutdown or ride-through
- Evaluate online vs. line-interactive topology for power quality needs
- Confirm rack-mount form factor and outlet count for your cabinet
UPS & Power Management — Engineering-Grade UPS & Power Management for Commercial Deployments
This category covers 4 working models of ups & power management sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
UPS topology dictates power quality during normal operation and transfer behavior during failure. Standby (offline) units switch to battery on AC failure — cheapest, with brief transfer time acceptable for cameras and switches. Line-interactive units regulate voltage and absorb sags without going to battery, extending battery life. Double-conversion online UPS deliver clean, constantly-regenerated AC — required for sensitive analytical equipment and ideal for critical NVRs.
Runtime is a function of load (watts) and battery capacity (Wh). A 1000VA UPS at 500W load runs 5-8 minutes on internal batteries — enough for graceful shutdown but not extended operation. Extended battery packs add hours. Calculate actual runtime requirement based on average utility outage duration in your area and the device's recovery behavior on power restoration.
Form factor and outlet count drive rack-vs-tower choice and circuit-breaker sizing. Tower UPSs serve standalone NVRs or desktop workstations. 1U-4U rack UPSs serve data closets and rack-mounted equipment. Look at the input plug type (NEMA 5-15, L5-30, L6-30) and confirm the building circuit supports the UPS rating; over-large UPSs on under-sized circuits trip breakers during charging.
Network management cards (APC AP9640, Eaton X-Slot) provide SNMP monitoring, email alerts, and integration with VMS or facility management software. For critical sites, this is essential — silent UPS failure leaves you blind until the next outage exposes it. Schedule annual self-tests through the management interface and replace batteries every 3-5 years as a preventive measure.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP20 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Power Supply |
Top Brands in This Category
Frequently Asked Questions
What size UPS do I need for an 8-camera NVR?
For an 8-camera NVR drawing about 100-150W and a small PoE switch at 200W, plan for a 1000-1500VA UPS to support 15-30 minutes of runtime. That covers most utility outages and gives ample time for graceful shutdown if power doesn't return. For sites with frequent or extended outages, scale to 2000VA+ with an extended battery pack.
How long does a UPS battery last?
Sealed lead-acid (SLA) UPS batteries typically last 3-5 years. Lithium-ion UPS batteries (newer, more expensive) last 8-10 years. Heat is the primary aging factor — UPSs in unconditioned closets fail batteries faster. Schedule replacement at year 3 for SLA and year 7 for lithium, regardless of self-test results; runtime degrades silently and slowly before complete failure.
Should I use a UPS or a generator for backup power?
UPSs cover seconds-to-minutes outages and bridge to generator startup. Generators cover hours-to-days outages but take 10-30 seconds to come online. For sites that need uninterrupted operation through extended outages, both are required: UPS bridges the generator startup gap and conditions generator power, generator covers the long tail. Standalone UPS without generator works for most commercial sites where occasional brief outages are acceptable.
Can one UPS power my entire camera system?
For small sites (8-16 cameras, single NVR, one switch) — yes, a single UPS works. For larger sites, distribute UPS protection across multiple smaller units rather than one large UPS. Reasons: failure isolation (one UPS battery failure doesn't take down everything), shorter cable runs from UPS to load (avoids voltage drop), and runtime calculation simplicity per zone.
What's the difference between line-interactive and online UPS?
Line-interactive UPSs run on utility power normally and switch to battery on failure. They include voltage regulation (AVR) that absorbs sags and surges without battery use. Online (double-conversion) UPSs continuously regenerate AC from battery-rectified DC — perfect output regardless of input quality. Online UPSs cost 2-3x more and are appropriate for highly sensitive loads (servers, lab equipment) or sites with very poor utility power.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.