Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit U03N14L SteadySine 3KVA 120V Uninterruptible Power Supply

Overview

The Panduit U03N14L is a 3KVA, 120V uninterruptible power supply from the SteadySine™ product line, engineered for data center, edge computing, and enterprise micro-datacenter (MTDC) environments. At 3U height (3.41"/86.5mm) and 17.3" wide, it fits standard 19-inch rack enclosures without consuming excessive rack space — a real consideration when every rack unit costs money in dense deployments. The U03N14L carries Panduit's SteadySine™ designation, indicating a pure sine wave output topology suited for sensitive electronic loads that regulated switching power supplies and active PFC equipment demand.

Key Features

  • 3KVA SteadySine™ Pure Sine Output: Sensitive server and networking loads with active PFC power supplies require a clean sine wave during battery operation. The SteadySine™ topology delivers that — line-interactive or online double-conversion UPS designs that output modified sine wave can cause equipment instability or reduced battery life in servers with modern power supplies.
  • 120V Input/Output: Configured for North American 120V infrastructure — aligns with standard branch circuit distribution in US data center and edge deployments without step-down transformers or special wiring.
  • 3U Rack Form Factor (3.41"/86.5mm H × 17.3" W): Fits standard EIA 19-inch rails. At 3U, it occupies predictable rack real estate. Plan rack layouts accordingly — bottom-of-rack mounting is preferred for weight distribution in high-density cabinets.
  • Data Center, Edge, and MTDC Application: Panduit positions the U03N14L across data center core, edge nodes, and enterprise MTDC deployments — meaning the design handles both the thermal and power cycling demands of always-on infrastructure, not just occasional-use IT closets.
  • Panduit SteadySine™ Product Line: The Panduit power infrastructure line is built around physical infrastructure for professional data center and enterprise environments. Pairing this UPS with structured power distribution and rack PDUs from the same ecosystem simplifies commissioning and support.

Integration & Compatibility

The U03N14L is designed for rack integration within standard 19-inch cabinets. As part of UPS and power protection planning for edge or MTDC builds, pair it with appropriately rated rack PDUs and ensure branch circuit breaker ratings match the 3KVA load capacity. For data center power planning, consult runtime and load curves from the manufacturer spec sheet before finalizing battery backup duration requirements — Panduit's product page for this SKU contains full runtime tables not reproduced here. Communication interface options (SNMP, USB, dry contact) should be confirmed against the manufacturer datasheet for integration with your power management platform.

Frequently Asked Questions

Q: What does the SteadySine™ designation mean for the U03N14L?

A: SteadySine™ is Panduit's sub-brand for pure sine wave UPS products. This means the U03N14L outputs a clean sine waveform during battery operation, which is required by servers and networking equipment with active PFC (Power Factor Corrected) power supplies. Equipment with active PFC can malfunction or sustain damage when powered by modified sine wave UPS units.

Q: What rack form factor does the U03N14L fit?

A: The U03N14L measures 3.41 inches (86.5mm) in height and 17.3 inches (440mm) in width, fitting standard 19-inch EIA rack enclosures in a 3U footprint.

Q: What environments is the U03N14L designed for?

A: Panduit specifies the U03N14L for data center, edge computing, and enterprise micro-datacenter (MTDC) deployments — environments with always-on uptime requirements and sensitive electronic loads.

Q: What is the power capacity of the U03N14L?

A: The U03N14L is rated at 3KVA at 120V. Actual watt capacity depends on the power factor rating; consult the manufacturer's datasheet for VA-to-watt conversion and load derating curves.

Q: Can the U03N14L be integrated with a power management system?

A: Communication interface availability (SNMP card, USB, dry contact) should be confirmed directly from the Panduit product specification sheet for this SKU, as the available evidence does not enumerate specific interface options.

Jerry Tildsen
Jerry Tildsen

The U03N14L sits in a segment where the UPS topology decision — pure sine vs. modified sine — is genuinely consequential. Panduit's SteadySine™ designation confirms pure sine wave output, and at 3KVA/120V in a 3U rack package, this unit is sized for the branch circuit loads you typically see on individual server rows or edge compute nodes rather than full room-level distribution.

Technical Highlights:

  • 3KVA Capacity: Appropriately sized for a loaded 1U/2U server shelf or a small network equipment stack — enough headroom that you are not running the UPS near its ceiling under normal operation, which extends battery cycle life.
  • Pure Sine Wave (SteadySine™): Modern servers with active PFC power supplies — effectively everything shipping today from major OEMs — require a true sine wave source during battery operation. Modified sine wave UPS units can trigger PFC instability that causes premature shutdown or power supply damage. This spec is non-negotiable for production server loads.
  • 3U × 19-inch Rack Form Factor (3.41" H × 17.3" W): Slots into standard rack infrastructure without adapters. At 3U, position it at the bottom of the rack to keep the center of gravity low — particularly relevant in seismically braced MTDC deployments.

Deployment Considerations:

  • The product name includes 'L' indicating a locking-style outlet or input connector configuration — verify the specific NEMA receptacle type from the Panduit datasheet before ordering to confirm compatibility with your existing branch circuit wiring and PDU cords.
  • Runtime tables are not available in the current evidence set. Before finalizing battery backup duration requirements for your deployment, pull the manufacturer's runtime curves — 3KVA units vary significantly in runtime at partial vs. full load, and MTDC environments often have tighter runtime SLAs than general IT closets.

The U03N14L is the right fit for edge rack deployments and enterprise MTDC rows where pure sine wave output, standard 19-inch integration, and a Panduit physical infrastructure ecosystem are already committed — particularly builds where matching the UPS vendor to the rack PDU and cable management vendor simplifies the support contract.

Specifications
Sub Brand: SteadySine™
Application: Data Center, Edge, Enterprise MTDC
Height In: 3.41
Height Mm: 86.5
Width In: 17.3
Width Mm: 440
Product Type: UPS
Carton Qty: 0
Package Qty: 1
Upc: 61305689895
Cable Category: power-distribution-environmental-connectivity-hardware
Type: UPS
Q&A
Reviews
Have Questions?

Panduit SS O-ldc UPS 3KVA L 120V NC PK1

$6,683.66
$3,898.99

RELATED PRODUCTS

Save $386.21
Panduit Steadysine On-line Double Conversion UPS, 3KVA, Vrla, 120V, NC
Add to Cart The item has been added

Panduit U03N11V

Panduit Steadysine On-line Double Conversion UPS, 3KVA, Vrla, 120V, NC

3KVA online double-conversion uninterruptible power supply from the SteadySine™ line, designed for data center, edge, and enterprise micro-datacenter

    Usually Ships in 2-3 Weeks Free shipping over $499
    $2,183.20 $1,796.99 Save $386.21
    The item has been added Add to quote
    $2,183.20 $1,796.99 Save $386.21
    Save $386.21 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources