Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit PR2VSD12 PatchRunner 2 Vertical Dual-Sided Cable Manager

The Panduit PR2VSD12 PatchRunner 2 vertical cable manager delivers dual-sided, ultra-high-density cable routing in a 12-inch footprint, freeing critical floor space in colocation and enterprise data centers. Pre-assembled with a metal backbone, molded plastic fingers, and a full-length dual-hinging door, this 45RU manager mounts between standard 19" or 23" EIA racks to organize fiber and copper patch cables without the maintenance burden or floor-space penalty of traditional horizontal overhead cable trays. For integrators managing high-density switch fabrics, SAN arrays, or top-of-rack Ethernet deployments, the PR2VSD12's combination of dual-sided access, pre-assembled construction, and lockable metal door eliminates the cable-management bottleneck that limits rack density in space-constrained server rooms.

Key Features

  • Dual-sided design with independent finger sets on both faces maximizes cable capacity per square foot of floor space, enabling shared cable management between back-to-back rack rows
  • Pre-assembled metal backbone eliminates field assembly time, reducing deployment from 45 minutes per unit to under 15 minutes and cutting total cost of ownership
  • Full-length metal door with dual-hinge, push-to-close latching provides secure access from either side without fumbling with cam locks during maintenance windows
  • Molded plastic fingers protect cable jackets from sharp edges while maintaining bend-radius compliance for 10Gb/40Gb copper and fiber installations
  • 45RU height (83.88 inches) matches full-height racks for seamless integration in standardized data halls and colocation cages
  • 12-inch width balances high capacity with aisle clearance requirements, consuming 50% less floor space than traditional 18-inch-wide managers
  • UL 2416 and CSA C22.2 listed for North American commercial installations requiring fire and electrical safety code compliance
  • RoHS compliant for procurement environments with hazardous-substance restrictions, including federal contractors subject to FAR and state/municipal environmental policies

The PR2VSD12 uses a welded steel backbone frame with dual rows of flexible, molded plastic fingers that accept patch cables from both rack faces. Each finger set is independently accessible, allowing technicians to add or remove cables from the front or rear without disturbing the opposite side—critical in live environments where a single accidental pull can bring down a production circuit. The metal door spans the full 45RU height and features a dual-hinge design: it swings open from either the left or right edge, then secures with a push-to-close magnetic latch that eliminates fumbling with traditional cam locks or key latches during maintenance windows. The door's metal construction provides electromagnetic shielding and physical protection, keeping cable plant secure in multi-tenant colocation cages or access-controlled server rooms where physical security audits require lockable infrastructure.

The manager's 12-inch width strikes a balance between capacity and aisle clearance. In a typical 42-inch-wide hot-aisle/cold-aisle layout, a pair of PR2VSD12 units mounted between facing racks consumes 24 inches of the total 42-inch clearance, leaving 18 inches of working space—enough for a technician with a laptop cart to perform moves, adds, and changes without blocking the aisle. This is a 50% floor-space reduction compared to traditional 18-inch-wide managers, and the dual-sided design delivers equivalent or greater cable capacity by using both rack faces instead of only the cold-aisle side. Panduit ships the PR2VSD12 fully assembled in a single carton. There are no bags of screws, no finger strips to snap into place, and no door alignment procedures. You mount the unit to the rack uprights using standard #12-24 cage nuts (not included), route your cables, and close the door. This cuts deployment time from 45 minutes per manager (typical for field-assembled units) to under 15 minutes, and it eliminates the risk of missing hardware or misaligned finger strips that create snag points during cable pulls.

The PR2VSD12 is designed for high-density patch environments: top-of-rack Ethernet switches with 48+ ports, SAN fabrics with dense fiber arrays, or IP-based KVM installations where every server has a dedicated network and management connection. In a 45RU rack populated with ten 4-post servers and associated networking gear, you might have 200+ patch cables running between devices, switches, and cross-connects. Without vertical managers, those cables either drape across the front of the equipment (blocking airflow and obscuring status LEDs) or get zip-tied into ad-hoc bundles that make individual cable tracing nearly impossible. The PR2VSD12 gives every cable a defined path from device to manager, maintaining bend-radius compliance and enabling visual tracing even in racks with 10Gb or 40Gb cable densities. The dual-sided design is especially valuable in back-to-back rack rows with shared infrastructure. Mount a PR2VSD12 between two racks, and each rack gets its own dedicated finger set. Rack A's cables exit the rear of the equipment, pass through the manager's front-side fingers, and terminate at patch panels or cross-connects. Rack B's cables do the same on the manager's rear-side fingers. This eliminates the need for separate managers on each rack, cutting hardware cost by 50% and freeing up rack-U space for revenue-generating equipment.

In multi-tenant colocation environments, the lockable door (compatible with standard cam locks or padlocks via the integrated hasp) provides an additional layer of physical security. Customers can cage their racks but leave the cable managers outside the cage for facility-managed cross-connects, and the locked door prevents unauthorized access to live circuits. In enterprise data centers, the door keeps cable plant clean and professional-looking during audits or executive tours, without the need for separate cable-shrouding or curtain systems. The PR2VSD12 meets UL 2416 (the standard for power and communications wiring systems) and CSA C22.2, ensuring it complies with fire and electrical safety codes in U.S. and Canadian jurisdictions. For integrators managing high-density fiber or copper installations in space-constrained data centers, the PR2VSD12's combination of dual-sided capacity, pre-assembled construction, and full-height door coverage makes it the right choice when floor space costs more than hardware, and cable plant quality directly impacts uptime SLAs.

Specifications
Product Type: Dual-Sided Vertical Cable Manager
Series: PatchRunner 2
Rack Compatibility: 45RU 19"/23" EIA Rack
Height: 83.88 in (2130.4 mm)
Width: 12 in (304.8 mm)
Color: Black
Construction: Metal backbone with molded plastic fingers
Door Type: Full-length metal, dual-hinging, push-to-close
Door Configuration: 1 door
Package Quantity: 1
Standards: UL 2416, CSA C22.2
Environmental Compliance: RoHS Compliant
UPC: 61305639581
Manufacturer: Panduit
MPN: PR2VSD12
Type: Vertical Cable Manager
Sub Brand: PatchRunner™ 2
Height In: 83.88
Height Mm: 2130.4
Width In: 12
Width Mm: 304.8
Carton Qty: 0
Package Qty: 1
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit PR2VSD12 45RU Dual-Sided Vertical Cable Manager

$2,446.38
$1,584.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources