SKU: F8RNM5ENNABM030
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit F8RNM5E5EANM050 is a pre-terminated OS2 singlemode trunk cable assembly carrying 864 fibers across 50 meters (164.1 ft) via MPO Female connectors. At this fiber count, it targets high-density fiber optic infrastructure scenarios — specifically data center main distribution areas (MDAs), entrance facilities, and telecommunications rooms where a single conduit run must deliver massive parallel bandwidth capacity. Pre-termination eliminates field-splicing labor and the splice-loss variability that comes with it, which matters when you're commissioning dozens of parallel trunk runs against a tight cutover window.
Designed for deployment in Panduit fiber infrastructure systems including OptiJack and OptiMOM high-density cassette and module platforms that accept MPO Female trunk interfaces. Connects to MPO-based patch panel systems, high-density cassette shelves, and modular fiber distribution frames from any vendor conforming to TIA-568.3-D MPO interface standards. The OS2 9/125µm singlemode fiber (ITU-T G.652.D) is compatible with 1G, 10G, 40G, 100G, and 400G single-mode transceivers — the fiber itself won't be the bottleneck as you migrate speeds. MPO Female connectors on both ends mate with standard MPO Male adapters; confirm your patch panel or cassette uses Male-polarity adapter sleeves before ordering. Standards compliance with TIA-568.3-D, ISO/IEC 11801, and ITU-T G.652.D ensures interoperability across multi-vendor network infrastructure deployments. LSZH jacket rating is required by code in plenum and enclosed-space installations across Europe and increasingly in US data center builds — verify your local code jurisdiction before substituting a non-LSZH alternative. OFNR (Optical Fiber Non-conductive Riser) rating supports vertical riser routing between floors without conduit in compliant building types.
At 864 fibers, this assembly is a large-diameter, high-mass cable — plan your cable management pathway and bend-radius compliance before pulling. OS2 singlemode requires tighter cleanliness discipline than multimode; end-face contamination is the leading cause of insertion-loss failures on MPO trunks at this fiber count. Inspect and clean all MPO connectors with an appropriate MPO-grade ferrule cleaner before mating. Minimum bend radius must be observed both during installation and at rest — consult the Panduit installation guide for this assembly's specific radius specification. The 50m length is fixed; confirm rack-to-rack or room-to-room distance including pathway routing (not straight-line) before ordering, as field-shortening a pre-terminated trunk is not an option.