Panduit F92RPU1U1ONM007 7m LC Uniboot OS2 Fiber Cord

Panduit F92RPU1U1ONM007 Opti-Core OS2 7m LC Duplex Uniboot Fiber Patch Cord The Panduit F92RPU1U1ONM007 is a 7-meter (23-foot) OS2 single-mode fiber o…

$74.18 $51.99 SAVE $22

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92RPU1U1ONM007 7m LC Uniboot OS2 Fiber Cord

$74.18
$51.99

Overview

SKU: F92RPU1U1ONM007
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92RPU1U1ONM007 Opti-Core OS2 7m LC Duplex Uniboot Fiber Patch Cord

The Panduit F92RPU1U1ONM007 is a 7-meter (23-foot) OS2 single-mode fiber optic patch cord engineered for high-density data center and telecom room deployments where space constraints and cable management matter. Built on Panduit's Opti-Core platform, this plenum-rated duplex patch cord uses LC uniboot connectors at both ends, cutting your cable pathway footprint in half compared to traditional dual-boot LC designs while delivering optimized insertion loss performance across 9µm single-mode fiber. The yellow jacket provides instant visual identification in mixed single-mode/multimode infrastructures, and the pull-boot connector design allows tool-free polarity reversal in the field—critical when you're cross-connecting pre-terminated cassettes in cramped rack environments or troubleshooting Tx/Rx mismatches without pulling the entire cable run.

Key Features

  • OS2 single-mode fiber (9µm core) rated for 10G/40G/100G Ethernet and long-haul applications up to 10 km or more depending on transceiver spec
  • LC Duplex Uniboot connectors both ends—single compact boot housing reduces cable congestion by 50% in high-density patch panels and switch ports
  • Pull-boot design enables tool-free polarity reversal in seconds without re-termination or adapter swaps
  • Plenum-rated OFNP jacket meets NEC Article 770 for air-handling spaces without conduit—UL 910 flame test compliant
  • Optimized insertion loss factory-tested to ensure margin on 10GBASE-LR, 40GBASE-LR4, and 100GBASE-LR4 links without exceeding channel loss budgets
  • Yellow jacket color (industry standard for single-mode OS2) prevents accidental cross-patching with OM3/OM4 multimode infrastructure
  • 7-meter (23-foot) length ideal for intra-rack connections, adjacent-rack cross-connects, or telecom room horizontal distribution to equipment racks

Single-mode OS2 fiber is the backbone of modern data center east-west traffic and storage-area-network fabrics where 10G SFP+ and 40G/100G QSFP28 optics dominate. The F92RPU1U1ONM007's 9-micron core and 125-micron cladding geometry supports chromatic dispersion specs that keep 10GBASE-LR and 10GBASE-ER links stable across campus distances, and the low attenuation (~0.4 dB/km at 1310 nm, ~0.3 dB/km at 1550 nm typical for OS2 fiber) preserves optical budget when you're chaining multiple patch points between SAN switches and storage arrays. Panduit's optimized insertion loss spec means each connector mating introduces minimal additional loss beyond the fiber's intrinsic attenuation—typically ≤0.25 dB per mated pair when factory-terminated, leaving you headroom against the IEEE 802.3ae 7.3 dB loss budget for 10GBASE-LR even after accounting for splice points and bulkhead adapters. The LC duplex uniboot form factor consolidates what would traditionally be two separate 1.6mm simplex cables into one 3.0mm pathway, cutting the cross-sectional area your cable managers and vertical organizers need to accommodate. In a 48-port 1RU switch fully populated with uniboot patch cords, you're managing 48 cables instead of 96—a difference that directly impacts airflow obstruction and technician access during MACs.

The uniboot pull-boot mechanism solves a persistent field problem: polarity mismatches during cassette-to-switch patching. In MTP/MPO-based structured cabling systems, the cassette pinout (Type A, Type B, Type C) dictates whether your duplex LC breakout has Tx and Rx on the correct fibers relative to the switch's transceiver pinout. If you discover a polarity error mid-install, traditional duplex LC patch cords require either a physical adapter swap (Type A-to-B adapter in the bulkhead) or complete cable replacement. Panduit's pull-boot design lets the technician grasp the boot tab, slide the boot back to expose the two LC connectors, pull them free from the internal housing, swap their left-right positions, and snap them back in—reversing polarity in under 30 seconds without tools or additional components. This is especially valuable in greenfield data center deployments where you're validating 200+ fiber links in a row; catching and fixing a polarity mistake on the spot keeps the commissioning schedule on track. The plenum OFNP jacket rating addresses NEC 770.113 requirements for cables installed in environmental air spaces (drop ceilings, raised floors, HVAC return plenums) without metal conduit or cable tray; the low-smoke, fire-retardant polymer formulation passes UL 910 Steiner Tunnel testing for flame spread and smoke generation, satisfying AHJ inspections in commercial office towers, hospitals, and edu/gov facilities where plenum compliance is non-negotiable.

The F92RPU1U1ONM007 ships as a single patch cord per package (carton quantity 10 for distributor case packs) and carries Panduit's manufacturer warranty covering defects in materials and workmanship. It meets or exceeds TIA-568-C.3 transmission performance for duplex single-mode fiber channels, TIA-604-3 (FOCIS-3) and TIA-604-10 (FOCIS-10) physical-contact connector geometry specs, and ISO/IEC 11801 international cabling standards. All components are RoHS-compliant per Directive 2002/95/EC, satisfying procurement requirements for EU and California-market installations. The 7-meter length hits the sweet spot for intra-row and short inter-row connections in modern data centers built on 42RU or 48RU racks with hot-aisle/cold-aisle layouts; it's long enough to route cleanly through overhead cable tray or underfloor pathways between adjacent rows without excessive service loop, but short enough to avoid the signal-degradation and handling issues that come with 15m+ patch cords coiled in the back of the rack. When you're building out a 10G or 40G spine-leaf fabric with Arista, Cisco Nexus, or Juniper QFX switches and need duplex single-mode connectivity that won't choke your cable management or force mid-deployment polarity corrections, this Opti-Core patch cord delivers the installation efficiency and performance margin commercial integrators expect from Panduit's structured cabling portfolio.

Specifications
Manufacturer: Panduit
MPN: F92RPU1U1ONM007
Product Type: Fiber Optic Patch Cord
Sub-Brand: Opti-Core®
Fiber Type: OS2 Single Mode
Fiber Core Diameter: 9 µm
Connector 1 Type: LC Duplex Uniboot
Connector 2 Type: LC Duplex Uniboot
Overall Length: 7 m (23 ft)
Cable Jacket Color: Yellow
Flammability Rating: Plenum (OFNP)
Number of Fibers: 2
Insertion Loss: Optimized (Factory Tested)
Standards Compliance: ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10)
RoHS Compliant: Yes (Directive 2002/95/EC)
Package Quantity: 1
Carton Quantity: 10
UPC: 61305681083
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources