Panduit F92ELB1LNSNM006 6m OS2 LC Duplex Patch Cord

Panduit F92ELB1LNSNM006 Opti-Core OS2 Single-Mode Fiber Patch Cord The Panduit F92ELB1LNSNM006 is a 6-meter OS2 single-mode fiber optic patch cord eng…

$69.76 $45.99 SAVE $24

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92ELB1LNSNM006 6m OS2 LC Duplex Patch Cord

$69.76
$45.99

Overview

SKU: F92ELB1LNSNM006
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92ELB1LNSNM006 Opti-Core OS2 Single-Mode Fiber Patch Cord

The Panduit F92ELB1LNSNM006 is a 6-meter OS2 single-mode fiber optic patch cord engineered for high-performance datacenter, enterprise backbone, and long-haul telecom applications where insertion loss, return loss, and signal integrity are non-negotiable. Built on Panduit's Opti-Core platform, this duplex jumper features LC connectors on both ends — standard UPC (Ultra Physical Contact) polish on one side and APC (Angled Physical Contact) on the other — enabling seamless integration into DWDM, CWDM, passive optical LAN, and high-speed storage networks that demand sub-0.35 dB insertion loss and better than -60 dB return loss. The yellow LSZH (Low Smoke Zero Halogen) jacket meets IEC 60332-1 and 60754 flammability and toxicity standards, making it code-compliant for indoor riser, plenum-equivalent, and confined-space installations across North America, EU, and APAC markets. At 19.68 feet, this cable bridges typical rack-to-rack distances in structured cabling environments, SAN fabrics, and fiber-to-the-desk deployments without requiring mid-span splicing or excessive service loops that increase failure points.

Key Features

  • OS2 Single-Mode Fiber (9/125 μm): ITU-T G.652.D compliant core supports 10G/40G/100G Ethernet, 16G/32G Fibre Channel, and DWDM transmission over distances exceeding 10 km with chromatic dispersion ≤18 ps/nm·km at 1550 nm
  • Hybrid UPC/APC Connector Configuration: LC Duplex UPC on one end, LC Duplex APC on the other — ideal for connecting standard enterprise switches to APC-equipped GPON OLTs, CATV headends, or analog RF-over-fiber systems where back-reflection must stay below -65 dB
  • Factory-Terminated & Tested: Each duplex assembly ships with insertion loss ≤0.35 dB and return loss ≥50 dB (UPC) / ≥60 dB (APC) per IEC 61300-3-4 and IEC 61300-3-35, verified via automated interferometric inspection — eliminates field termination labor and variability
  • LSZH Jacket (IEC 60332-1 & 60754): Halogen-free, low-smoke compound limits toxic gas emission and optical obscuration during fire events — required for EU CPR Euroclass ratings, NFPA 90A air-handling spaces, and transit/tunnel projects under NFPA 130
  • Yellow Outer Jacket: TIA-598-C color code for OS2 single-mode fiber — prevents accidental cross-connection with OM3/OM4 multimode circuits during MACs (moves, adds, changes) in converged multi-tier networks
  • Pull-Proof Boot Design: Strain-relief boots molded to 900 μm tight-buffered fiber maintain minimum bend radius (15 mm dynamic, 10 mm static per IEC 60794-2) and protect ferrule endface from impact damage during installation and service
  • 6-Meter Length (19.68 ft): Pre-cut to fit standard 42U open-frame racks spaced 6–8 feet apart, reducing cable waste and service-loop clutter in hot/cold aisle containment systems, overhead cable trays, and under-floor pathways
  • Opti-Core Quality Assurance: Manufactured under ISO 9001:2015 and TL 9000 telecom quality management systems with lot-traceability, ensuring consistent performance across multi-building campus deployments and spares inventory management

Technical Performance & Insertion Loss Budget: OS2 single-mode fiber in the F92ELB1LNSNM006 supports wavelengths from 1260 nm to 1625 nm (O-band through L-band), making it compatible with legacy 1310 nm Fast Ethernet, contemporary 1310/1550 nm BiDi SFP+ transceivers, and future 1577 nm coherent pluggables. The 9 μm core diameter and ≤0.4 dB/km attenuation at 1310 nm allow this 6-meter jumper to contribute just 0.002 dB of fiber attenuation to your link budget — negligible compared to connector pair loss (0.35 dB max per IEC 61300-3-4). The APC endface, polished at an 8-degree angle, reflects light back into the cladding rather than the core, suppressing cavity resonance and modal noise that degrades BER in analog CATV distribution, coherent DWDM, and high-order modulation formats like PAM4. UPC endfaces on the opposite connector deliver <-50 dB return loss, sufficient for standard 10GBASE-LR and 40GBASE-LR4 links while maintaining interoperability with installed base equipment lacking APC ports. When deploying in duplex LC infrastructure, observe polarity method B (TIA-568-C.0 Annex A) or use key-up/key-down orientation marking to avoid Tx-Rx swaps that prevent link establishment — Panduit's blue pull-tab on the duplex clip denotes Fiber A, simplifying field verification during acceptance testing.

Installation Context & Code Compliance: LSZH jacketing on this patch cord satisfies NEC Article 770 for optical fiber cables installed in air-handling spaces (plenum, riser) where PVC combustion byproducts — hydrochloric acid and dense smoke — pose life-safety hazards and equipment corrosion risks. IEC 60754-1 halogen acid gas content測定 confirms <0.5% HCl emission, and IEC 61034 smoke density measurement yields light transmittance >60%, meeting Euroclass B2ca-s1a,d1,a1 under EN 50575 CPR (Construction Products Regulation) for permanent indoor installation across EU member states. For US datacenter projects pursuing LEED, WELL, or ASHRAE 90.1 compliance, LSZH cables reduce Scope 3 environmental impact and improve post-fire recovery timelines by minimizing particulate contamination of white-space HVAC systems and raised-floor plenums. The 6-meter length aligns with TIA-568.3-D horizontal fiber link budgets, where up to 15 meters of total patch cord (5 m work area + 5 m consolidation point + 5 m telecom room) is permitted before exceeding the 2.0 dB channel insertion loss limit for 10GBASE-SR or 1.9 dB for 40GBASE-SR4 over OM4. In storage area networks running 32G FC or NVMe-oF, this jumper's <0.35 dB insertion loss and >50 dB return loss ensure compliance with Fibre Channel Physical Interface (FC-PI-6) optical specifications, preventing CRC errors and frame retransmissions that throttle IOPS in all-flash arrays. Always clean LC ferrule endfaces with IPA (isopropyl alcohol) wipes and inspect under 200× fiber microscope before mating — a single 5 μm dust particle can increase insertion loss by 0.8 dB and trigger OSNR (optical signal-to-noise ratio) alarms in metro DWDM rings.

This patch cord is built for integrators running structured cabling projects under TIA-568.3-D or ISO/IEC 11801-1 standards, where factory-terminated assemblies reduce labor costs, eliminate fusion-splice truck rolls, and deliver warrantable performance out of the box. The Opti-Core line ships with test reports traceable to NIST-referenced insertion loss and return loss standards, streamlining third-party acceptance testing and owner turnover documentation. Panduit's yellow jacket coding integrates into existing single-mode infrastructures without requiring new labeling schemes, and the hybrid UPC/APC configuration future-proofs against equipment upgrades where APC is becoming mandatory — GPON ONTs, DOCSIS 3.1 node optics, and passive optical LAN splitters all demand APC to avoid reflection-induced CNR (carrier-to-noise ratio) degradation in analog video overlays.

Specifications
Manufacturer: Panduit
MPN: F92ELB1LNSNM006
Product Line: Opti-Core
Product Type: Fiber Optic Patch Cord
Fiber Type: OS2 Single-Mode (9/125 μm)
Connector 1: LC Duplex UPC
Connector 2: LC Duplex APC
Number of Fibers: 2 (Duplex)
Cable Length: 6 m (19.68 ft)
Cable Jacket Color: Yellow
Jacket Material: LSZH (Low Smoke Zero Halogen)
Insertion Loss (Max: ≤0.35 dB per IEC 61300-3-4
Return Loss (Min: ≥50 dB UPC / ≥60 dB APC
Flammability Rating: IEC 60332-1, IEC 60754
Operating Temperature: -20°C to +70°C
Wavelength Range: 1260–1625 nm
Standards Compliance: TIA-568.3-D, ISO/IEC 11801-1, ITU-T G.652.D
Package Quantity: 1
Carton Quantity: 10
UPC: 061305680528
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources