Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FW2ERQ1Q1NNF036
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 1% OFF

Panduit FW2ERQ1Q1NNF036 36 ft Duplex LC OM4 Fiber Cable

Panduit FW2ERQ1Q1NNF036 Duplex LC Fiber Patch Cable The Panduit FW2ERQ1Q1NNF036 is a 36-foot duplex multimode fiber optic patch cable engineered for h…

$110.78 $109.99 SAVE $1

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FW2ERQ1Q1NNF036 36 ft Duplex LC OM4 Fiber Cable

$110.78
$109.99

Overview

SKU: FW2ERQ1Q1NNF036
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FW2ERQ1Q1NNF036 Duplex LC Fiber Patch Cable

The Panduit FW2ERQ1Q1NNF036 is a 36-foot duplex multimode fiber optic patch cable engineered for high-density data center interconnects, SAN backbone extensions, and commercial AV-over-IP deployments where reliable 10/40/100GbE transmission is non-negotiable. Built on 50/125 µm OM4 fiber with aqua jacket, it delivers 400 MHz·km modal bandwidth at 850 nm—sufficient for 100GBASE-SR4 runs up to 100 meters or 10GBASE-SR links to 400 meters. LC duplex connectors on both ends provide push-pull latching for tool-free insertion into SFP+/QSFP28 transceiver cages, patch panels, and media converters across Axis, Hanwha, Bosch, and Genetec IP video infrastructures. The 3.0 mm round cordage simplifies cable management in congested racks and reduces pathway fill compared to zipcord designs, while TIA-568.3-D compliance and IEC 61754-20 insertion-loss specs (≤0.30 dB typical) ensure interoperability with enterprise-grade optics from Cisco, Aruba, Juniper, and Ubiquiti UniFi switching platforms.

Key Features

  • 50/125 µm OM4 multimode fiber with 400 MHz·km modal bandwidth at 850 nm for 100G SR4 and 40G SR4 applications
  • LC duplex connectors—push-pull design fits SFP+, SFP28, and QSFP28 transceivers without adapter plates
  • 36-foot cable length bridges in-row distribution to end-of-row aggregation switches or cross-connects adjacent equipment racks
  • 3.0 mm round jacket—50% smaller cross-section than zipcord reduces conduit fill and improves airflow in high-density server aisles
  • Aqua jacket per TIA-598-D color code instantly identifies OM4 grade during moves, adds, and changes
  • Insertion loss ≤0.30 dB and return loss ≥20 dB per IEC 61754-20 ensure link budget margin for 10GBASE-SR at 400 m

Every FW2ERQ1Q1NNF036 assembly ships factory-terminated and 100% optically tested, eliminating field fusion-splicing labor and the risk of contamination-induced packet loss. The LC connector ferrules use ceramic alignment sleeves and are pre-polished to <50 nm surface finish—critical for maintaining return loss above 20 dB when mated to Panduit FAP or FMP cassettes, Corning Edge breakout panels, or OEM transceiver ports. The OM4 fiber core supports laser-optimized 850 nm VCSEL sources in 10GBASE-SR, 40GBASE-SR4, and 100GBASE-SR4 optics, delivering 4.5 dB worst-case link loss allocation per IEEE 802.3-2018 Table 86-11. This headroom accommodates up to eight mated connector pairs (16 dB) plus splice losses in tiered campus or storage-area-network topologies. The round 3.0 mm jacket uses riser-rated (OFNR) PVC compound suitable for plenum-substitution under NEC 770.113(A) exception, though integrators running cable through return-air plenums must specify the OFNP-rated variant. Bend radius remains 10× cable diameter (30 mm) under no-load conditions and 20× during installation, preventing macrobend attenuation spikes that degrade margin on temperature-sensitive 25G and 100G links.

In video-surveillance control rooms, this cable typically connects core switches with 10G SFP+ uplink ports to aggregation-layer devices in adjacent racks—Genetec Archiver servers with dual-port fiber NICs, Milestone Husky NVRs, or Bosch DIVAR IP 7000 recorders demanding sustained 8 Gbps write bandwidth across RAID arrays. The 36-foot length suits row-to-row or back-to-back rack installations without excess service loop, reducing clutter in overhead cable trays and simplifying fault isolation when a link drops mid-shift. Duplex LC termination matches the de facto standard for enterprise networking; integrators stock a single connector type rather than juggling SC, ST, and MPO inventories. The aqua jacket provides instant visual confirmation of OM4 grade during audits—critical when inherited campus fiber infrastructure mixes OM3 (300 MHz·km) and OM4 (400 MHz·km) runs that look identical under white LED inspection light. Pair this assembly with Panduit FQEPP-C LC-to-LC bulkhead adapters or Corning CCH-CP48-A9-A9 single-mode cassettes for break-out applications, ensuring ferrule endface geometry remains within the 50 nm surface-finish spec after repeated connect/disconnect cycles during troubleshooting.

Panduit's manufacturing process includes endface inspection per IEC 61300-3-35, eliminating the scratches, pits, and lippage that cause back-reflection and intersymbol interference on 25 Gbps-per-lane PAM4 signaling. Each connector is serialized for traceability, and the cable jacket is printed with part number, length, and test-date code—streamlining warranty claims and change-order verification when clients question whether the installed grade meets 100GBASE-SR4 reach requirements. Mount this cable in horizontal or vertical orientations; the round cordage resists kinking when dressed through Panduit PanZone zero-U vertical managers or Chatsworth SlimFrame cable rings. For integrators deploying Axis Camera Station Pro with 4K H.265 streams, Hanwha Wisenet WAVE with multi-sensor 32 MP cameras, or Bosch Video Management System clusters writing to Qumulo or Pure Storage FlashBlade arrays, the FW2ERQ1Q1NNF036 provides the low-latency, low-loss fiber backbone that keeps pixel-perfect evidence accessible during forensic review—no dropped frames, no CRC errors, just deterministic 10 Gbps throughput validated by BERT testing at the factory.

Specifications
Product Type: Fiber Optic Patch Cable
Connector Type A: LC Duplex
Connector Type B: LC Duplex
Fiber Type: Multimode OM4
Core/Cladding Diameter: 50/125 µm
Modal Bandwidth: 400 MHz·km at 850 nm
Cable Length: 36 feet
Jacket Type: Riser (OFNR)
Jacket Color: Aqua
Cable Diameter: 3.0 mm
Insertion Loss: ≤0.30 dB (typical)
Return Loss: ≥20 dB
Bend Radius (No-Load: 30 mm (10× diameter)
Bend Radius (Installation: 60 mm (20× diameter)
Compliance: TIA-568.3-D, IEC 61754-20, TIA-598-D
Application: 10GBASE-SR, 40GBASE-SR4, 100GBASE-SR4
Temperature Range: -20°C to +70°C
Polarity: Type A (straight-through)
Connector Polish: Physical contact,
Type: Fiber Optic Patch Cable
Connectivity: LC Duplex
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources