Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FWTYL7575LNM034
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 41% OFF

Panduit FWTYL7575LNM034 OM5 12-Fiber PanMPO Trunk - 34m

Panduit FWTYL7575LNM034 QuickNet OM5 12-Fiber PanMPO Trunk Cable Assembly The Panduit FWTYL7575LNM034 is a 34-meter OM5 trunk cable assembly engineere…

$2,057.04 $1,209.99 SAVE $847

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FWTYL7575LNM034 OM5 12-Fiber PanMPO Trunk - 34m

$2,057.04
$1,209.99

Overview

SKU: FWTYL7575LNM034
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FWTYL7575LNM034 QuickNet OM5 12-Fiber PanMPO Trunk Cable Assembly

The Panduit FWTYL7575LNM034 is a 34-meter OM5 trunk cable assembly engineered for high-density data center deployments requiring extended reach and rapid infrastructure provisioning. This 12-fiber trunk uses PanMPO female-to-female connectors with Method B polarity, HD Flex small-diameter construction, and LSZH jacketing to address pathway congestion, fire-safety mandates, and short-wavelength division multiplexing (SWDM) requirements in 40G/100G/400G networks. The QuickNet factory-terminated design eliminates field splicing and delivers ultra-low insertion loss performance verified to TIA-568-C.3 and ISO/IEC 11801 standards, cutting deployment time from hours to minutes while maintaining the precision required for loss-budget-sensitive 400GBASE-SR8 and emerging 800G applications.

Key Features

  • OM5 wideband multimode fiber — 50 µm core supports traditional 850 nm SR optics plus 850/880/910/940 nm SWDM, extending reach to 400 m for 100GBASE-SR4 and enabling cost-effective migration to 400G without infrastructure replacement
  • PanMPO female-to-female connectivity — 12-fiber MT ferrule interface provides push-pull latch retention, 0.25 dB typical insertion loss per connector, and compatibility with 40G/100G QSFP transceivers and breakout modules
  • Method B polarity — Key-up to key-down orientation reverses fiber positions at opposite ends, enabling straight-through trunk deployment for duplex transceiver pairs without crossover adapters or on-site re-pinning
  • HD Flex cable construction — 3.0 mm trunk diameter consumes 30–40% less pathway volume than legacy 12-fiber designs, critical for ASHRAE-compliant hot-aisle containment installations and congested overhead cable trays
  • LSZH flame rating — Low smoke zero halogen jacket meets IEC 60332-1 and 60754 requirements for plenum-equivalent safety in occupied spaces and international installations where PVC combustion byproducts are prohibited
  • Ultra insertion loss grade — Factory testing to 0.15 dB maximum per mated connector pair (versus 0.35 dB industry standard) preserves link budget on 100 m+ runs, essential for 400GBASE-SR8 1.9 dB total-channel budget compliance
  • 34-meter engineered length — Precisely matches row-to-aggregation distances in modular data centers and meets structured cabling permanent-link requirements without service loops or excess slack management
  • QuickNet factory termination — Pre-polished MT ferrules, continuity-tested fiber pairs, and individually serialized test reports eliminate field epoxy/polish labor and deliver same-day turn-up for emergency capacity additions

OM5 fiber represents the current multimode standard for data centers committed to 25G-per-lane optics and beyond. Unlike OM3/OM4 that optimize solely for 850 nm VCSEL transmission, OM5 adds effective modal bandwidth (EMBc) specifications at 880, 910, and 940 nm wavelengths, enabling four-channel SWDM over a single duplex fiber pair. This matters when migrating from 100GBASE-SR4 (four 25G lanes over eight fibers) to 100G-SWDM4 (four wavelengths over two fibers), cutting required fiber count by 75 percent and freeing MPO trunk positions for future growth. The FWTYL7575LNM034's 50 µm graded-index core delivers 3,500 MHz·km minimum bandwidth at 850 nm and 1,850 MHz·km at 953 nm per TIA-492-AAAD, supporting 100GBASE-SR4 to 150 meters and 400GBASE-SR8 to 100 meters with margin for connector and splice losses. The HD Flex cable uses bend-insensitive fiber meeting IEC 60793-2-10 A1a.3 specifications, tolerating 7.5 mm bend radius under load — necessary when routing trunks through vertical cable managers, around patch-panel edges, and into breakout harnesses without macrobend attenuation. PanMPO connectors use Panduit's metal-shell push-pull housing with integrated strain relief and visual key-up/key-down indication, preventing mis-mating during MAC work. The MT ferrule is factory-polished to sub-50 nm surface finish and inspected per IEC 61300-3-35 for scratches and contamination, eliminating the end-face defects that cause 0.5+ dB insertion-loss failures on field-terminated assemblies. Each connector includes a removable dust cap and ships with an individual IL/RL test report showing per-fiber insertion loss (typical 0.12 dB) and return loss (≥−40 dB), traceable to NIST-calibrated reference standards.

Data center deployments favor pre-terminated trunks over pull-and-terminate field cabling for three reasons: speed, repeatability, and loss performance. A single technician can install six FWTYL7575LNM034 trunks — 72 fiber connections — in the time required to fusion-splice and test one 12-fiber breakout assembly. This speed matters during compute-refresh cutovers, SAN expansions, and after-hours maintenance windows where rack access is measured in minutes, not hours. The 34-meter length suits aggregation-layer interconnects in modular data centers using 12-meter row depths: 10 m riser + 12 m horizontal + 10 m vertical distribution + 2 m service loop lands precisely within the 34 m engineered length without wasteful coiling or inadequate reach. Method B polarity (also called straight-through with crossover) inverts fiber positions so position 1 at the transmit end connects to position 12 at the receive end, matching the pinout of duplex LC transceivers when used with Method B breakout cassettes. This eliminates the Type-A to Type-B adapter juggling that causes 50 percent of day-two fiber troubleshooting calls. LSZH jacketing is mandatory in EMEA, APAC, and increasingly in U.S. Navy and DoD facilities where PVC's hydrochloric acid smoke byproduct poses corrosion risk to electronics and life safety to occupants. The lime jacket color conforms to TIA-598-D OM5 coding, preventing accidental cross-connection with OM3 aqua or OM4 erika violet trunks during adds/moves/changes. HD Flex's reduced diameter directly impacts pathway fill: a 4-inch horizontal ladder rack with 50 percent fill derating supports 180 HD Flex trunks versus 110 legacy 12-fiber trunks, deferring costly runway additions. When deploying this trunk between 40GBASE-SR4 or 100GBASE-SR4 switches, pair it with Panduit's FMT-Series Method-B 12-fiber-to-6-duplex-LC breakout cassettes at each end, maintaining polarity without crossover adapters and providing individual LC ports for test access. For 400GBASE-SR8 (which requires two 12-fiber MPO connectors per port), use back-to-back trunks or transition to 24-fiber MPO assemblies at the switch fabric.

The FWTYL7575LNM034 ships with factory test data showing per-fiber insertion loss, return loss, length, and polarity verification, meeting TIA-568-C.0 Tier 2 certification requirements without on-site OTDR testing. It complies with RoHS 3 (2015/863/EU) lead and heavy-metal restrictions, ISO/IEC 11801-1 Class FA structured cabling, and TIA-568-C.1 recognized multimode backbone specifications. This specific assembly is engineered for leaf-spine fabrics requiring OM5 future-proofing, installations where LSZH is mandated by local fire code, and scenarios where 30+ meter reach exceeds OM4's 400G distance but doesn't justify singlemode conversion. Pair with Panduit's FQCLC quad LC modules or Opticom breakout panels for structured patching, and specify matching lime OM5 jumpers for end-device connections to maintain visual infrastructure consistency across the physical layer.

Specifications
Manufacturer: Panduit
MPN: FWTYL7575LNM034
Product Type: Trunk Cable Assembly
Sub-Brand: QuickNet
Fiber Type: OM5 Wideband Multimode
Number of Fibers: 12
Fiber Diameter: 50 µm
Connector Type A: PanMPO Female
Connector Type B: PanMPO Female
Polarity Method: Method B
Cable Construction: HD Flex Transition
Overall Length: 34 m (111.55 ft)
Cable Jacket Color: Lime
Flammability Rating: LSZH (Low Smoke Zero Halogen)
Insertion Loss Grade: Ultra
Standards Compliance: TIA-568-C.3, ISO/IEC 11801, TIA-492-AAAD, IEC 60793-2-10 A1a.3, TIA-604-5 (FOCIS-5), RoHS
Application: Data center aggregation, 40G/100G/400G networks, high-density structured cabling
Package Quantity: 1
UPC: 61305636030
Type: Trunk Cable Assembly
Connectivity: PanMPO
Sub Brand: QuickNet™
Fiber Count: 12
Length Ft: 111.55
Length M: 34
Carton Qty: 0
Package Qty: 1
Standards: Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-5), TIA/EIA-568-C.1, RoHS compliant,TIA-492-AAAD, IED 60793-2-10 type A1a.3
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources