Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit FWTYL7575LAM044 QuickNet 12-fiber OM5 trunk cable assembly delivers 44 meters of pre-terminated wideband multimode fiber in a small-diameter LSZH jacket, purpose-built for high-density datacenter and enterprise backbone installations. OM5 fiber supports shortwave division multiplexing (SWDM) for 100GBASE-SR4, 200G, and 400G Ethernet over extended multimode reach, enabling spine-leaf architectures and inter-row links without the cost step to singlemode. The lime jacket provides rapid visual identification in mixed-fiber environments, while the reduced-diameter trunk design saves 30 to 40 percent pathway space compared to traditional 12-fiber assemblies—critical in congested overhead ladder rack and underfloor conduit runs where every cubic inch counts.
OM5 wideband multimode fiber extends the usable spectrum of traditional OM4 from 850nm to a four-wavelength window (850nm, 880nm, 910nm, 940nm), enabling shortwave division multiplexing (SWDM) transceivers to deliver 100GBASE-SR4, 200GBASE-SR4, and 400GBASE-SR4.8 over 150 meters on 12 fibers instead of requiring 24 or 48 fibers with parallel optics. This quadruples effective bandwidth density within a fixed fiber count, making OM5 the most cost-efficient multimode upgrade path for datacenters running 40G today and planning 100G-plus spine links tomorrow. The 44-meter length is precisely sized for inter-row spine-to-leaf links in mid-scale datacenters (typical row spacing of 30-40m), zone-to-zone horizontal distribution in enterprise campuses, and main distribution area (MDA) to horizontal distribution area (HDA) riser runs in multi-floor facilities. Panduit's manufacturing process ensures each fiber meets the TIA-492-AAAD and IEC 60793-2-10 Type A1a.3 specifications for modal bandwidth—minimum 4700 MHz·km at 850nm—enabling link budgets that support 100 meters at 100GBASE-SR4 or 150 meters at 40GBASE-SR4 with standards-compliant SR4 optics and low-loss patch cords. Factory polishing to TIA-604-5 (FOCIS-5) endface geometry guarantees maximum insertion loss under 0.35dB per mated connector pair and return loss better than -20dB, eliminating the field variability, rework cycles, and failed OTDR tests that plague site-terminated fiber installations.
QuickNet pre-terminated trunk assemblies collapse installation timelines by arriving on-site with connectors already factory-installed, insertion-loss tested, and serialized with test reports. For a 12-fiber trunk, this eliminates roughly six hours of field labor—fusion splicing twelve fibers, installing furcation kits, polishing or mechanical-splice terminations, and running per-connector insertion loss and return loss tests—compared to pulling loose-tube cable and terminating on-site. On prevailing-wage commercial jobs, that labor savings typically pays for the trunk premium on any deployment larger than a single rack. The small-diameter construction is purpose-built for congested pathways: traditional 12-fiber distribution cables range from 0.45" to 0.55" outer diameter, while Panduit's reduced-diameter trunks measure closer to 0.30" OD, yielding a 30 to 40 percent reduction in cross-sectional area and a corresponding reduction in pathway fill. In a 4" × 4" ladder rack section with a 40% NEC fill ratio limit, this diameter difference translates to fitting 18 trunks instead of 12 in the same pathway—enough headroom to add three more spine switch uplinks or a full leaf-switch row without recabling the overhead distribution. The LSZH (Low Smoke Zero Halogen) jacket formulation is non-negotiable for indoor datacenter and vertical riser applications: NEC Article 770.179 and International Building Code Chapter 8 both mandate low-smoke, low-toxicity cables in plenum air-handling spaces and vertical riser shafts, and LSZH compounds produce less than 0.5% hydrogen chloride and less than 5% light-obscuration smoke under UL 910 combustion testing, compared to 20-30% HCl and 40%+ obscuration for PVC-jacketed cables. In enclosed equipment rooms and riser shafts, this difference is life-safety critical—corrosive acid gases destroy sensitive electronics, corrode copper busbars, and create respiratory hazards for personnel, while dense smoke obscures egress paths and emergency lighting.
The lime green jacket color follows TIA-568.3-D Annex F color-coding guidance for OM5 fiber, enabling installers and operations teams to visually distinguish OM5 trunks from aqua OM3 (TIA Annex A) and erika violet OM4 (TIA Annex E) runs at a glance during adds, moves, and changes. This color segregation is critical in mixed-generation datacenter plants where mismatching a 100GBASE-SR4 SWDM transceiver (designed for OM5) to an OM3 link will cut the supported distance from 100m to 70m, potentially causing intermittent link flaps or complete failure on longer inter-row runs. Visual identification reduces these misconfigurations during after-hours maintenance windows when techs are working fast under pressure. The 12-fiber count is the industry-standard trunk size for spine-to-leaf datacenter fabrics (one 12-fiber trunk per switch uplink, supporting six duplex LC ports or one 12-fiber MTP/MPO breakout), enterprise floor-to-floor risers (backbone capacity for six duplex endpoints per floor), and campus zone distribution (star topology from central MDA to six building entrance facilities). Panduit's QuickNet platform uses push-pull or key-up/key-down MTP/MPO-style connectors with alignment pins on one end and no pins on the other (Method B polarity), ensuring correct transmit-to-receive mapping when mating to standards-compliant cassettes or direct-attach trunk ports.
This assembly meets or exceeds TIA/EIA-568-C.1 (commercial building telecom cabling), TIA/EIA-568-C.3 (optical fiber cabling components), TIA-604-5 (FOCIS-5 fiber optic connector intermateability standard), ISO/IEC 11801 Edition 2.2 (generic cabling for customer premises), TIA-492-AAAD (OM5 fiber performance specification), and IEC 60793-2-10 Type A1a.3 (multimode graded-index fiber detail specification) standards, ensuring interoperability with any standards-compliant transceiver, patch panel, cassette, or direct-attach equipment in your infrastructure. RoHS compliance satisfies EU Directive 2011/65/EU for restricted substances (lead, mercury, cadmium, hexavalent chromium, PBB, PBDE), a mandatory requirement for multinational datacenter operators and European enterprise sites subject to WEEE enforcement. For integrators designing 100G-ready spine-leaf fabrics, campus fiber backbones, or enterprise multi-floor risers that must support 40G today and scale to 200G or 400G within the next three to five years without a forklift fiber replacement, the FWTYL7575LAM044 delivers the modal bandwidth, physical reach, installation speed, and pathway density to meet aggressive deployment schedules while maintaining performance headroom for the next two transceiver generations.