Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FZ2RPU1U1ONM8.5 Multimode Fiber Patch Cable

The Panduit FZ2RPU1U1ONM8.5 is a factory-terminated 2-fiber duplex multimode patch cable delivering 8.5 meters of pre-tested connectivity for datacenter, enterprise network, and AV-over-IP installations. Built with OM3 or OM4 50/125 micron multimode fiber and LC uniboot connectors on both ends, this cable assembly eliminates field termination risk while providing the bend-radius protection and insertion-loss performance critical to 10G/40G Ethernet and Fibre Channel SAN links. Panduit's controlled-environment manufacturing ensures <0.3 dB typical insertion loss and >-50 dB return loss across the duplex pair — specifications that field terminations rarely match without specialized test gear.

Key Features

  • 8.5-meter (27.9 ft) pre-terminated duplex assembly — ideal for cross-rack or intra-row datacenter runs
  • LC uniboot connectors — push-pull latch design with integrated boot for simplified cable management and polarity reversal
  • OM3/OM4 multimode fiber — supports 10GBASE-SR up to 300 m, 40GBASE-SR4 up to 150 m, and 100GBASE-SR10 applications
  • Factory-tested insertion loss and return loss — certificates available via Panduit's serialized QA system
  • Riser-rated (OFNR) or plenum-rated (OFNP) jacket options — meets NEC Article 770 for vertical and horizontal pathway installation
  • Aqua or other OM3/OM4-compliant jacket color for TIA-598-D visual identification

This cable assembly addresses the install challenge every datacenter tech knows: reliable multimode performance in constrained spaces. The 8.5 m length fits typical rack-to-rack or top-of-rack switch deployments without the 3-meter slack coil or 15-meter excess that complicates pathway fill and airflow. LC uniboot connectors reduce port density by half compared to traditional duplex LC — a 48-port switch panel consumes the footprint of a 24-port duplex layout, letting you defer costly switch upgrades when port count climbs. The push-pull latch survives 500+ mating cycles per TIA-604-10-D without the hairline cracks that plague cheaper brands after a dozen reconfigurations, and the integrated strain relief maintains the 30 mm minimum bend radius even when cables are dressed tightly against patch-panel edges.

Panduit's factory-terminated process uses automated cleave-and-polish with real-time interferometry — every connector end-face is inspected for scratches, contamination, and geometry per IEC 61300-3-35 before the cable leaves the production line. That's why insertion loss holds to ≤0.35 dB typical (≤0.5 dB max) across the link, and return loss exceeds -50 dB — performance margins that keep bit-error rates below 10^-12 even on 100-meter OM4 links at 25 Gb/s per lane. Field terminations, even with good epoxy-polish technique, rarely break -40 dB return loss, and the 0.1 dB difference compounds across a 6-hop storage fabric into measurable packet loss during sustained IOPS bursts.

Install this cable in TIA-568-compliant structured cabling systems as a equipment-cord link between active gear and permanent fiber backbone infrastructure. The LC uniboot format integrates directly with Panduit's FAP cassette modules, FMT modular panels, and OptiCam pretium systems — no adapter flanges or hybrid patch panels required. Pair with Panduit's FOCSCSTK fiber cleaning sticks and FiberWipe tissues to maintain end-face cleanliness between reconfigurations; every unmount/remount cycle deposits airborne particulate that degrades return loss by 2-5 dB if left unaddressed. For polarity-sensitive 40G/100G SR4/SR10 applications, the uniboot's field-reversible key lets you flip A/B polarity at either end without re-terminating — a five-second fix for the mismatched Tx/Rx polarity that otherwise means a truck roll or a spare cable pull.

Specifications
Product Type: Fiber Optic Patch Cable
Manufacturer: Panduit
MPN: FZ2RPU1U1ONM8.5
Cable Length: 8.5 meters (27.9 ft)
Fiber Type: Multimode OM3/OM4 50/125 μm
Fiber Count: 2-fiber duplex
Connector Type A: LC Uniboot
Connector Type B: LC Uniboot
Polarity: Type A or Type B (field-reversible uniboot key)
Insertion Loss (Typical: ≤0.35 dB
Insertion Loss (Max: ≤0.5 dB
Return Loss: >-50 dB
Jacket Rating: OFNR (Riser) or OFNP (Plenum)
Jacket Color: Aqua (OM3/OM4 standard per TIA-598-D)
Minimum Bend Radius: 30 mm (loaded), 50 mm (unloaded)
Operating Temperature: -20°C to +70°C
Standards Compliance: TIA-568, TIA-604-10-D, IEC 61300-3-35, NEC Article 770
Applications: 10GBASE-SR, 40GBASE-SR4, 100GBASE-SR10, Fibre Channel 16G/32G
Mating Durability: 500+ cycles per TIA-604-10-D
Factory Testing: Insertion loss and return loss certified per cable serial number
Type: Fiber Patch Cable
Connectivity: LC Uniboot
Form Factor: Duplex 2-Fiber
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

Panduit FZ2RPU1U1ONM8.5 8.5m Duplex Fiber Patch Cable

$89.90
$88.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources