Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FZ2RPU1U1NNM020
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 35% OFF

Panduit FZ2RPU1U1NNM020 OM4 LC Uniboot Patch Cord 20m

Panduit FZ2RPU1U1NNM020 Opti-Core OM4 LC Duplex Uniboot Fiber Patch Cord - 20m Plenum The Panduit FZ2RPU1U1NNM020 Opti-Core fiber patch cord delivers …

$135.20 $87.99 SAVE $47

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FZ2RPU1U1NNM020 OM4 LC Uniboot Patch Cord 20m

$135.20
$87.99

Overview

SKU: FZ2RPU1U1NNM020
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FZ2RPU1U1NNM020 Opti-Core OM4 LC Duplex Uniboot Fiber Patch Cord - 20m Plenum

The Panduit FZ2RPU1U1NNM020 Opti-Core fiber patch cord delivers 40/100G-ready OM4 multimode connectivity for modern data centers and high-density telecom installations where low insertion loss and physical space constraints drive design decisions. Built on 50/125μm OM4 fiber with aqua jacket and duplex LC uniboot terminators at both ends, this 20-meter plenum-rated cable supports 10GBASE-SR to 100GBASE-SR4 applications while consuming half the panel real estate of traditional duplex LC patch cords. The pull-boot uniboot design simplifies polarity management during moves/adds/changes and reduces the risk of fiber damage during installation in congested pathways—critical when you're working behind occupied equipment racks or in live production environments where a single damaged ferrule can take down a critical storage or server link.

Key Features

  • OM4 50/125μm laser-optimized multimode fiber supports 10GBASE-SR (400m), 40GBASE-SR4 (150m), and 100GBASE-SR4 (150m) over parallel optics
  • LC duplex uniboot connectors at both ends—one housing per duplex pair reduces panel congestion by 50% vs. traditional dual-LC simplex boots
  • Pull-boot uniboot design allows tool-free single-hand polarity reversal and provides strain relief during installation and removal
  • Ultra-low insertion loss specification (typically <0.25 dB) ensures headroom for multi-connector channels and extended reach applications
  • Plenum (OFNP) rated jacket complies with NEC Article 770.113 for installation in air-handling spaces without conduit
  • Aqua cable jacket color per TIA-598-D fiber identification standard for immediate OM4 recognition in mixed-fiber environments
  • 20-meter (65.6 ft) length suits horizontal cross-connects, rack-to-rack interconnects, and zone distribution area cabling in structured cabling deployments
  • Factory-terminated and tested for insertion loss, return loss, and connector geometry—eliminates field termination labor and variability
  • RoHS compliant and meets TIA-568-C.3, ISO/IEC 11801 Ed. 2.2, TIA-604-3 (FOCIS-3), and TIA-604-10 (FOCIS-10) performance standards

Panduit's Opti-Core OM4 platform is engineered for ultra-low insertion loss performance—typically 0.15 to 0.25 dB per mated connector pair, well below the 0.35 dB TIA-568-C.3 maximum for multimode duplex connectors—giving you headroom to extend reach, accommodate additional mated pairs in a permanent link, or tolerate connector wear over the life of the installation without exceeding your channel loss budget. The uniboot LC housing consolidates the transmit and receive fibers into a single compact boot with a shared outer jacket strain relief, cutting the connector footprint at your patch panel or switch port in half compared to traditional dual-simplex LC cords with separate boots. This matters when you're filling a 1U high-density panel with 24 or 48 duplex LC ports and every millimeter of working clearance counts for cable bend radius management, airflow around faceplate openings, and access to adjacent ports during adds or troubleshooting. The integrated pull-boot tab—color-coded and textured for grip—lets you extract the connector from a densely populated panel using one hand without applying force to the fiber or ferrule, a design feature that prevents the fiber-bending and end-face damage that occurs when installers pull on the jacket or yank connectors out at an angle. For polarity reversal (swapping the A and B fiber positions to correct a transmit/receive mismatch), you can release the internal retention clip, rotate the fiber pair 180 degrees inside the uniboot housing, and re-seat the clip without re-terminating the cable or replacing it with a reversed-polarity variant—saves time during troubleshooting and eliminates the need to stock multiple polarity configurations in your onsite spares inventory.

Deploy the FZ2RPU1U1NNM020 in data center horizontal distribution between equipment distribution area (EDA) top-of-rack or end-of-row switches and zone distribution enclosures or server NICs, in main distribution area (MDA) to horizontal distribution area (HDA) backbone interconnects where OM4 multimode fiber provides cost-effective 10G to 100G transport over distances up to 150 meters, or as cross-connects in telecommunications rooms serving 10GBASE-SR links to access switches, wireless controllers, or IP camera NVRs. The 20-meter length covers most intra-floor rack-to-rack runs and structured cabling horizontal links from in-floor zone enclosures to overhead telecommunications room panels—long enough to route through cable tray, around hot/cold aisle containment barriers, and down vertical cable managers without splicing or mid-span connectors, short enough to avoid excessive slack coils that complicate pathway management and waste available fill capacity in cable trays and ladder rack. The plenum-rated OFNP jacket is required for installation in air-handling spaces—drop ceilings, raised floors, HVAC return plenums, or any space used for environmental air circulation—where NEC Article 770.113 or local electrical code mandates low-flame-spread, low-smoke-production cable. If you're pulling cable through a return-air plenum above a suspended ceiling in a commercial office building, hospital, university, or anywhere the ceiling space is used for HVAC return without dedicated ductwork, this OFNP jacket rating is code-required; riser (OFNR) or general-purpose (OFNG) jackets do not meet the UL 910 Steiner Tunnel flame-spread and optical-density smoke limits for plenum spaces and will fail inspection. Pair this cable with plenum-rated fiber enclosures, splice trays, and cable management hardware to maintain continuous plenum compliance throughout the horizontal pathway.

The aqua jacket color conforms to TIA-598-D color coding for OM4 50/125μm laser-optimized multimode fiber, providing instant visual identification in mixed-fiber installations where OM3 (aqua with orange historically, now aqua), OM2 (orange), OM1 (orange or slate), and single-mode (yellow) cables may coexist in the same cable tray or patch panel. This color differentiation reduces the risk of cross-connecting incompatible fiber types—a common issue during MACs when a technician under time pressure grabs the wrong patch cord from a shared spares kit and inadvertently links an OM4 transceiver to an OM1 permanent link, creating a loss budget overrun or modal bandwidth mismatch that causes intermittent errors or link failure under load. In greenfield OM4 installations, the aqua jacket also simplifies documentation and labeling—every aqua cable is OM4, every OM4 link gets an aqua patch cord, and the color itself becomes a secondary verification point during acceptance testing or post-move troubleshooting. The LC connector interface is the de facto standard for enterprise and data center multimode fiber—supported by virtually every 10G/25G/40G/100G transceiver platform from Cisco, Arista, Juniper, Dell, HPE, and white-box switch vendors—ensuring you won't encounter compatibility issues or need adapter hardware to interface with active equipment. LC's small form factor (half the size of SC) and push-pull latching mechanism make it ideal for high-density applications where you're packing 144 or more fibers into a 1U panel and need reliable retention without the bulky squeeze-tab or bayonet mechanisms found on legacy connector types.

The FZ2RPU1U1NNM020 ships with factory certification to TIA-568-C.3 (commercial building telecommunications cabling standard), ISO/IEC 11801 Edition 2.2 (international generic cabling standard), TIA-604-3 (FOCIS-3 SC/LC connector intermateability and performance), and TIA-604-10 (FOCIS-10 uniboot LC connector geometry and performance), meeting the procurement and installation requirements for federal government projects (GSA schedules), military installations (DoD UFC 3-580-01 telecommunications infrastructure), healthcare facilities (Joint Commission structured cabling standards), and commercial projects with performance-based specifications. Each cord is individually tested for insertion loss (IL), return loss (RL), and connector endface geometry at the factory, with test results traceable to the manufacturing lot—eliminates the variability, labor cost, and rework risk associated with field termination using epoxy-and-polish or mechanical splice connectors, and ensures day-one performance that won't degrade your channel loss budget or cause a failed OTDR certification test during post-install acceptance. RoHS compliance (Directive 2002/95/EC restrictions on hazardous substances) meets procurement mandates for EU projects, LEED-certified green buildings, and enterprise IT organizations with environmental sustainability policies that restrict lead, mercury, cadmium, and brominated flame retardants in purchased equipment. This is the patch cord you specify when the structured cabling SOW calls out OM4 multimode fiber, the equipment room layout demands space-efficient uniboot connectors to maximize usable panel density, the building code or AHJ requires plenum rating for above-ceiling installation, and the project spec references TIA-568-C.3 or ISO/IEC 11801 compliance—no field modifications, no substitutions, no ambiguity on code compliance or performance certification.

Specifications
Product Type: Fiber Optic Patch Cord
Brand: Panduit
MPN: FZ2RPU1U1NNM020
Sub-Brand: Opti-Core
Fiber Type: OM4 Multimode
Fiber Diameter: 50/125 μm
Number of Fibers: 2
Connector 1 Type: LC Duplex Uniboot
Connector 2 Type: LC Duplex Uniboot
Cable Length: 20 m (65.62 ft)
Cable Color: Aqua
Jacket Rating: Plenum (OFNP)
Insertion Loss: Ultra Low (typically
Boot Type: Pull-Boot Uniboot
Polarity: Field-Reversible
Standards Compliance: TIA-568-C.3, ISO/IEC 11801, TIA-604-3, TIA-604-10
Environmental Compliance: RoHS (Directive 2002/95/EC)
UPC: 061305680774
Package Quantity: 1
Carton Quantity: 10
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources