Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit FRXTP77Y001F021 12-Fiber OM3 Plenum Pre-Terminated Trunk Cable
The Panduit FRXTP77Y001F021 is a 21-foot 12-fiber OM3 multimode plenum-rated trunk cable engineered for rapid deployment in data centers, telecommunications rooms, and enterprise network infrastructure. This Opti-Core® pre-terminated assembly eliminates field termination, delivering factory-tested performance with Method B polarity for duplex LC connectivity supporting 10GBASE-SR and 40/100G Ethernet applications up to 300 meters. Plenum (OFNP) construction meets fire safety requirements for installation in air-handling spaces while TIA-568.3-D and ISO/IEC 11801 compliance ensures interoperability across structured cabling ecosystems.
Key Features
- 12-Fiber OM3 Multimode Core: 50/125µm laser-optimized fiber supports 10GBASE-SR at 300m and 40/100GBASE-SR4 at 100m with VCSEL transceivers
- Factory Pre-Terminated Assembly: Eliminates on-site fusion splicing and connector polishing, cutting installation time by 70% and removing field termination error risk
- Plenum Fire Rating (OFNP): Low-smoke zero-halogen jacketing meets NEC Article 770 requirements for installation above drop ceilings and in return-air plenums without conduit
- Method B Polarity Design: Universal pinout ensures proper transmit-receive fiber mapping in duplex LC applications without crossover adapters or custom documentation
- 21-Foot Engineered Length: Pre-measured for inter-rack connections, top-of-rack to end-of-row runs, and floor-to-ceiling vertical pathways in typical enterprise installations
- TIA-568.3-D and ISO/IEC 11801 Compliant: Verified insertion loss and return loss performance meets or exceeds industry standards for commercial building telecommunications cabling
- Opti-Core® Enterprise Grade: Panduit's structured cabling platform with lifetime warranty coverage and technical support for mission-critical network infrastructure
Pre-terminated fiber trunk cables solve the deployment speed problem in retrofit and expansion projects where downtime windows are measured in hours, not days. Unlike field-terminated solutions that require skilled fusion-splicing technicians, epoxy-cure time, and per-connector testing, this assembly ships ready to install—pull the cable, plug both ends, verify link light, and move to the next run. The 12-fiber count supports six duplex LC connections, a common breakout for top-of-rack switches connecting to spine aggregation layers or for distributing building backbone capacity across multiple IDFs. Method B polarity maintains TX-RX pairing across straight-through duplex patch cords, eliminating the documentation overhead and troubleshooting complexity associated with custom crossover pinouts.
OM3 multimode fiber remains the cost-performance standard for enterprise data centers operating 10G and 40G Ethernet over distances under 300 meters. The 50/125µm core works with affordable 850nm VCSEL optics—the same transceiver technology in most enterprise switches—while the aqua jacket color-coding (industry standard for OM3) prevents accidental cross-patching with OM1/OM2 legacy fiber that cannot support 10G speeds. Plenum construction addresses fire marshal requirements in the 80% of commercial buildings where cable pathways share airspace with HVAC return ducts. The low-smoke zero-halogen compounds limit toxic gas and particulate generation during fire events, a life-safety consideration that also protects sensitive electronics in the same plenum space from corrosive combustion byproducts.
The 21-foot length targets installations where standard 3-meter and 5-meter patch cords are too short but 30-meter backbone runs are overkill—common scenarios include cross-connects between adjacent racks in the same row, vertical riser drops from overhead cable trays to rack tops, or horizontal pathways spanning one or two structural bays in office environments. Panduit engineers these assemblies with pull-tension reinforcement and bend-radius protection boots, recognizing that trunk cables experience rougher handling during installation than plug-and-play patch cords. Every assembly undergoes automated optical testing at the factory; the included test report documents insertion loss per fiber pair, giving you baseline performance data for future troubleshooting and change-management records.
Backed by Panduit's manufacturer warranty and designed for integration with Panduit fiber enclosures, patch panels, and LC cassettes, the FRXTP77Y001F021 fits structured cabling deployments where installation speed, code compliance, and documented performance are non-negotiable. Whether you're building out a new server row, adding capacity to an existing backbone, or executing a maintenance window with a two-hour fiber replacement SLA, this trunk cable delivers the reliability and ease of deployment that separates professional infrastructure from ad-hoc patchwork.
Panduit FRXTP77Y001F021 12-Fiber OM3 Plenum Trunk Cable
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology