Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AR7150B2
Condition: New
Write a Review 32% OFF

APC by Schneider Electric Netshelter SX GEN2 42U 750MM Wide Perforated Split Doors Black - AR7150B2

APC by Schneider Electric AR7150B2 NetShelter SX Gen2 42U 750mm Perforated Split DoorOverviewThe AR7150B2 is a factory-replacement perforated split fr…

$1,020.00 $697.99 SAVE $322
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Netshelter SX GEN2 42U 750MM Wide Perforated Split Doors Black - AR7150B2

$1,020.00
$697.99

Overview

SKU: AR7150B2
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AR7150B2 NetShelter SX Gen2 42U 750mm Perforated Split Door

Overview

The AR7150B2 is a factory-replacement perforated split front door for the APC NetShelter SX Gen2 42U 750mm-wide rack enclosure. If your existing door is damaged, missing, or you are retrofitting a previously open-frame cabinet into a secured enclosure, this is the direct-fit replacement — no cutting, no fabrication, no adapter hardware required. The door ships in black to match standard NetShelter SX Gen2 deployments and includes all mounting hardware and keys out of the box.

At 75.4 inches tall and constructed from 16-gauge steel, this door is built to the same structural spec as the OEM door it replaces. At 27.6 lb, it is substantial enough for a data center or server room environment but manageable for a two-person installation. For procurement teams, the AR7150B2 carries both TAA and BAA compliance via COTS designation, which means it qualifies for U.S. federal, state, and municipal purchasing programs without a waiver process.

Key Features

  • 16-Gauge Steel Construction: The front door is stamped from 16-gauge steel — thick enough to resist incidental impact from cart traffic or tooling in active server rooms without deforming around the hinges or latch points. Thinner-gauge aftermarket doors flex and wear at the hinge mounts over time; this spec matches the original enclosure build.
  • Perforated Split Door Design: The perforated panel promotes passive airflow through the front of the enclosure, reducing the thermal delta between intake and ambient air. A split-door design lets you open one half without swinging the full 75.4-inch panel — useful in tight aisles where clearance is limited.
  • 75.4-Inch Height (1,915mm): Dimensioned specifically for the 42U NetShelter SX Gen2 enclosure. This is not a universal fit — verify your enclosure model before ordering. Incorrect door height results in misaligned hinge points and an unusable latch.
  • TAA and BAA Compliant via COTS: Both Trade Agreements Act and Buy American Act compliance are confirmed for this SKU. Federal integrators and government IT contractors can specify the AR7150B2 directly on procurement orders without seeking a product-specific waiver — a meaningful difference on time-sensitive government projects.
  • Black Finish: Matches standard NetShelter SX Gen2 enclosure aesthetics. If your deployment uses the white or gray variant of the enclosure, confirm the correct finish SKU before ordering — a color mismatch in a visible equipment room is a nuisance that requires a return.
  • Complete Hardware Kit Included: Ships with the door handle, door mounting hardware, installation guide, and keys. No separate hardware order is needed to complete the installation.

Integration and Compatibility

The AR7150B2 is designed exclusively for the APC by Schneider Electric NetShelter SX Gen2 42U 750mm-wide enclosure line. It is not compatible with 600mm-wide variants, older NetShelter SX Gen1 frames, or NetShelter EP/VX enclosures. Before ordering, confirm the enclosure width (750mm) and generation (Gen2) stamped on the existing frame label. This door is also not compatible with NetShelter SX enclosures of other rack unit heights (e.g., 24U, 48U).

For facilities managing a large installed base of network rack enclosures, keeping a spare door on hand for the 750mm Gen2 footprint avoids extended lead times when physical security or environmental protection is urgently needed after door damage. Pair with compatible APC rack accessories such as side panels or roof blanking panels if you are building out a fully enclosed equipment bay. For guidance on selecting the right enclosure components for your infrastructure, consult a rack enclosure selection guide before finalizing your order.

What's in the Box

  • 1x Perforated split front door (AR7150B2, black)
  • 1x Door handle
  • 1x Door mounting hardware kit
  • 1x Installation guide
  • 1x Key set

Frequently Asked Questions

Q: Which APC enclosures is the AR7150B2 compatible with?

A: The AR7150B2 is designed for the APC NetShelter SX Gen2 42U 750mm-wide rack enclosure. It is not compatible with 600mm-wide frames, Gen1 enclosures, or other NetShelter families (EP, VX). Confirm your enclosure's width and generation before ordering.

Q: Is the AR7150B2 TAA and BAA compliant?

A: Yes. The AR7150B2 carries both Trade Agreements Act (TAA) and Buy American Act (BAA) compliance via COTS designation, making it eligible for U.S. federal, state, and municipal procurement without a product-specific waiver.

Q: What gauge steel is the AR7150B2 door?

A: The door is constructed from 16-gauge steel, matching the structural specification of the original OEM door on the NetShelter SX Gen2 enclosure.

Q: Does the AR7150B2 come with mounting hardware and keys?

A: Yes. The package includes the door handle, door mounting hardware, installation guide, and keys — everything needed for a complete installation without a separate hardware order.

Q: What are the dimensions and weight of the AR7150B2?

A: The door stands 75.4 inches (1,915mm) tall and weighs 27.6 lb (12.5 kg). The shipping package measures approximately 79.1 in L × 19.09 in W × 7.3 in H and ships at 46.3 lb.

Q: Is the AR7150B2 rack-mountable?

A: No. The AR7150B2 is a replacement door panel for the NetShelter SX Gen2 enclosure — it is not itself rack-mountable and does not occupy rack units inside a cabinet.

Karl Wilson
Karl Wilson

The AR7150B2 is one of those procurement items that looks trivial until you actually need it — and when you do, lead time matters. The 16-gauge steel construction and 75.4-inch height are the two specs that matter most here: they tell you this is an exact-fit OEM-spec replacement, not a generic aftermarket panel that requires shimming at the hinge plates or won't seat the latch properly.

Technical Highlights:

  • 16-Gauge Steel: Matches the original NetShelter SX Gen2 door spec. Aftermarket doors frequently use 18- or 20-gauge, which flexes noticeably at the hinge mounts under repeated use and accelerates wear on the latch mechanism.
  • Perforated Split Design: Perforation promotes passive front-to-back airflow without a powered plenum. The split configuration means one half can be opened in a 24-inch aisle without swinging into adjacent equipment rows — a real constraint in high-density data centers.
  • TAA/BAA via COTS: Both compliance marks are confirmed for this SKU. On federal or state government projects, this eliminates the paperwork cycle for a product-specific waiver — which can delay procurement by weeks on smaller orders.

Deployment Considerations:

  • Verify enclosure width (750mm) and generation (Gen2) from the frame label before ordering — the 600mm-wide NetShelter SX Gen2 uses a different door SKU, and the hinge spacing is not interchangeable.
  • At 27.6 lb, this is a two-person install in a live rack row. The shipping package runs 79.1 inches long and 46.3 lb — confirm receiving dock clearance and elevator dimensions before scheduling delivery in a multi-floor facility.

The AR7150B2 is the correct spec for federal data centers and government-contractor server rooms running the NetShelter SX Gen2 750mm platform where TAA/BAA compliance is a hard procurement requirement — not just a preference.

Specifications
Product Or Component Type: Door
Provided Equipment: Door handle Door mounting hardware Installation guide Key(s)
Color: Black
Dimensions: 75.4 in (1915 mm)
Weight: 27.6 lb(US) (12.5 kg)
Mounting Preference: No preference
Mounting Mode: Not rack-mountable
Marking: 16 gauge front door
Unit Type Of Package 1: PCE
Nbr. Of Units In Pkg: 1
Package 1 Height: 7.3 in (18.5 cm)
Package 1 Width: 19.09 in (48.5 cm)
Package 1 Length: 79.1 in (201 cm)
Package Weight(Lbs: 46.3 lb(US) (21 kg)
Certifications: TAA Compliant BAA Compliant via COTS
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources