Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit C2CAC04ABWPAW1 Net-Contain 400mm Blanking Panel

Overview

The Panduit C2CAC04ABWPAW1 is a 400mm blanking panel from the Panduit Net-Contain line, engineered to seal unused rack openings in N-type and S-type cabinets. Blanking panels do one specific job — prevent hot exhaust air from recirculating into the cold aisle — and this panel is sized and rated for the cabinet families it targets. If you're building or expanding a structured cabling or network enclosure deployment and leaving open rack units, you're actively degrading the thermal containment that your cabinet investment was meant to deliver. The C2CAC04ABWPAW1 closes that gap.

Key Features

  • 400mm Panel Width: Matched to the internal bay width of Panduit N- and S-type cabinets — drop-in fit without trimming or shimming. Using a mismatched panel leaves air bypass gaps at the edges, which defeats the purpose of containment entirely.
  • Net-Contain System Integration: Designed as part of Panduit's Net-Contain thermal management ecosystem, so it coordinates with containment doors, ducting, and airflow partitions in the same product family. Mixing blanking panels from outside the family risks dimensional mismatches that show up only after the rack is loaded.
  • Blanking Function — Airflow Discipline: Sealing open rack units forces cool supply air to pass through active equipment rather than short-circuiting to the return path. In high-density rows, open 1U or 2U gaps can raise inlet temperatures at servers above ASHRAE limits — a problem that a correctly specified blanking panel eliminates at very low cost relative to the thermal risk.
  • Commercial-Grade Construction: Built to Panduit's commercial infrastructure standards, consistent with the rest of the Net-Contain line used in enterprise data centers and network rooms.

Integration and Compatibility

The C2CAC04ABWPAW1 is specified for N-type and S-type Panduit cabinets at the 400mm bay dimension. Before ordering, confirm your cabinet's internal usable width — Panduit's N- and S-series are the correct chassis families. This panel is a component of the broader rack and cabinet accessories ecosystem; pair it with Panduit cable management and containment hardware for a complete airflow solution. Consult Panduit's Net-Contain configuration guides to verify unit-height and mounting compatibility with your specific cabinet model.

Frequently Asked Questions

Q: Which cabinet types is the C2CAC04ABWPAW1 compatible with?

A: The C2CAC04ABWPAW1 is designed for Panduit N-type and S-type cabinets. Verify your cabinet's internal bay width against the 400mm panel dimension before ordering.

Q: What is the purpose of a blanking panel in a rack cabinet?

A: Blanking panels seal unused rack unit openings to prevent hot exhaust air from recirculating back to equipment air intakes. This maintains thermal containment and protects active equipment from elevated inlet temperatures.

Q: Is the C2CAC04ABWPAW1 part of a larger thermal management system?

A: Yes — it belongs to Panduit's Net-Contain product line, which includes containment doors, airflow partitions, and ducting components designed to work together in N- and S-type cabinet installations.

Q: Can this blanking panel be used with third-party or non-Panduit cabinets?

A: The panel is engineered and dimensioned for Panduit N- and S-type cabinets. Compatibility with third-party enclosures is not confirmed by available evidence — measure your cabinet's internal bay width and compare to the 400mm spec before attempting a cross-brand installation.

Marty Allison
Marty Allison

The C2CAC04ABWPAW1 is one of those components that gets overlooked during cabinet builds and causes thermal headaches six months after commissioning. It's a 400mm blanking panel from Panduit's Net-Contain line — purpose-built for N- and S-type cabinets, and the fit precision matters more than most buyers expect.

Technical Highlights:

  • 400mm Width: Matched to the N- and S-type cabinet bay — no field trimming, no edge gaps that allow bypass airflow to sneak through.
  • Net-Contain System Membership: Because it's part of the Net-Contain family, it dimensionally coordinates with containment doors and partitions in the same line, avoiding the stack-up tolerance issues you get mixing blanking panels across brands.
  • Airflow Discipline: Every unsealed rack unit is a low-resistance path for hot return air to short-circuit back to equipment inlets. A correctly installed blanking panel eliminates that path at near-zero cost relative to the thermal damage it prevents.

Deployment Considerations:

  • Confirm N-type or S-type cabinet designation before ordering — the 400mm internal bay dimension is the key match point, and Panduit's other cabinet families may not share it.
  • Blanking panels should be installed from the bottom of the rack upward, filling all unused Us before powering up high-density switching or compute gear — retrofitting after loading a rack is significantly harder.

The C2CAC04ABWPAW1 is the right call for enterprise network rooms and data center rows running Panduit N- or S-type cabinets where airflow containment is part of the design spec — not an afterthought.

Specifications
Component Type: Blanking Panel
Manufacturer: Panduit
Line: Net-Contain
Q&A
Reviews

Panduit N AND S TYP CAB 400MM BLANKING - C2CAC04ABWPAW1

$476.22
$285.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources