Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv I10175L Basic Upgradeable Vertical Rack PDU

The Vertiv I10175L is a 20A, 208V vertical rack power distribution unit with 26 locking receptacles — a solid fit for high-density IT cabinets where power security and a clear upgrade path matter. Built on Vertiv's PowerIT rPDU platform under the Geist Upgradeable architecture, the I10175L ships as a basic (non-monitored) unit but accepts any Interchangeable Monitoring Device (IMD) without taking the cabinet offline. If your organization expects to add per-outlet metering or environmental monitoring later, this is the model to buy now rather than swap out later.

Overview

Vertiv designed the PowerIT rPDU line around the reality that data center and IT closet power requirements evolve. The I10175L sits in the rack power distribution category as a Basic Upgradeable unit — meaning it ships without active monitoring electronics, which keeps the unit price lower, but the Geist hot-swap IMD slot means you can field-install a metering or monitoring module at any point without a power outage or hardware change. For environments that need reliable outlet density today and telemetry tomorrow, that tradeoff is worth understanding before you order.

The unit is manufactured in the USA, TAA Compliant, and Buy American Act COTS Compliant — relevant for federal agency deployments, DoD integrators, or any project with domestic-sourcing requirements on capital equipment. Browse the full Vertiv power and infrastructure catalog for complementary products including UPS systems and thermal management.

Key Features

  • 26 Locking Receptacles (20x IEC C13 + 6x IEC C19): Every outlet uses Vertiv's U-Lock locking mechanism — cords require a deliberate twist-and-pull to release, which eliminates accidental disconnections from cable management operations or vibration. The C19/C13 mix covers both standard 1U server power supplies and high-draw equipment like blade chassis, storage arrays, or dense GPU nodes that require C19. Orange circuit-ID color coding on all locking collars makes visual circuit tracing fast in dense, multi-circuit cabinets.
  • 20A / 208V / 3.3kW Load Capacity: At 3.3kW on a single 20A circuit, this unit supports a moderately loaded rack — typically 12–18 standard 1U servers at idle or 6–10 at full compute load. If your rack profile exceeds 3.3kW per circuit, plan for a second PDU or consider a higher-amperage model in the Vertiv line. The NEMA L6-20P twistlock plug physically prevents accidental connection to incompatible 120V circuits, protecting connected equipment.
  • Geist Upgradeable IMD Hot-Swap Architecture: The single most operationally useful spec on the I10175L. Adding inlet-level power metering or a full environmental monitoring module requires no tools, no downtime, and no recabling — the IMD slides into the integrated slot on the active unit. For phased deployments where monitoring budgets come in a separate procurement cycle, this eliminates the cost and risk of a full PDU swap.
  • Scrolling / Rotatable Digital Display: The built-in display rotates to remain readable regardless of how the unit is oriented in the cabinet — relevant for installations where front-access labeling conventions vary. No IMD required for basic load visibility at the unit itself.
  • 66-inch Vertical Form Factor (1683mm): Designed for full-height 42U cabinets with toolless mounting hardware. Center-to-center spacing options of 61.25in and 64.75in accommodate standard cabinet rail configurations without drilling or adapter plates. The 2.0in x 2.0in cross-section keeps the unit flush against the cabinet side rail, preserving full-width cable management space.
  • 10ft / 3m Power Cord, Bottom-Front Entry: The bottom-front power entry location works well in most raised-floor environments where power whips rise from underfloor distribution. The 12/3 wire gauge at 10ft handles the 20A load without derating concerns. If your power source is overhead or at a different drop point, verify cord reach before committing to cabinet placement.
  • 60°C / 140°F Maximum Operating Temperature: Rated for ambient conditions well above typical data center setpoints (ASHRAE A1: 15–32°C, A2: 10–35°C). This rating matters in poorly cooled telecom closets, edge deployments, or industrial environments where HVAC is intermittent — the PDU won't derate or alarm-out at elevated ambient temperatures that would stress lesser hardware.
  • UL & c-UL Listed (62368-1), RoHS, FCC Part 15 Class A: UL 62368-1 is the current safety standard for audio/video and IT equipment — not the legacy UL 1950 — which means this unit meets current lab and data center compliance requirements. RoHS compliance is relevant for EU deployments or corporate environmental mandates. FCC Part 15 Class A confirms it won't inject EMI into adjacent network or storage equipment.
  • 5-Year Limited Warranty + 100% Factory Testing: Every I10175L is individually tested before shipment. The 5-year coverage window aligns with typical server refresh cycles, which matters when procurement is amortizing the PDU cost alongside the rack hardware it supports.

Integration and Compatibility

The I10175L operates on a single 200–240V input at 50 or 60Hz, compatible with global data center power infrastructure. The NEMA L6-20P plug is standard for 208V single-phase circuits in North American facilities — verify your PDU panel or in-row power strip is spec'd at 20A before install. For environments standardizing on rack infrastructure with future monitoring needs, Vertiv's IMD module ecosystem includes options for inlet metering, environmental sensing, and outlet switching — all hot-swappable into this chassis without procurement of a new PDU. The U-Lock receptacles are compatible with standard IEC C14 and IEC C20 plugs fitted with locking retention collars; standard non-locking plugs also seat and power normally, but without the retention benefit.

For larger deployments requiring per-outlet switching or three-phase input, compare against higher-tier models in Vertiv's PowerIT rack PDU line before finalizing your configuration. TAA and Buy American Act compliance makes the I10175L eligible for GSA Schedule purchases and federal solicitations with domestic-content requirements — confirm with your contracting officer for specific project applicability.

Frequently Asked Questions

Q: Can the I10175L be upgraded to a metered or monitored PDU after installation?

A: Yes. The I10175L uses Vertiv's Geist Upgradeable architecture with a hot-swap IMD slot. You can add an Interchangeable Monitoring Device for inlet metering or full environmental monitoring while the unit remains energized and in service — no downtime, no recabling required.

Q: What is the plug type and input voltage for the I10175L?

A: The I10175L uses a NEMA L6-20P twistlock plug rated at 20A, 200–240V (208V typical in North American facilities). It is not compatible with standard 120V NEMA 5-15 or 5-20 circuits — verify your panel circuit type before installation.

Q: Is the I10175L TAA compliant?

A: Yes. The I10175L is manufactured in the USA and is both TAA Compliant and Buy American Act COTS Compliant, making it eligible for federal and defense procurement under domestic-sourcing requirements.

Q: What is the warranty on the I10175L?

A: Vertiv provides a 5-year limited warranty on the I10175L. Every unit is 100% factory tested before shipment.

Q: Will standard IEC C14 and C20 plugs work in the locking receptacles?

A: Standard non-locking IEC C14 and C20 plugs will seat and power normally in the U-Lock receptacles. However, the locking retention feature only activates with compatible locking-style plugs — without them, cords can be pulled free without the deliberate twist-and-release action that prevents accidental disconnection.

Q: What is the maximum load capacity and how many outlets does the I10175L provide?

A: The I10175L is rated at 3.3kW (at 208V) on a single 20A circuit. It provides 26 total receptacles: 20 locking IEC C13 outlets and 6 locking IEC C19 outlets, all on a single circuit with orange U-Lock color coding for circuit identification.

James Everett
James Everett

The I10175L is one of the more sensible buys in the Vertiv PowerIT line for integrators who are speccing cabinets today under a phased monitoring budget. The Geist hot-swap IMD slot is the spec I keep coming back to — it means you're not locked into a basic PDU forever, and you're not paying for monitoring hardware you don't need on day one. I've seen too many deployments where the team bought a permanent basic PDU to save $80, then spent $600 and half a maintenance window replacing it 18 months later when the customer added DCIM or remote NOC oversight.

Technical Highlights:

  • 26 Locking Outlets (20x C13 / 6x C19): The U-Lock mechanism requires deliberate rotation to release — in a cabinet with active cable management and multiple technicians, that friction is a feature, not an annoyance. Orange circuit color coding on all 26 locking collars is genuinely useful when you're tracing circuits in a populated 42U cabinet at 2am.
  • 3.3kW at 208V, Single 20A Circuit: Realistic for a mid-density compute rack. This unit won't serve a GPU cluster or a fully loaded blade chassis on its own — those environments need dual-corded 30A or 3-phase distribution. But for standard 1U/2U server rows, 3.3kW per PDU is a comfortable budget with headroom for startup surge.
  • 60°C Maximum Operating Temperature: Higher than most competing units in this class, which typically rate to 45°C. That 15-degree margin matters in edge sites, manufacturing floor closets, or any environment where HVAC isn't purpose-built for IT — the PDU won't become the failure point when ambient climbs.

Deployment Considerations:

  • Bottom-front power entry at 10ft cord length: measure the drop from your floor-mount power whip or PDU panel to the cabinet's rear cable entry before finalizing cabinet placement. A 10ft cord is generous in most raised-floor environments but can fall short in overhead-busway or long-run configurations.
  • No over-current protection on the unit itself — branch protection must come from the upstream panel or PDU. If your facility's panel breakers are shared across multiple cabinets, the absence of local OCP means a fault on this PDU could affect adjacent equipment before the upstream breaker trips.

The I10175L is a strong fit for federal, DoD, or GSA-scheduled deployments where TAA and Buy American Act compliance are hard requirements — the domestic manufacturing origin is documented and certified, not a label claim. It's equally well-suited for mid-size data center buildouts where the monitoring decision is deferred but the cabinet infrastructure needs to be in place now.

Specifications
Part Number: I10175L
Model Number: MN01X4B0-26PJ68-2TL6A0A10-S
Category: Basic Upgradeable
Power Configuration: 20A, 208V, 3.3kW
Physical Configuration: 66in / 1683mm, Vertical
Input Voltage: 200-240V
Input Current: 20A
Load Capacity: 3.3kW
Frequency: 50/60Hz
Power Cable Length: 10ft / 3m
Plug Type: NEMA L6-20P Twistlock
Total Receptacles: 26
Receptacle Type 1: Locking IEC C13
Receptacle Quantity 1: 20
Receptacle Type 2: Locking IEC C19
Receptacle Quantity 2: 6
Maximum Operating Temperature: 60C / 140F
Chassis Dimensions: 66.25in x 2.0in x 2.0in
Shipped Weight: 15lbs (6.8kg)
Warranty: 5-year limited warranty
Certifications: UL & c-UL Listed 62368-1, RoHS Compliant, FCC Part 15 Class A
Country of Origin: USA, TAA Compliant, Buy American Act COTS Compliant
Q&A
Reviews

Vertiv MN01X4B0-26PJ68-2TL6A0A10-S - I10175L

$963.00
$660.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources