Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv I10066 Metered Upgradeable Vertical Rack PDU

Overview

The Vertiv I10066 is a 20A, 120V vertical rack power distribution unit carrying model number MN01D4B0-24D203-2TL5A0A10-S — built for IT infrastructure teams that need real-time current visibility at the rack level without committing to a full monitored PDU budget today. Twenty-four NEMA 5-20R duplex receptacles feed standard server and networking gear, while a local LED display gives you live input current, watts, volt-amps, power factor, and voltage without opening a browser or polling an SNMP agent. The design's defining trait is its hot-swap rack power distribution upgrade path: when your team is ready to move from metered to fully monitored, you swap in Vertiv's Interchangeable Monitoring Device (IMD) and gain network-addressable monitoring without replacing the PDU chassis.

Key Features

  • 24 NEMA 5-20R Duplex Outlets: Twenty-four 120V/20A receptacles arranged in duplex pairs cover a fully populated 42U rack with room to spare. Every outlet runs at 120V, so standard 1U/2U servers, switches, and storage shelf power supplies connect without adapters.
  • ANSI C12.1 / IEC 62053-21 Metering at 1% Accuracy: The onboard current sensor meets both the ANSI and IEC commercial metering standards at 1% accuracy class — not the loose ±2–5% tolerance common on entry-level PDUs. That precision matters when you're managing a rack to an 80% load target: a 1% meter tells you 15.8A; a 5% meter could read anywhere from 15.2A to 16.8A on the same actual load.
  • Phase-Level Monitoring (kWh, W, VA, PF, V, A): The single-phase input is measured across all six parameters simultaneously. Power factor visibility in particular is useful in environments with switching power supplies that draw non-unity PF — you'll see true watts versus volt-amps and can right-size your UPS capacity accordingly.
  • Local Scrolling LED Display: High-visibility LED readout puts current draw at eye level without requiring network access or a laptop. Useful during initial rack commissioning and during incident response when network management may be down.
  • Hot-Swap IMD Upgrade Path: The Vertiv PowerIT Upgradeable platform lets you field-upgrade this metered unit to a monitored rPDU by inserting the appropriate IMD module — no downtime, no recabling, no PDU swap. That means you can deploy I10066 units now and activate per-outlet or environmental monitoring later as the budget allows.
  • 10 ft / 3m L5-20P Power Cord: The included 12/3 AWG cord with NEMA L5-20P twistlock plug reaches most top-of-rack and bottom-of-rack power panels in standard data center layouts. The twistlock connector prevents accidental disconnection under vibration or lateral cable pressure.
  • 66.25in Vertical Form Factor: At 2.0in × 2.0in cross-section and 66.25in length, the I10066 mounts vertically in the rear of a standard rack using toolless hardware with 61.25in or 64.75in center-to-center spacing — covering the two most common rail spacings without adapters.
  • Maximum Operating Temperature 60°C / 140°F: Rated to 60°C, this unit handles high-density hot-aisle environments and edge deployments where ambient temperatures exceed data center norms. Most comparable units cap at 45°C; the 60°C ceiling gives meaningful headroom for poorly cooled or transitional spaces.
  • TAA Compliant, Buy American Act COTS Compliant, Made in USA: Manufactured in the United States and TAA compliant — a hard requirement for federal, DoD, and many state/local government procurement vehicles. FCC Part 15 Class A conformance covers commercial IT environments.
  • UL & c-UL Listed 62368-1, RoHS Compliant: Dual-listed to the current ITE safety standard (62368-1, which replaced the legacy 60950-1 and 60065 frameworks). RoHS compliance covers hazardous substance restrictions for deployments under EU/UK environmental requirements.
  • 5-Year Limited Warranty: Vertiv's five-year warranty on the I10066 is notably longer than the one- to three-year terms common on competing metered PDUs. In a fixed infrastructure asset that may sit in a rack for a decade, that coverage window matters.

Integration and Compatibility

The I10066 connects via NEMA L5-20P twistlock to a 20A branch circuit — confirm your panel or in-row PDU provides a dedicated 20A circuit before deployment. With 24 outlets drawing simultaneously, derate to 80% of rated capacity (16A / 1.52kW) per NEC guidance for continuous loads. The unit ships with no integral overcurrent protection, so upstream breaker or fuse sizing at the panel is your primary protection. For environments that need per-outlet or environmental monitoring, pair this unit with Vertiv's IMD module rather than replacing it with a higher-tier metered and monitored rack PDU. If your rack power architecture runs dual-feed redundancy, note this is a single-input unit — redundant configurations require two PDUs on separate circuits, or a monitored variant with transfer switching capability. Review your data center power planning approach before finalizing single vs. dual-corded server ratios against this PDU's 24-outlet capacity.

Frequently Asked Questions

Q: Is the Vertiv I10066 TAA compliant and eligible for government procurement?

A: Yes. The I10066 is TAA Compliant, Buy American Act COTS Compliant, and manufactured in the USA. It also carries UL & c-UL Listed 62368-1 certification and FCC Part 15 Class A conformance, making it eligible for most federal and state government IT procurement vehicles.

Q: What is the warranty on the I10066?

A: Vertiv provides a 5-year limited warranty on the I10066.

Q: Can I upgrade the I10066 from metered to monitored without replacing the unit?

A: Yes. The I10066 is part of Vertiv's PowerIT Upgradeable platform. You can add network monitoring capability by hot-swapping in Vertiv's Interchangeable Monitoring Device (IMD) — no PDU replacement or recabling required.

Q: How many outlets does the I10066 provide, and what receptacle type?

A: The I10066 has 24 NEMA 5-20R duplex receptacles, all rated at 120V. The unit draws power via a 10ft cord with a NEMA L5-20P twistlock plug on a 20A, 120V circuit.

Q: How accurate is the current monitoring on the I10066?

A: The I10066 meets ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements — this is a commercial metering standard, not a loose estimate. It monitors input current, kWh, watts, VA, power factor, and voltage on the single-phase input.

Q: Does the I10066 have network connectivity built in?

A: No. In its base configuration, the I10066 is a metered PDU with local LED display only — no Ethernet port, no SNMP, no web interface. Network monitoring requires adding Vertiv's optional IMD module, which the Upgradeable platform supports via hot-swap.

Jerry Tildsen
Jerry Tildsen

The I10066 sits in a specific sweet spot I see often in mid-market data center builds: the team knows they want metering now and monitoring later, but they don't want to pay for network ports they won't activate for 12–18 months. Vertiv's hot-swap IMD architecture on this unit solves that cleanly — you install the I10066 today at metered-PDU price points, and when budget frees up you drop in an IMD without touching the outlet cabling or rescheduling a maintenance window.

Technical Highlights:

  • 1% Accuracy Metering (ANSI C12.1 / IEC 62053-21): This isn't a rough estimate — the I10066 measures to commercial utility metering standards. At a 16A derated load target, a 1% sensor gives you ±0.16A confidence versus ±0.8A at 5%; that's the difference between catching a creeping overload at 15.5A and missing it entirely.
  • 66.25in Vertical Chassis, 2.0in × 2.0in Profile: The narrow cross-section leaves rear-of-rack cable management space intact. Toolless mounting hardware covers both 61.25in and 64.75in center-to-center rail spacings — the two standards you'll encounter in APC, Vertiv, and Chatsworth cabinets — so no adapter kit is needed.
  • 60°C Maximum Operating Temperature: Most metered PDUs derate at 45°C. The I10066's 60°C ceiling covers high-density hot aisles, edge telco rooms, and industrial-adjacent deployments where you can't guarantee sub-40°C ambient conditions year-round.

Deployment Considerations:

  • The I10066 carries no integral overcurrent protection — size your upstream breaker to the circuit, and apply the 80% continuous-load derate (16A max for a 20A circuit) before calculating outlet assignments. With 24 outlets on a 16A derated budget, you're working with roughly 666mA per outlet if loaded uniformly — realistic for 1U servers but worth modeling before deployment.
  • This is a single-input, single-phase unit. If your rack design calls for dual-corded A/B redundancy, you'll need two I10066 units on separate 20A circuits — plan your cabinet power panel accordingly before rack layout is finalized.

For a government agency, university IT shop, or enterprise IT team standardizing on TAA-compliant infrastructure with phased monitoring rollouts, the I10066 is the right chassis to deploy at scale now and activate monitoring on selectively as budget permits — rather than overpaying for full monitoring on every PDU in the fleet from day one.

Specifications
Model Number: MN01D4B0-24D203-2TL5A0A10-S
Power Configuration: 20A, 120V, 1.9kW
Physical Configuration: 66in / 1683mm, Vertical
Plug Form: L5-20P
Receptacle Type: NEMA 5-20R
Receptacle Quantity: 24
Voltage: 100-120V
Current: 20A
VA per Input: 1.9kW (120V)
Frequency: 50/60Hz
Power Cable Length: 10ft / 3m
Maximum Operating Temperature: 60C / 140F
Chassis Dimensions: 66.25in x 2.0in x 2.0in
Shipped Weight: 15lbs (6.8kg)
Product Warranty: 5-year limited warranty
Agency Approvals: UL & c-UL Listed 62368-1, RoHS Compliant, FCC Part 15 Class A
Q&A
Reviews

Vertiv MN01D4B0-24D203-2TL5A0A10-S - I10066

$776.00
$532.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources