Vertiv MN01D1R1-08D203-3TL5A0H10-S - I10113
Rack-mountable power distribution unit (PDU) designed to provide reliable power to critical IT equipment within a data center or network closet
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv I10116L is a 1U horizontal rack PDU built for high-density data center and colocation environments where 3-phase power distribution and real-time load visibility are non-negotiable. Carrying the full model designation MN01D1R1-06L198-3TL21A0H10-S, this unit delivers 30A at 120/208V WYE (8.6kW at 208V) across six locking IEC C19 receptacles — the outlet type you want when server PSUs and UPS feeds need a mechanical retention mechanism to prevent accidental disconnection during cable management or maintenance. The local LED display lets rack technicians confirm load at a glance without pulling up a management interface, and the hot-swap upgradeable architecture means you can add full network monitoring capabilities later without swapping the PDU itself.
This unit ships from the USA and is TAA Compliant and Buy American Act COTS Compliant — relevant for federal deployments, government contractors, and any project with domestic-sourcing requirements. The Vertiv PowerIT rPDU line sits at the core of Vertiv's rack power distribution portfolio and is engineered for the operational realities of high-availability infrastructure environments.
The I10116L is designed for data centers, enterprise server rooms, and colocation cages running 3-phase WYE power infrastructure. The L21-30P plug connects to standard 30A 3-phase WYE distribution panels and PDU whips found in most North American colo and enterprise facilities. The six C19 outlets are compatible with C20 inlet server PSUs, UPS feeds, and KVM switches — essentially any device with a standard IEC C20 power inlet. The PDU's 100–120/200–240V WYE input range covers both 120V single-phase bypass scenarios and the primary 208V 3-phase deployment case. When your power requirements grow or management mandates shift, the hot-swap IMD slot accommodates Vertiv's network-enabled monitoring modules, integrating the PDU into DCIM and remote infrastructure management workflows without a hardware replacement. For rack-level power planning, pairing this PDU with a compatible UPS upstream ensures runtime protection alongside the load monitoring the I10116L provides. For guidance on matching PDU capacity to rack density, see the rack power planning guide.
Q: Is the Vertiv I10116L TAA compliant?
A: Yes. The I10116L is manufactured in the USA and is both TAA Compliant and Buy American Act COTS Compliant, making it eligible for federal, defense, and government-funded deployments with domestic-sourcing requirements.
Q: What is the warranty on the I10116L?
A: The I10116L carries a 5-year limited warranty from Vertiv.
Q: Can the I10116L be upgraded to a monitored (network-enabled) PDU later?
A: Yes. The upgradeable architecture supports hot-swap installation of a compatible Vertiv Interchangeable Monitoring Device (IMD), converting the unit from metered to monitored without removing it from the rack or interrupting power.
Q: What type of plug does the I10116L use and how long is the power cord?
A: The I10116L uses a NEMA L21-30P twistlock plug on a 10ft (3m) rear-entry power cord. The L21-30P is the standard 30A 3-phase WYE connector for North American data center and colo infrastructure.
Q: How many outlets does the I10116L have and what type are they?
A: Six locking IEC C19 (U-Lock) receptacles, each rated at 208V. They are divided across three circuits (two receptacles per circuit), color-coded Orange, Green, and Blue for easy circuit identification.
Q: What certifications does the I10116L carry?
A: UL and c-UL Listed to 62368-1, RoHS Compliant, and FCC Part 15 Class A Conformance.

The detail that stands out to me on the I10116L is the three-tier monitoring architecture — aggregate, phase, and per-circuit — combined with ANSI C12.1/IEC 62053-21 1% accuracy at the unit and phase levels. In a 3-phase deployment, phase imbalance is the quiet killer: you can have a perfectly healthy aggregate load reading while one phase is sitting at 90% and another at 40%. The per-phase W, VA, V, A, and PF readouts on this unit give you the visibility to catch that before something trips, not after.
Technical Highlights:
Deployment Considerations:
This unit fits cleanest in a federal or regulated-sector colo deployment where TAA compliance is gated, phase-level load visibility is a facility requirement, and the option to add network monitoring later without a hardware swap preserves budget flexibility across a multi-year buildout.