Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology PTCORD-L1 Locking C19 to L6-20P Power Cord
Overview
The Server Technology PTCORD-L1 is a 10-foot locking power cord that terminates an IEC 60320/C19 connector to an L6-20P twist-lock plug, built for 200-240VAC input at 20A. If you're feeding a rack PDU or server chassis from a 208V/240V twist-lock receptacle and want to rule out accidental disconnects under vibration or a snagged cable, PTCORD-L1 is the connector pair to specify. It's rated 12 AWG and carries cULus listing, which matters when the cord is running load in a commercial data hall or telecom closet where inspectors check for listed components.
Key Features
- Locking IEC 60320/C19 connector: the C19 end locks onto the PDU or server inlet instead of relying on friction fit — in a densely cabled rack where techs are reaching past dozens of cords to service one unit, a locking C19 means you don't accidentally unseat a neighboring server's power feed.
- L6-20P twist-lock plug: the wall or PDU-input end is a NEMA L6-20P twist-lock, so the cord locks into a compatible L6-20R receptacle rather than pulling free — the right call for under-floor or overhead cable runs where tension on the cord is a given, not an edge case.
- 200-240VAC rating: this cord is built for split-phase or three-phase-derived 208V/240V circuits common in commercial electrical distribution, not 120V branch circuits — confirm your upstream receptacle voltage before ordering since this cord won't step down or adapt.
- 20A amperage rating: matches the L6-20P plug's rated capacity, giving headroom for a fully loaded rack PDU pulling steady current without derating concerns on the cord itself.
- 12 AWG conductor gauge: heavier gauge than the 14-16 AWG found on lighter-duty IEC cords, which keeps voltage drop and heat buildup in check when you're running sustained 20A loads across the full 10-foot length.
- 10 ft (3m) length: long enough to route from a wall-mounted or floor-mounted L6-20R receptacle up through a rack's cable channel to a top-of-rack or mid-rack PDU without needing an extension — check your rack elevation and receptacle placement against this length before specifying.
- cULus certification: listed for use in the US and Canada, which is what facility inspectors and AHJs look for when signing off on a data center or telecom room build-out.
Integration & Compatibility
PTCORD-L1 (often searched as PTCORD L1) is a connector-specific cord — it pairs an IEC 60320/C19 female connector with an NEMA L6-20P male twist-lock plug, so compatibility runs both directions: the equipment side needs a C19 inlet (common on rack PDUs, UPS units, and higher-draw servers) and the source side needs an L6-20R twist-lock receptacle. This is a straightforward swap-in for any Server Technology PDU deployment or third-party gear sharing the same C19 inlet standard, and it's worth keeping a spare on hand in any rack where twist-lock power is the house standard — a loose or damaged whip cord is an easy single point of failure to overlook during a rack audit.
Frequently Asked Questions
Q: What voltage is the PTCORD-L1 rated for?
A: 200-240VAC. It is not intended for 120V circuits.
Q: What's the amperage rating on the PTCORD-L1?
A: 20A, matching the L6-20P plug rating.
Q: Is the PTCORD-L1 a locking cord on both ends?
A: The IEC 60320/C19 connector end locks into a compatible C19 inlet, and the L6-20P end is a twist-lock plug designed to secure into an L6-20R receptacle.
Q: What wire gauge does the PTCORD-L1 use?
A: 12 AWG.
Q: Is the PTCORD-L1 safety listed?
A: Yes, it carries cULus certification.
Q: How long is the PTCORD-L1?
A: 10 ft (3m).

I get asked about locking power cords more than almost any other accessory in a rack build-out, and the PTCORD-L1 covers a specific gap: 20A, 200-240VAC service with a locking C19 on the load end and an L6-20P twist-lock on the source end.
Technical Highlights:
- 12 AWG conductors: heavier than what you'll find on standard-duty IEC whips, so voltage drop stays manageable across the full 10 ft run at 20A sustained load.
- 200-240VAC / 20A rating: sized to match the L6-20P plug's own rating — no derating math needed when you're speccing a rack PDU feed.
- cULus listing: the certification an AHJ or facility inspector actually checks for before signing off on a data center or telecom room build.
Deployment Considerations:
- Confirm the source receptacle is genuinely an L6-20R twist-lock before ordering — this cord won't mate with a standard NEMA 5-20 or L5-20 receptacle.
- At 10 ft, measure your actual run from receptacle to PDU inlet first; twist-lock cords aren't the kind of thing you want to extend with an adapter mid-rack.
This is the cord I'd specify for a colo cage or telecom closet standardizing on twist-lock 208V distribution, where the locking C19 keeps a fully-loaded rack PDU from getting knocked loose during routine service work.
Compare with similar
Server Technology Locking Iec 60320/C19 - L6-20P - Ptcord-L1
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology