Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology PTCORD-L6 Locking C19 to 5-20P Power Cord
Overview
The PTCORD-L6 is a 10ft (3m) power whip from Server Technology built to connect rack PDUs and IT equipment with a locking IEC 60320/C19 connector on one end and a 5-20P straight-blade plug on the other. It's rated 20A and built with 12 AWG conductors, targeting data center and server room installs where a cord backing out of an outlet mid-shift is not an acceptable failure mode. PTCORD-L6 (often searched as PTCORD L6) is the locking-C19 variant in Server Technology's cord lineup, distinct from non-locking equivalents in the same family.
Key Features
- Locking IEC 60320/C19 connector: the C19 end locks into a compatible PDU outlet, so vibration, cable weight, or an accidental tug in a packed rack doesn't pull the cord loose and drop power to connected gear.
- 5-20P straight-blade plug: terminates into a standard NEMA 5-20P 20A receptacle, giving you a direct path from wall or rack-mounted 20A circuits without an adapter.
- 20A current rating: matches the higher end of common 120V rack circuits, so this cord can carry more sustained load than a standard 15A whip before you need to worry about derating.
- 12 AWG conductors: heavier gauge than the 14-16 AWG found on lighter-duty cords, which keeps voltage drop and heat down when running at or near the 20A rating over the full 10ft run.
- 10ft (3m) length: enough reach to route from a PDU at the top or bottom of a rack down to a floor receptacle, or between adjacent rack positions, without splicing or an extension.
- cULus approval: listed to UL and CSA safety standards, which is typically a requirement for passing electrical inspection in commercial data center builds.
Integration & Compatibility
Use the PTCORD-L6 as the whip between a rack PDU's locking C19 output and a 20A 5-20R wall or floor receptacle. It pairs naturally with Server Technology rack PDUs and other equipment exposing a locking C19 input. If you're specifying PDU whips for a new rack build, a rack PDU sizing and selection guide is worth reviewing alongside this cord to confirm circuit and connector matching before order. For racks where the branch circuit terminates in a twist-lock rather than a straight-blade receptacle, check the same family for a twist-lock variant instead of forcing this cord with an adapter.
Frequently Asked Questions
Q: What connector does the PTCORD-L6 use on the PDU side?
A: A locking IEC 60320/C19 connector, which mechanically locks into a compatible C19 inlet to resist accidental disconnection.
Q: What's the current rating on the PTCORD-L6?
A: 20A, matching the 5-20P plug end and 12 AWG conductor sizing.
Q: How long is the PTCORD-L6 power cord?
A: 10ft (3m).
Q: Is the PTCORD-L6 safety listed?
A: Yes, it carries cULus approval.
Q: What wire gauge does the PTCORD-L6 use?
A: 12 AWG.

The PTCORD-L6 is a straightforward spec once you know what's on each end: locking C19 into 5-20P, 20A, 12 AWG. I get asked about this cord mostly by people replacing a whip that walked out of its PDU outlet during rack work — the locking C19 is the fix for that specific problem.
Technical Highlights:
- Locking C19 connector: mechanically retains the connection at the PDU end, which matters most in racks with frequent cable moves or dense cable management pulling on the whip.
- 20A / 12 AWG pairing: the conductor gauge is sized to the 20A rating rather than undersized like you'll see on cheaper 15A-rated cords repurposed at 20A — less voltage drop over the 10ft run.
- 10ft length: long enough to route from a top-of-rack PDU down to a floor receptacle in most standard rack heights without needing a second cord or extension.
Deployment Considerations:
- Confirm your branch circuit receptacle is a 5-20R before ordering — this cord's plug end is straight-blade 5-20P, not twist-lock, so it won't seat in a L5-20R twist-lock outlet.
- Minimum order quantities can apply on PDU accessory cords like this one; confirm order quantity before finalizing a rack build-out.
Specify the PTCORD-L6 when you're wiring a rack PDU to a 20A straight-blade circuit and want the PDU-side connection locked down — typical in colocation cages and data center rows where techs are in and out of the rack regularly.
Compare with similar
Server Technology Locking IEC 60320/C19 - 5-20P (20A - PTCORD-L6
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology