Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Lifesafety Power FPO75-B100C4D8PE4M1 75W Industrial Power Supply Module

Overview

The FPO75-B100C4D8PE4M1 is a 75W power module engineered for distributed power supply deployments in access control, door management, and security system installations. It delivers either 6A at 12VDC or 3A at 24VDC from a standard AC input, with an adjustable secondary 5–18V output rated at 4A maximum. This configuration supports mixed-voltage endpoint ecosystems where legacy 12V infrastructure coexists with modern 24V equipment—eliminating the need for separate power rails and reducing panel real estate.

Outputs and Control

Four dedicated relay lock control outputs (fused independently at 3A each) provide failsafe/failsecure switching for door strikes, mag locks, and credential readers. Each relay is selectable for FAI (Fire Alarm Interface) or standard failsafe/failsecure logic, enabling coordinated access denial during emergency events. Eight class 2 power-limited auxiliary outputs (2.5A per output) are bus-selectable, allowing independent distribution to sensors, request-to-exit devices, and supplemental signaling without overloading a single circuit. This granular output architecture simplifies wiring discipline and fault isolation in multi-zone access control systems.

Physical and Environmental Specification

The unit measures 24H × 20W × 4.5D inches with a Mercury back plate and integral door-mount kit. This shallow form factor (4.5 inches deep) fits standard electrical cabinets without requiring extension rails, and the back-plate design permits secure mounting to existing DIN-rail or cabinet doors. The enclosure houses all outputs and fusing, reducing field wiring complexity and inventory management for integrators deploying multiple units across a facility.

Installation Notes

Each relay output and auxiliary output is independently fused—verify amperage load per endpoint before assignment to prevent nuisance trips. Relay outputs support both FAI and standard logic; configure during commissioning based on site fire code requirements. Primary input voltage and secondary 5–18V output are not simultaneous; configure secondary output only when primary 12V/24V rails are unavailable on the endpoint device.

Specifications
Form Factor: Modular power module with Mercury back plate
Input Voltage: AC (standard range)
Output Voltage: 12VDC (6A) or 24VDC (3A); secondary 5–18VDC (4A adjustable)
Max Current: 6A at 12V, 3A at 24V, 4A secondary adjustable
Number of Outputs: 4 relay lock control outputs, 8 auxiliary outputs
Enclosure_Dimensions: 24H × 20W × 4.5D inches
Supervision: FAI (Fire Alarm Interface) capable on relay outputs
Brand: Lifesafety Power
MPN: FPO75-B100C4D8PE4M1
Type: Power Supply
Power: 12V DC
Q&A
Reviews
Have Questions?

Lifesafety Power FPO75-B100C4D8PE4M1 75W power supply 6A/12V

$1,005.00
$660.99

RELATED PRODUCTS

Save $426.01
Lifesafety Power FPO75-B100M8PNLCE2M 75W power supply 6A/12V
Add to Cart The item has been added

Lifesafety Power FPO75-B100M8PNLCE2M

Lifesafety Power FPO75-B100M8PNLCE2M 75W power supply 6A/12V

75-watt managed power supply with an integrated 8-output distribution panel rated at 2.5A per channel

  • 8 independent 2.5A-limited channels protect each camera circuit from single-point faults.
  • Supports 12VDC at 6A or 24VDC at 3A to match existing on-site infrastructure voltage.
  • Managed distribution eliminates per-line fuses, reducing junction-box complexity in the field.
Usually Ships in 2-3 Weeks Free shipping over $499
$1,244.00 $817.99 Save $426.01
The item has been added Add to quote
$1,244.00 $817.99 Save $426.01
Save $426.01 Add to cart Add to quote
Save $409.01
Lifesafety Power FPO75-B100D8M8NLCE2M 75W power supply 6A/12V
Add to Cart The item has been added

Lifesafety Power FPO75-B100D8M8NLCE2M

Lifesafety Power FPO75-B100D8M8NLCE2M 75W power supply 6A/12V

75W managed distribution power supply designed for security installations requiring regulated, independently fused power delivery across multiple

  • Eight individually fused 3A DC outputs prevent a single device fault from taking down other loads.
  • Dual-bus architecture lets you isolate zones across Bus1 and Bus2 without external switching hardware.
  • Configurable 12VDC @ 6A or 24VDC @ 3A output supports mixed IP camera and access control loads.
Usually Ships in 2-3 Weeks Free shipping over $499
$1,193.00 $783.99 Save $409.01
The item has been added Add to quote
$1,193.00 $783.99 Save $409.01
Save $409.01 Add to cart Add to quote
Save $326.01
Lifesafety Power FPO75-B100C4D8E2X 75W power supply 6A/12V or 3A
Add to Cart The item has been added

Lifesafety Power FPO75-B100C4D8E2X

Lifesafety Power FPO75-B100C4D8E2X 75W 6A/12V

75W power supply designed to deliver both primary load power and integrated relay logic control for distributed access control and security device

  • Delivers 6A/12V or 3A/24V primary output plus adjustable 5–18VDC at 4A for legacy devices.
  • Four relay outputs support failsafe, failsecure, or FAI logic—each fused at 3A for circuit protection.
  • Eight auxiliary DC outputs assignable to Bus1 or Bus2 prevent cross-loading across independent control circuits.
Usually Ships in 2-3 Weeks Free shipping over $499
$952.00 $625.99 Save $326.01
The item has been added Add to quote
$952.00 $625.99 Save $326.01
Save $326.01 Add to cart Add to quote
Save $390.01
Lifesafety Power FPO75-B100C8PE4H 75W power supply 6A/12V or 3A
Add to Cart The item has been added

Lifesafety Power FPO75-B100C8PE4H

Lifesafety Power FPO75-B100C8PE4H 75W Power Supply

75W switching power supply with eight independently configurable relay-control outputs designed for distributed access-control and security

  • Eight relay outputs each rated 2.5A with selectable fail-safe, fail-secure, or fail-as-is logic.
  • Single unit powers mixed-voltage loads: 6A@12VDC, 3A@24VDC, and 4A adjustable 5–18VDC.
  • Bussed cable architecture in the E4 enclosure reduces field-wiring labor across multi-cabinet runs.
Usually Ships in 2-3 Weeks Free shipping over $499
$1,138.00 $747.99 Save $390.01
The item has been added Add to quote
$1,138.00 $747.99 Save $390.01
Save $390.01 Add to cart Add to quote
Save $331.01
Lifesafety Power FPO75-B100C8D8PE4M 75W power supply 6A/12V or 3
Add to Cart The item has been added

Lifesafety Power FPO75-B100C8D8PE4M

Lifesafety Power FPO75-B100C8D8PE4M 75W 6A/12V

75W dual-output power supply engineered for access control and perimeter security integration where relay-driven lock control and auxiliary equipment

  • Selectable 12VDC/24VDC primary output eliminates separate modules in mixed-voltage installs.
  • 8 relay outputs—individually fused at 3A—support failsafe, failsecure, or FAI programming.
  • 8 class 2 auxiliary DC outputs (2.5A each) power REX buttons, sirens, and ancillary devices.
Usually Ships in 2-3 Weeks Free shipping over $499
$966.00 $634.99 Save $331.01
The item has been added Add to quote
$966.00 $634.99 Save $331.01
Save $331.01 Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources