Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GXT5-3KL630TF4000 Online UPS and Transformer Distribution Bundle

Overview

The Vertiv GXT5-3KL630TF4000 is a bundled power protection solution pairing the GXT5-3KL630RT2UXL online double-conversion UPS with the TDU-4000RTL630 transformer distribution unit — configured for facilities drawing from a 630V high-voltage building feed and stepping down to standard equipment-level voltages. This combination is relevant for data centers, network equipment rooms, and rackmount UPS deployments where the local power infrastructure does not deliver standard 120V or 208V directly to the load. The GXT5 platform from Vertiv's power protection line uses online double-conversion topology, meaning utility power is continuously converted and re-synthesized — load equipment never runs on raw utility power, and switchover time on outage is zero. This eliminates voltage sags, spikes, and frequency variations before they reach connected equipment. The TDU-4000RTL630 transformer unit in this bundle handles the voltage step-down function, making the pair suitable for markets or building infrastructure where 630V feeds are standard. If your facility already delivers 208V or 120V at the rack, the standalone GXT5 UPS variants are the more direct fit; the transformer component here adds value only where the input voltage mismatch exists.

Key Features

  • Online Double-Conversion Topology: The GXT5 platform continuously conditions power — no transfer time on outage, no pass-through of utility noise or transients to connected loads. Critical for NVRs, servers, and network infrastructure where even a 4ms gap can trigger a reboot.
  • 630V Input Compatibility via TDU-4000RTL630: The transformer distribution unit in this bundle steps down from a 630V feed to standard equipment-level output — enabling deployment in facilities with high-voltage building infrastructure without requiring separate electrical work at the rack level.
  • GXT5 Platform Scalability: The GXT5 family spans 500VA to 3000VA in rackmount form, allowing capacity planning across a range of power protection deployments. Selecting the right VA/W rating for your actual load is the primary sizing decision — oversizing wastes budget; undersizing risks overload shutdowns under full-camera-system or NVR load spikes.
  • 2U Rackmount Form Factor: The RT2UXL designation indicates a 2U rack-optimized chassis — fits standard 19-inch equipment racks alongside the NVRs, switches, and servers it protects. No separate UPS floor footprint required.
  • Vertiv Monitoring Ecosystem: The GXT5 platform supports Vertiv's management software and SNMP-based network management cards, enabling remote monitoring of battery health, load percentage, and runtime estimates from a central management console — a practical requirement for distributed sites managed without on-site staff.

Integration and Compatibility

This bundle is designed for environments where a 630V building feed is the available power source. The TDU-4000RTL630 provides the voltage conversion stage; downstream, the GXT5 UPS delivers conditioned, battery-backed power to rack equipment. Vertiv's GXT5 line integrates with major building management systems and supports optional network management cards for SNMP monitoring. For NVR and surveillance infrastructure deployments, pair UPS capacity planning with your full load calculation — cameras, PoE switches, NVRs, and any edge compute all draw from the same protected circuit. For deployments without a 630V input requirement, evaluate standalone GXT5 units or other capacity points in the Vertiv catalog directly.

Frequently Asked Questions

Q: What does the TDU-4000RTL630 component do in this bundle?

A: The TDU-4000RTL630 is a transformer distribution unit that steps down a 630V input feed to a voltage level compatible with the GXT5 UPS. It is the input-side voltage conversion component in this paired solution — relevant only for facilities where 630V is the available building feed.

Q: What is the UPS topology of the GXT5 platform?

A: The GXT5 uses online double-conversion topology. Utility power is continuously rectified and re-inverted, so the connected load always runs on synthesized, conditioned power. Switchover to battery on a utility outage is zero-transfer-time, eliminating the brief interruption that occurs with line-interactive or standby designs.

Q: Is the GXT5-3KL630TF4000 suitable for a standard 120V or 208V facility?

A: This specific bundle is configured for a 630V input feed via the TDU-4000RTL630 transformer. If your facility already supplies 120V or 208V at the rack, you do not need the transformer component and should evaluate a standalone GXT5 UPS model matched to your load and input voltage.

Q: Can the GXT5 UPS be monitored remotely?

A: The GXT5 platform supports optional network management cards enabling SNMP-based remote monitoring of battery status, load levels, and estimated runtime. This is compatible with Vertiv's Liebert IntelliSlot ecosystem and third-party building management systems.

Q: What rack space does this solution require?

A: The GXT5 RT2UXL chassis occupies 2U in a standard 19-inch rack. The TDU-4000RTL630 transformer unit requires additional rack space — confirm total rack unit requirements against your available rack inventory before ordering.

Jerry Tildsen
Jerry Tildsen

The GXT5-3KL630TF4000 is a purpose-built pairing for one specific deployment scenario: a facility with a 630V high-voltage building feed that needs rack-level double-conversion UPS protection without a separate electrical infrastructure project. The TDU-4000RTL630 handles the step-down; the GXT5 handles the conditioning and battery backup. It is not a general-purpose UPS bundle — if 630V input does not describe your site, this is not the right SKU.

Technical Highlights:

  • Zero-Transfer Topology: Online double-conversion means the GXT5 re-synthesizes output continuously — no transfer gap, no utility noise reaching the load. For NVRs and network infrastructure, this is the only topology worth specifying in critical applications.
  • 630V Input Stage: The TDU-4000RTL630 transformer is the distinguishing component of this bundle. It exists specifically for high-voltage input infrastructure — common in certain international markets and some older North American industrial/commercial buildings.
  • 2U Rack Integration: The RT2UXL chassis fits a standard 19-inch rack. Combined with the transformer unit, plan your rack layout before deployment — confirm U-space availability for both components.

Deployment Considerations:

  • Verify your building feed voltage before ordering. This bundle is configured for 630V input — ordering for a 208V or 120V facility results in an incompatible transformer stage with no straightforward workaround.
  • Load sizing is the most common mistake on GXT5 deployments. Total your connected load (NVRs, PoE switches, compute) at full draw, not idle — UPS runtime drops sharply as load approaches rated capacity.

Right-fit scenario: a network equipment room or surveillance head-end in a building with 630V distribution infrastructure, where the operator needs rackmount double-conversion UPS protection without a separate step-down transformer installation project. Outside that specific input voltage context, evaluate the standalone GXT5 variants instead.

Specifications
Models: Power Rating
Gxt5-500Lvrt2Uxl: 500VA / 500W
Gxt5-500Lvrt2Uxln: 500VA / 500W
Gxt5-750Lvrt2Uxl: 750VA / 750W
Gxt5-750Lvrt2Uxln: 750VA / 750W
Gxt5-1000Lvrt2Uxl: 1000VA / 1000W
Gxt5-1000Lvrt2Uxln: 1000VA / 1000W
Gxt5-1500Lvrt2Uxl: 1500VA /1350W
Gxt5-1500Lvrt2Uxln: 1500VA /1350W
Gxt5-2000Lvrt2Uxl: 2000VA / 1800W
Gxt5-2000Lvrt2Uxln: 2000VA / 1800W
Gxt5-3000Lvrt2Uxl: 3000VA / 2700W
Gxt5-3000Lvrt2Uxln: 3000VA / 2700W
freight: 565.40
Q&A
Reviews

Vertiv GXT5-3KL630TF4000 UPS

$6,465.00
$4,565.99

RELATED PRODUCTS

Save $1,019.01
Vertiv GXT5 2000VA UPS - GXT5-2000LVRT2UXL
Add to Cart The item has been added

Vertiv GXT5-2000LVRT2UXL

Vertiv GXT5 2000VA UPS - GXT5-2000LVRT2UXL

2000VA / 1800W online double-conversion UPS in a compact 2U rack/tower form factor, built for commercial security systems, network closets, and

    In stock · Ships same business day Free shipping over $499
    $3,225.00 $2,205.99 Save $1,019.01
    The item has been added Add to quote
    $3,225.00 $2,205.99 Save $1,019.01
    Save $1,019.01 Add to cart Add to quote
    Save $990.01
    Vertiv GXT5 1500VA UPS - GXT5-1500LVRT2UXLTAAN
    Add to Cart The item has been added

    Vertiv GXT5-1500LVRT2UXLTAAN

    Vertiv GXT5 1500VA UPS - GXT5-1500LVRT2UXLTAAN

    1500VA / 1350W online double-conversion UPS built for IT closets, security control rooms, and rack deployments where power conditioning quality and

      In stock · Ships same business day Free shipping over $499
      $3,152.00 $2,161.99 Save $990.01
      The item has been added Add to quote
      $3,152.00 $2,161.99 Save $990.01
      Save $990.01 Add to cart Add to quote

      System Design, Deployment & Technical Support

      Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

      Fixed scope • Fixed price

      System Design Assistance

      • Get help validating product compatibility
      • Coverage requirements
      • Storage planning and deployment architecture before you buy.
      Request Design Help

      Deployment & Configuration Support

      • Access fixed-scope support for rollout planning
      • User setup guidance
      • Migration and system standardization across single-site or multi-site deployments
      View Support Services

      Guides, Tools & Calculators

      • PoE requirements
      • Storage retention
      • Camera selection and deployment methodology
      Open Technical Resources