Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRIDT6X4LYL 3-Port FiberRunner Spillout Fitting

Overview

The Panduit FRIDT6X4LYL is a 3-port spillout fitting designed specifically for use with the FiberRunner® 6x4 routing system. Where a single 6x4 cable runway needs to branch fiber into three separate 1.5-inch (38mm) diameter split corrugated tubing runs, this fitting handles that transition in a single, purpose-built component — no field fabrication, no improvised splitting. Built from polycarbonate/ABS in signal yellow, the FRIDT6X4LYL is sized to match the 6x4 FiberRunner channel geometry (176.8mm wide × 87.9mm tall × 118.4mm long) and sold individually (MOQ 5, carton of 5).

This fitting is part of Panduit's FiberRunner® cable management line, engineered specifically for fiber routing and management in data centers and telco central offices — environments where bend radius compliance, pathway organization, and future-proof scalability are non-negotiable design requirements.

Key Features

  • 3-Port Split Transition: Routes a single 6x4 FiberRunner pathway into three independent 1.5-inch split corrugated tubing exits. In dense fiber environments, this eliminates the need to overpack a single conduit run or improvise branch exits — each of the three ports gives fibers their own protected, bend-radius-compliant pathway out of the main tray.
  • 6x4 System-Specific Fit: Dimensioned precisely for the FiberRunner 6x4 channel (6.96 in / 176.8mm wide, 3.46 in / 87.9mm tall). Pairing this with a different FiberRunner channel size (4x4, 2x4, etc.) won't produce a flush, gasketed fit — confirm your existing runway dimension before ordering.
  • LSZH Material Compliance: Low Smoke Zero Halogen construction means that in a fire event, combustion products are significantly less toxic and produce less obscuring smoke than standard PVC fittings. In telco central offices and densely populated data hall corridors where personnel may need to evacuate through cable pathways, LSZH is frequently a code or design requirement.
  • Polycarbonate/ABS Construction: The PC/ABS blend gives this fitting the impact resistance of polycarbonate and the processability of ABS — practical for a component that gets handled repeatedly during moves, additions, and changes in a live fiber plant. It won't crack under typical installation torque the way brittle thermoplastics can.
  • Yellow Color Coding: The signal-yellow finish aligns with standard data center color-coding conventions for single-mode fiber pathways. In a multi-tiered cable management system with multiple fiber types and cable categories running in parallel trays, visual differentiation at the fitting level reduces mis-routing during MAC work.
  • RoHS Compliant: Meets the EU Restriction of Hazardous Substances directive — relevant for any deployment serving European facilities or organizations with global procurement standards that require RoHS compliance across the full bill of materials including passive infrastructure.
  • UL Listed to 2024 Optical Fiber Cable Routing Assemblies: UL 2024 listing confirms the fitting has been independently tested for use in optical fiber routing applications. This isn't a self-certification — it's a third-party verified rating that satisfies AHJ requirements in jurisdictions requiring listed components for fiber pathway systems.
  • Telcordia GR-63-CORE Level 3 Compliance: GR-63 is the Network Equipment Building Systems (NEBS) standard covering environmental and physical requirements for telecom infrastructure. Level 3 compliance — the most stringent tier — means this fitting has been tested against seismic zone 4 and extreme environmental conditions. Relevant for any carrier-grade or Tier III/IV data center deployment where NEBS is a procurement requirement.

Integration & Compatibility

The FRIDT6X4LYL is designed exclusively for use with the Panduit FiberRunner 6x4 routing system. It accepts three exits of 1.5-inch split corrugated tubing — confirm tubing diameter compatibility before ordering if you're sourcing tubing from a third party. The fitting installs into an existing 6x4 FiberRunner channel section at any branch-off point where fiber needs to exit the main tray and transition to individual protected runs to equipment, patch panels, or splicing enclosures.

For structured fiber deployments in data center infrastructure, this fitting pairs naturally with FiberRunner straight sections, covers, and reducer fittings to build a complete organized fiber pathway. The yellow colorway is consistent across the FiberRunner LSZH product family, maintaining visual continuity in mixed-fitting installations.

What's in the Box

  • 1x Panduit FRIDT6X4LYL 3-Port Spillout Fitting (sold as single unit; minimum order quantity 5, carton quantity 5)

Frequently Asked Questions

Q: What size FiberRunner channel does the FRIDT6X4LYL fit?

A: The FRIDT6X4LYL is designed specifically for the FiberRunner 6x4 routing system. It measures 6.96 inches (176.8mm) wide and 3.46 inches (87.9mm) tall to match the 6x4 channel profile. It is not compatible with other FiberRunner channel sizes such as 4x4 or 2x4.

Q: What diameter tubing does the FRIDT6X4LYL connect to?

A: Each of the three ports on the FRIDT6X4LYL routes cable into 1.5-inch (approximately 38mm) diameter split corrugated tubing. Confirm your tubing inner diameter matches before sourcing tubing separately.

Q: Is the FRIDT6X4LYL LSZH rated?

A: Yes. The FRIDT6X4LYL carries an LSZH (Low Smoke Zero Halogen) designation, making it suitable for installations where local codes or design standards require reduced toxic smoke output in fire conditions — common in telco central offices and occupied data hall environments.

Q: Does the FRIDT6X4LYL meet Telcordia GR-63-CORE requirements?

A: Yes. The FRIDT6X4LYL is compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3 — the most stringent NEBS environmental tier. This makes it suitable for carrier-grade and NEBS-required telecom deployments.

Q: Is the FRIDT6X4LYL UL Listed?

A: Yes. It is UL Listed to UL 2024 for Optical Fiber Cable Routing Assemblies, providing third-party verified compliance for fiber pathway installations where listed components are required by the authority having jurisdiction.

Q: What is the minimum order quantity for the FRIDT6X4LYL?

A: The FRIDT6X4LYL has a minimum order quantity (MOQ) of 5 units and is packaged in cartons of 5. It is priced and sold as a single unit (package quantity 1), so ordering 5 fulfills one carton.

Marty Allison
Marty Allison

The FRIDT6X4LYL is one of those fittings that earns its place in a data center BOM the moment you're staring at a 6x4 FiberRunner trunk that needs to fan out to three separate equipment rows without dropping bend radius compliance. The three 1.5-inch corrugated tubing ports are the key spec here — they give you three independently protected fiber exits at a single branch point, which is considerably cleaner than zip-tying loose bundles over the edge of an open tray.

Technical Highlights:

  • Telcordia GR-63-CORE Level 3: Level 3 is the top NEBS tier — covers seismic zone 4 and the full environmental battery. If your customer's procurement checklist includes NEBS Level 3, this fitting clears it without a waiver or equivalency argument.
  • LSZH + UL 2024: The combination of LSZH material and UL 2024 listing closes two separate compliance boxes in one part number. LSZH satisfies smoke/toxicity requirements; UL 2024 satisfies the AHJ's demand for listed fiber pathway components. Sourcing a fitting that covers both is more efficient than chasing separate compliance documentation.
  • 6.96 × 3.46 in Profile: These aren't nominal dimensions — the 176.8mm width and 87.9mm height are the exact fit geometry for the 6x4 FiberRunner channel. Ordering the wrong fitting size (e.g., a 4x4 spillout) is a common field error; confirm the tray label before spec'ing this into a project.

Deployment Considerations:

  • The three exit ports are designed for 1.5-inch split corrugated tubing specifically — not conduit, not innerduct. If your fiber plant uses a different tubing standard at the equipment end, verify the corrugated tubing OD/ID match before committing to this fitting in your design.
  • MOQ is 5 units — budget accordingly on small projects. A single-cabinet installation with two or three branch points may consume a full carton, so the MOQ is rarely a practical obstacle in a real data center build, but it matters for sparing stock on small refreshes.

This fitting is the right call for carrier hotel builds and Tier III/IV data centers where the combination of NEBS Level 3 seismic compliance, LSZH, and UL 2024 listing are all contract requirements — not optional features. In that spec environment, the FRIDT6X4LYL handles branch transitions without triggering a compliance review.

Specifications
Sub Brand: FiberRunner®
Application: Data Centers and Telco Central Offices
Color: Yellow
Material: Polycarbonate/ABS
Height In: 3.46
Height Mm: 87.9
Width In: 6.96
Width Mm: 176.8
Product Type: 3-Port Spillout
Carton Qty: 5
Package Qty: 1
Standards: RoHS Compliant, UL Listed to 2024 Optical Fiber Cable Routing Assemblies Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3
Upc: 61305676408
Cable Category: wire-routing-management-protection
Type: 3-Port Spillout
Q&A
Reviews
Have Questions?

Panduit Fitting 3-PORT Spillout TO 1.5IN PK1MOQ5

$55.72
$36.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources