Vertiv EX 42U 600 1200 White Shock Crate - GL42UEX-60120W-MS-SC
42U, 600mm wide, 1200mm deep rack enclosure finished in white, designed for secure and protected deployment of IT and network infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv GL42UEX-60120W-MM-SC is a 42U, 600mm wide by 1200mm deep shock-rated rack enclosure finished in white — built for deployments where standard cabinets aren't sufficient. Shock-rated construction means this enclosure can survive the physical stresses of transport, staging, and installation in environments prone to vibration or seismic activity: manufacturing floors, broadcast facilities, government infrastructure sites, and military or ruggedized edge deployments. At 42U with a 1200mm depth, it accommodates full-depth servers, high-density storage arrays, and the cable management needed to keep a dense cabinet serviceable. The GL42UEX-60120W-MM-SC (often searched as GL42UEX 60120W MM SC) belongs to Vertiv's Geist lineup of purpose-built rack solutions — a line worth evaluating any time your deployment has requirements beyond a standard open-frame or light-duty enclosure.
The GL42UEX-60120W-MM-SC is a standard 19-inch EIA-310 rack enclosure. It accepts any rackmount equipment built to that standard: servers, network switches, patch panels, UPS units, KVM consoles, and cable management accessories. At 1200mm depth it accommodates full-depth enterprise hardware from major server vendors. Pair this cabinet with a rack-mount UPS or PDU appropriately sized to the load; Vertiv's own Geist and Liebert power distribution lines are designed to the same rack dimensions and mount without adapter hardware. For data center row planning, the 600mm width integrates with standard server rack and cabinet aisle configurations. If your deployment requires cable pathway coordination above or below the rack, verify that overhead trays or under-floor channels match the 600mm footprint. For network-dense builds, consult a managed switch selection that fits within the remaining U-space after compute gear is installed.
Q: What does shock-rated mean on the GL42UEX-60120W-MM-SC, and when do I need it?
A: Shock-rated means the enclosure is structurally validated to withstand defined mechanical shock loads — covering scenarios like configured shipping, floor vibration in industrial environments, and seismic compliance requirements. If your deployment site is in a seismic zone, on a raised floor near heavy HVAC, or requires certified transport of a populated rack, this rating is relevant. For a standard office or data center row with no seismic or vibration exposure, a non-shock-rated enclosure is typically sufficient and may be lower cost.
Q: What rack equipment fits in the GL42UEX-60120W-MM-SC?
A: This is a standard 19-inch EIA-310 enclosure. It accepts any rackmount equipment built to that standard, including full-depth servers, storage arrays, top-of-rack switches, patch panels, UPS units, and PDUs. The 1200mm depth accommodates full-depth 1U and 2U enterprise server chassis without forcing rear cable bends.
Q: Why does the color (white) matter for the GL42UEX-60120W-MM-SC?
A: White enclosures are specified in broadcast studios, medical environments, cleanrooms, and facilities with aesthetic or compliance-driven color standards. It is a functional procurement spec in those contexts. If your facility has no color requirement, equivalent configurations in standard grey or black may be available and are interchangeable in terms of structural performance.
Q: Is the GL42UEX-60120W-MM-SC suitable for a high-density AI server deployment?
A: At 42U with 1200mm depth, yes — it provides the vertical space and depth clearance for full-depth GPU servers and the rear-mounted power and cable management they require. Verify the rack's rated static load capacity against your total equipment weight before finalizing the build, and ensure your PDU selection matches the power draw of the installed equipment.
Q: How does the 1200mm depth compare to shallower rack options?
A: The 1200mm depth is designed for full-depth enterprise gear (servers typically running 900–1000mm) plus rear PDU and cable management space. Shallower enclosures (800–1000mm) may force cable compression at the rear, complicate servicing, and exclude certain full-depth chassis. If all your equipment is half-depth or less, a shallower cabinet reduces floor footprint; if you're mixing full-depth servers with structured rear cabling, 1200mm is the practical choice.

The GL42UEX-60120W-MM-SC is the model to specify when you have two concurrent requirements that most standard enclosures don't satisfy together: shock-rated structural validation and a 42U, 1200mm-deep footprint in white. I see this combination most often in broadcast infrastructure and government edge deployments where the cabinet travels configured, the facility has a color standard, and the installed equipment is full-depth.
Technical Highlights:
Deployment Considerations:
This enclosure is the right call for a broadcast operations center or government facility edge node where the rack ships pre-populated, white is a facility requirement, and seismic or transport shock documentation is part of the acceptance checklist.