Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: ELK-319PB1
UPC: 762158190063
Availability: Usually Ships in 2-3 Weeks
Write a Review 16% OFF

ELK Products ELK-319PB1 3VDC Auxiliary Power Accessory

3VDC auxiliary power module for ELK security system access control

$93.36 $77.99 SAVE $15

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

ELK Products ELK-319PB1 3VDC Auxiliary Power Accessory

$93.36
$77.99

Overview

SKU: ELK-319PB1
UPC: 762158190063
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

ELK Products ELK-319PB1 3VDC Auxiliary Power Accessory

The ELK-319PB1 is a low-voltage auxiliary power component designed to integrate auxiliary devices within ELK Products security systems. Operating at 3VDC, this accessory supplies power and signal coordination for access control and alarm management installations where auxiliary devices require stable, regulated low-voltage support. The 3VDC specification means you're working with extremely low power draw — this accessory is meant to feed simple signal circuits, not high-current loads — a critical distinction when planning your auxiliary device architecture.

Key Features

  • 3VDC Operating Voltage: Low-voltage DC supply eliminates the need for separate power conditioning or transformer modules in most retrofit and new-build scenarios. Verify your control panel's power supply capacity before assigning multiple auxiliary loads.
  • ELK System Integration: Designed for ELK security control environments where auxiliary component coordination is essential. This accessory works within the ELK ecosystem; cross-brand integration is not supported without additional interface modules.
  • Access Control and Alarm Support: Typical deployment scenarios include powering relay modules, signal conditioners, or indicator circuits in access control panels and alarm management systems. The 3VDC output is suitable for low-draw auxiliary circuits — not for solenoid locks, high-current door strikes, or powered devices without a dedicated power supply.
  • Retrofit and New-Build Compatible: Works in both retrofit installations (where space and power budgets are tight) and new-build deployments. Verify compatibility with your specific ELK control panel model before ordering — not all panels support external auxiliary power modules.

Integration & Compatibility

Before deploying the ELK-319PB1, confirm that your ELK security control panel includes an auxiliary power port or connector rated for 3VDC input. Installation integrators should verify compatibility with the specific control panel model and confirm power supply availability within the 3VDC specification range. This component is not compatible with non-ELK security systems without additional interface hardware. For retrofit projects, measure available panel space and power budget to ensure the accessory can be mounted and wired without strain on existing circuits.

Deployment Considerations

The ELK-319PB1 is purpose-built for low-power auxiliary signal circuits. Do not attempt to use this accessory to power high-current devices such as electric strikes, solenoid locks, or relay coils rated above 500 mA — that will cause voltage sag and potential system instability. If your deployment requires higher auxiliary power, plan for a separate 12VDC or 24VDC power module instead. Always consult the ELK control panel manual to identify the correct auxiliary connector and confirm the power budget available for external devices. In alarm system designs, auxiliary power is often used for indicator lights, signal-conditioning modules, or low-draw relay controllers — confirm your device's power consumption before assignment.

Ted Perry
Ted Perry
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

The ELK-319PB1 is a straightforward low-voltage accessory that fills a real niche: you have an ELK security panel with auxiliary circuitry that needs stable 3VDC, and the internal supply won't stretch to cover another device. That's your use case. The spec sheet is sparse because this is a simple component — no moving parts, no configuration, no analytics — but that simplicity is also its limitation.

Technical Highlights:

  • 3VDC Supply Specification: Rock-solid low-voltage regulation is critical in alarm and access control environments. If you're powering indicator LEDs, pulse counters, or signal conditioning circuits, voltage stability prevents false alarms and nuisance trips. Low-voltage circuits are inherently more noise-resistant than higher-voltage DC supplies.
  • ELK-Specific Connector: This accessory will only work if your ELK control panel has the correct auxiliary port. Verify the panel model against the ELK system architecture before deployment.
  • Retrofit-Ready Form Factor: Designed to fit within existing ELK panel enclosures without requiring additional panel modifications or external housings.

Deployment Considerations:

  • This is not a general-purpose 3VDC supply. It's engineered for ELK auxiliary device integration. Attempting to repurpose it for non-ELK systems or high-current applications will void any compatibility claim.
  • Power budget is tight: confirm that your control panel's internal power supply can handle the additional auxiliary load. Panel datasheets often list maximum auxiliary power capacity. Exceed that limit and you risk voltage sag across the entire panel.
  • In multi-device access control layouts, each auxiliary circuit draws current from the same supply. If you're adding multiple signal modules, calculate total current draw before assigning them all to the ELK-319PB1.

Size this accessory for small-scale auxiliary circuits in ELK installations — indicator lights, signal conditioning, low-draw relay circuits. If you're building a larger access control system with multiple door strikes and readers, you'll likely need a dedicated 12VDC or 24VDC auxiliary power module, not a 3VDC accessory. Know the boundary of your application, verify panel compatibility, and you'll have a solid, stable auxiliary power solution.

Frequently Asked Questions

Q: Is the ELK-319PB1 compatible with all ELK security panels?

A: No. The ELK-319PB1 is designed for ELK security systems with an auxiliary power port. Verify your specific control panel model supports 3VDC auxiliary input before purchasing. Consult the panel manual or contact ELK technical support to confirm connector type and power budget.

Q: What devices can I power with the ELK-319PB1?

A: The 3VDC output is suitable for low-draw auxiliary circuits such as indicator LEDs, signal conditioning modules, and pulse counters. Do not use it for solenoid locks, electric strikes, or high-current relay coils — those require dedicated 12VDC or 24VDC power supplies. Total current draw across all auxiliary circuits must remain within your control panel's auxiliary power budget.

Q: Can I use the ELK-319PB1 with non-ELK security systems?

A: No. This accessory is designed exclusively for ELK security control environments. Integration with competing systems requires additional interface modules and is not supported by the manufacturer.

Q: Does the ELK-319PB1 require any configuration or programming?

A: No configuration is required. The accessory is a passive power component. Install it into the appropriate auxiliary port on your ELK control panel, wire your auxiliary devices to the output terminals, and verify voltage at the load terminals with a multimeter before full deployment.

Q: What's the maximum current draw the ELK-319PB1 can supply?

A: The 3VDC output is designed for low-power auxiliary circuits. Consult the ELK-319PB1 datasheet and your control panel manual for specific current ratings. Exceeding the panel's auxiliary power budget will cause voltage sag and potential system instability.

Specifications
Product Type: Security Accessory
Voltage: 3VDC
Battery Life: One (1) CR2450 3VDC lithium coin-cell
Operating Temperature: 32 to 120°F (0 to 49°C)
Dimensions: 3.0” L x .2.0” W x 0.7” D
Package Contents: hardware for 3 mounting options: Belt Clip, Wall Mount,
Mount Type: Wall
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

ELK Products ELK-319HRR 3VDC security accessory front view with connector ports
Add to Cart The item has been added

ELK Products

SKU: ELK-319HRR

ELK Products ELK-319HRR Security Accessory 3VDC

3VDC auxiliary I/O component for ELK security control systems

  • 3VDC ceiling-mount wireless sensor for ELK 319 panels
  • One 3VDC lithium battery powers years of low-draw standby
  • Compact 2.29 in diameter housing for low-profile ceiling install
$93.36 $80.99 Save $12.37
The item has been added
Free shipping over $499
$93.36 $80.99 Save $12.37
Add to cart Add to quote
ELK Products ELK-150RT ELK Security Accessory (view 2)
Add to Cart The item has been added

ELK Products

SKU: ELK-150RT

ELK Products ELK-150RT ELK Security Accessory

8VDC security accessory for ELK control system integration

  • Power supply for ELK M1 control boards and access control loads
  • 1.2A output at 13.8VDC for door strikes, keypads, and aux devices
  • 5 x 5 x 4 in wall-mount housing for low-profile panel placement
$93.36 $82.99 Save $10.37
The item has been added
Free shipping over $499
$93.36 $82.99 Save $10.37
Add to cart Add to quote
ELK Products ELK-1RT ELK Security Accessory (view 2)
Add to Cart The item has been added

ELK Products

SKU: ELK-1RT

ELK Products ELK-1RT ELK Security Accessory

Wall-mount security accessory for ELK system integration

  • Audio accessory for ELK M1 control boards in 500-7000 Hz range
  • Compact 5 x 5 x 4 in wall-mount housing for in-enclosure install
  • Ships ready for direct integration with ELK M1 panel architecture
$74.57 $65.99 Save $8.58
The item has been added
Free shipping over $499
$74.57 $65.99 Save $8.58
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources