Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL720E-2936-W-SQM6MS 37U White Mesh Server Rack Enclosure

Overview

The Vertiv GL720E-2936-W-SQM6MS is a 37U rack enclosure sized at 29 inches wide by 36 inches deep in Vertiv's Winter White finish — a purpose-built cabinet for IT environments where airflow management, equipment accessibility, and a clean aesthetic all matter. This is the GL720E line's mid-depth configuration: deep enough to seat standard 1U servers, patch panels, and AV gear without forcing cable management compromises, but not oversized for deployments where floor space is at a premium. If you're fitting out a structured cabling room, a network closet, or a secondary compute row in a data center, the GL720E-2936-W-SQM6MS (often searched as GL720E 2936 W SQM6MS) hits a practical middle ground in the GL720E family's range of height and depth options.

Browse the full Vertiv rack and power catalog to compare enclosures across height and width configurations.

Key Features

  • 37U Usable Height: 37U gives you room to deploy a meaningful mix of active equipment — switches, patch panels, UPS units, and servers — without stacking into a full 42U footprint. In a network closet or IDF, 37U often covers the full buildout without wasting rack space on empty units.
  • 29-Inch Width: The 29-inch external width fits standard 19-inch EIA rack equipment with room for proper side-channel cable routing. If your floorplan or aisle width is constrained, confirm your clearance against the 29-inch external dimension before ordering — the GL720E family also ships in 24-inch-wide configurations for tighter spaces.
  • 36-Inch Depth: At 36 inches, this enclosure accommodates mid-depth servers and most 1U–2U networking gear without forcing rear cable bundling into the chassis. For equipment with extended rear I/O (high-density patch panels, deep UPS units), 36 inches is the practical minimum to keep airflow lanes open behind active equipment.
  • Mesh Front and Rear Doors: Both front and rear doors ship with a mesh panel — not solid steel, not perforated plate, but open mesh. That matters: mesh maximizes passive airflow through the enclosure's front-to-rear thermal path without requiring additional blanking panels or active hot-aisle containment at lower equipment densities. If your environment runs CRAC or precision cooling, mesh doors do not impede those airflow designs either.
  • Winter White Finish: The Winter White color is a deliberate choice for office-adjacent deployments — boardrooms, reception areas, healthcare nursing stations, and corporate IDF rooms where a black industrial cabinet would look out of place. The finish is consistent across the GL720E-2936-W-SQM6MS frame and doors; verify against your environment's lighting before finalizing if color matching is critical.
  • M6 Square-Hole Mounting Rails: The 3/8-inch square-hole pattern with M6 threading is the current standard for rack-mount equipment. You won't need adapter kits or cage nuts for equipment shipped with M6 screws, and virtually every enterprise-grade networking and server vendor ships M6-compatible rails. The #10-32 designation confirms compatibility with older or mixed-generation hardware that still ships with #10-32 fasteners.

Integration and Compatibility

The GL720E-2936-W-SQM6MS accepts standard 19-inch EIA-310 rack equipment across all 37U positions. The M6 square-hole rail system is compatible with mounting kits from major vendors including Cisco, HPE, Dell, APC, and Vertiv's own PDU and UPS lines. For deployments pairing this enclosure with structured cabling infrastructure, it fits naturally alongside structured cabling panels and cable management accessories designed for 19-inch rails.

When planning power distribution inside this enclosure, match your rack PDU selection to the 36-inch depth — zero-U vertical PDUs mount in the side channels and leave all 37U positions free for active equipment. Blanking panels are recommended for any open 1U positions to maintain front-to-rear airflow discipline across the mesh doors.

The enclosure is part of Vertiv's GL720E product family, which spans multiple height (13U, 24U, 31U, 37U, 44U), width (24-inch and 29-inch), and depth (32-inch and 36-inch) combinations, as well as color (Black and Winter White) and door style (Mesh Front/Rear, Plexi Front/Solid Rear) options. If this exact configuration doesn't fit your deployment, cross-reference the family matrix against your height, depth, and airflow requirements before switching models. For help sizing your enclosure alongside network switches and active equipment, pre-sales engineering support is available.

Frequently Asked Questions

Q: What mounting hole standard does the GL720E-2936-W-SQM6MS use?

A: The GL720E-2936-W-SQM6MS ships with 3/8-inch square-hole M6 mounting rails, the current EIA standard for enterprise rack equipment. It also accommodates #10-32 hardware for legacy or mixed-generation gear. No cage nut adapters are required for M6-native equipment.

Q: What are the exact external dimensions of the GL720E-2936-W-SQM6MS?

A: The enclosure is 29 inches wide and 36 inches deep. It is a 37U unit; confirm total height in inches with Vertiv's product documentation, as rack unit-to-inch conversions vary by frame design and leveling foot configuration.

Q: Does this rack ship with mesh doors on both the front and rear?

A: Yes. The GL720E-2936-W-SQM6MS includes mesh doors on both the front and rear. The GL720E family also offers a Plexi front / solid rear door combination on alternate SKUs — confirm the door suffix when ordering if airflow or physical security requirements differ.

Q: Is the Winter White finish available in other heights or depths in the GL720E family?

A: Yes. The GL720E line spans 13U, 24U, 31U, 37U, and 44U heights, and is available in both 24-inch and 29-inch widths and 32-inch and 36-inch depths. Winter White is a color option across this matrix; cross-reference the specific SKU suffix to confirm the combination you need.

Q: Can this enclosure be used with Vertiv PDUs and UPS equipment?

A: The standard 19-inch EIA-310 rail system and M6 square-hole mounting are fully compatible with Vertiv's own PDU and UPS product lines, which are engineered to the same rail standard. Verify the physical depth of your UPS unit against the 36-inch enclosure depth before ordering high-capacity units with extended rear chassis.

Q: Are additional door style options available for this rack configuration?

A: The GL720E family offers both Mesh Front/Rear and Plexi Front/Solid Rear door configurations. The GL720E-2936-W-SQM6MS specifically ships with the mesh front and mesh rear combination. If you require a solid rear door for physical security or a plexi front for equipment visibility without opening the cabinet, a different SKU in the GL720E family covers that configuration.

Marty Allison
Marty Allison

I spec the GL720E-2936-W-SQM6MS regularly for office-integrated IDF rooms and secondary network closets where the standard black cabinet creates a facilities conflict. The 29-inch width and 36-inch depth hit the sweet spot for mid-density deployments — you get full server depth clearance without the footprint penalty of a 42-inch-deep data center cabinet, and the mesh front-to-rear door design keeps passive airflow viable even at moderate equipment densities without blanking-panel gymnastics.

Technical Highlights:

  • 37U Height: Enough vertical space to run a complete IDF stack — core switch, patch panels, fiber enclosure, UPS, and a spare PDU — without stacking into a taller footprint that hits ceiling clearance limits in retrofit spaces.
  • Mesh Front and Rear Doors: Open mesh on both faces means you're not fighting the enclosure's own airflow restriction. For environments running perimeter cooling rather than in-row CRAC, this is the right door selection — the enclosure doesn't become the thermal bottleneck.
  • M6 Square-Hole Rails: Every major vendor ships M6-native rail kits. The #10-32 compatibility means you're not buying adapter hardware for that one legacy switch or KVM that hasn't been refreshed yet.

Deployment Considerations:

  • The Winter White finish reads well in office-adjacent installs, but verify under your specific lighting before committing to a multi-cabinet row — color perception shifts noticeably between cool LED and warm ambient environments.
  • At 36 inches of usable depth, budget 2–3 inches at the rear for cable routing and PDU mounting if you're running zero-U vertical power strips. Tight rear clearance on a fully loaded 37U cabinet is the most common field complaint on this depth class.

This enclosure is the right call for a corporate IDF, a healthcare data closet, or any environment where the rack lives in a visible or semi-public space and the standard industrial black finish is a non-starter. It's not a high-density data center cabinet — don't spec it for blade chassis or high-kW compute rows where you need active rear-door cooling and 48-inch depth.

Specifications
Mount Type: Rack
Height: 44U37U31U24U13U
Width: 24"29"
Depth: 32"36"
Color: BlackWinter White
Mounting: #10-323/8" sq. (M6)Clear
Doors: Mesh Front/RearPlexi Front/PV Solid Rear
freight: 574.62
Q&A
Reviews

Vertiv GL720E-2936-W-SQM6MS

$4,854.00
$3,454.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources