Panduit UTP6AX11MGY Category 6A Patch Cord
N 11-meter (36.1 ft) Category 6A UTP patch cord designed for high-speed data networks
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit PUO6AS04BL-G-S is a Category 6A, 4-pair, 23AWG unshielded twisted-pair (UTP) bulk cable rated for 500 MHz bandwidth and 10 Gbps data transmission — designed for structured cabling deployments in data centers, telecommunications rooms, and enterprise network backbones. This 1000-foot pull-box format is the standard purchasing unit for horizontal cabling runs during new construction or large-scale infrastructure refresh projects. Panduit's Panduit structured cabling line is purpose-built for permanent link installations where performance headroom and standards compliance are non-negotiable. The PUO6AS04BL-G-S (often searched as PUO6AS04BL G S) ships factory-new with no grey-market, no parallel imports.
The PUO6AS04BL-G-S terminates with any standard Category 6A-rated keystone jack, patch panel, or field-terminated connector — including Panduit's own Mini-Com and NetKey modular systems. It is compatible with Cat6A patch panels and consolidation point connectors that conform to TIA-568-C.2 component requirements. For permanent link certification, pair with a Category 6A-rated patch cord (typically 5 meters or less at the patch panel and work area) to stay within the 100-meter channel specification.
This cable supports IEEE 802.3bt PoE++ delivery, which requires all four pairs to carry current — verify that downstream devices and patch panels are four-pair power compliant before specifying single-pair or legacy components in the channel. In high-density horizontal cable trays exceeding 24 cables bundled together, derate the channel per TIA-568-C.2 Annex E to account for thermal rise from PoE loads — the 500 MHz bandwidth overhead provides meaningful headroom in these scenarios.
Q: Is the PUO6AS04BL-G-S suitable for 10GBase-T over a full 100-meter run?
A: Yes. The cable is rated Category 6A at 500 MHz with a 10 Gbps data rate, which meets the TIA-568-C.2 channel requirements for 10GBase-T at up to 100 meters when paired with Category 6A-rated connectors and patch cords. The channel must be properly certified to confirm compliance for each installed link.
Q: Does this cable support PoE++ (802.3bt) four-pair power delivery?
A: The 4-pair, 23AWG construction is designed to support all-pairs PoE delivery as required by 802.3bt. Consult TIA-568-C.2 Annex E guidelines for bundle derating when high-wattage PoE devices are deployed across dense cable trays.
Q: What standards does the PUO6AS04BL-G-S meet?
A: The cable is listed as meeting TIA-568-C.2 (North American Category 6A), ISO/IEC 11801 (international Category 6A), and is UL Listed. These are the primary compliance references for enterprise horizontal cabling certification.
Q: What is the bandwidth rating for this cable?
A: 500 MHz — the standard for Category 6A. This is double the 250 MHz rating of Category 6, providing meaningful margin against alien crosstalk and insertion loss, particularly in bundled or high-temperature conduit runs.
Q: Can the PUO6AS04BL-G-S be used in a plenum air-handling space?
A: UL Listed status confirms independent fire and safety testing, but plenum versus riser suitability depends on the specific jacket rating marked on the cable. Verify the CMP (plenum) or CMR (riser) designation on the cable jacket and product label before installing in plenum spaces, as NEC Article 800 requires the correct jacket classification for the installation environment.
Q: How many runs does a 1000-foot box typically cover?
A: At a typical average horizontal run length of 50 feet (including slack at both ends), one 1000-foot pull box covers approximately 15–20 drops. For longer runs or buildings with larger floor plates, calculate actual run averages from your cable schedule before ordering to avoid mid-project shortfalls.

The spec that gets overlooked on the PUO6AS04BL-G-S is the 23AWG conductor gauge — most integrators focus on the 500 MHz bandwidth headline and miss that the heavier gauge is what actually makes this cable compliant for 10GBase-T bundled runs. In a high-density cable tray carrying 802.3bt PoE loads, thinner 24AWG Cat6A can exceed TIA thermal thresholds before you hit the alien crosstalk limits, and that's where field certification failures show up months after punch-list close.
Technical Highlights:
Deployment Considerations:
This cable is the right specification for a data center horizontal run or telecommunications room-to-floor-distribution project where 10GBase-T channel certification is a contract deliverable and PoE++ endpoint density is expected to grow — the 500 MHz headroom and 23AWG construction give the channel durable margin against both thermal and signal degradation over the installation's service life.