Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Vertiv CPQ-1072333-01 11kW Wall-Mount Precision Cooling Unit
Overview
The Vertiv CPQ-1072333-01 is an 11kW wall-mount precision cooling unit designed for IT and telecommunications environments where targeted thermal management is required. Operating on single-phase 208/230V power at 50 or 60Hz, this Coolphase Wall unit delivers a defined cooling output in a wall-mounted form factor — making it a practical fit for edge deployments, small data rooms, or supplemental cooling in larger facilities where overhead or floor space is constrained. CE and UL certifications confirm the unit meets both European and North American safety standards, supporting deployments on either side of the Atlantic without requiring a different model. CPQ-1072333-01 (often searched as CPQ 1072333 01) is sourced factory-new.
Key Features
- 11kW Cooling Capacity: delivers meaningful thermal load removal for a small-to-mid server room or a concentrated edge rack environment — enough headroom to handle a densely populated 2–4 rack cluster without requiring floor-standing CRAC units.
- 208/230V Single-Phase Input: compatible with standard single-phase branch circuits found in commercial buildings and edge locations. No three-phase infrastructure required, which significantly lowers installation complexity in retrofit scenarios.
- 50/60Hz Dual-Frequency Operation: a single SKU covers both North American 60Hz grids and international 50Hz installations, reducing procurement complexity for multi-site or globally distributed deployments.
- CE and UL Certifications: CE marking satisfies EU regulatory requirements for electrical safety and EMC; UL listing meets North American standards. Both are typically required for data center equipment procurement in enterprise and government projects.
- Wall-Mount Form Factor: keeps floor space available for rack equipment and simplifies airflow planning in smaller rooms where raised-floor cooling is not present.
Integration and Compatibility
The CPQ-1072333-01 is positioned for environments already operating on single-phase 208V or 230V distribution — common in edge sites, branch offices, and co-location spaces with limited power infrastructure. Confirm local electrical capacity and circuit breaker sizing before installation; at 11kW output, upstream electrical provisioning is the primary site-readiness factor. Consult Vertiv engineering documentation for refrigerant type, airflow direction, condensate management, and clearance requirements before finalizing placement.
Frequently Asked Questions
Q: What voltage does the Vertiv CPQ-1072333-01 operate on?
A: The CPQ-1072333-01 is rated for 208/230V single-phase operation at 50 or 60Hz, covering both North American and international grid standards.
Q: What is the cooling capacity of the CPQ-1072333-01?
A: The unit delivers 11kW of cooling output.
Q: What certifications does the CPQ-1072333-01 carry?
A: The CPQ-1072333-01 is CE and UL listed, satisfying both European and North American electrical safety requirements.
Q: Is the CPQ-1072333-01 suitable for outdoor installation?
A: Available evidence does not confirm outdoor-rated enclosure or IP ratings for this unit. Consult Vertiv product documentation to verify environmental suitability before specifying for outdoor or harsh-environment locations.
Q: What form factor does the CPQ-1072333-01 use?
A: It is a wall-mount unit, part of the Vertiv Coolphase Wall product line.

The CPQ-1072333-01 lands in a specific niche: 11kW of wall-delivered cooling on a single-phase 208/230V circuit. That combination matters when you're deploying into a branch office or edge location where three-phase power isn't available and floor space can't be allocated to a traditional CRAC unit. It's not a data-center-scale solution — it's a targeted edge thermal answer.
Technical Highlights:
- 11kW Output: sufficient for a concentrated edge rack cluster; size the deployment accordingly — this is supplemental or primary cooling for a small room, not a large multi-row data hall.
- 208/230V Single-Phase: installers working in commercial tenant spaces will appreciate that standard single-phase branch circuits are all that's required — no panel upgrades for three-phase in most retrofit scenarios.
- CE + UL Dual Certification: procurement teams working across North American and European sites can spec a single SKU without managing two separate regional models or compliance dossiers.
Deployment Considerations:
- At 11kW, confirm upstream circuit capacity and breaker sizing before installation — this is the most common site-readiness gap on wall-mount unit deployments.
- Available public evidence does not include airflow direction, refrigerant specification, or condensate drain requirements — pull the Vertiv Coolphase Wall installation manual before finalizing mounting location and clearances.
The CPQ-1072333-01 is a practical spec for edge data rooms, telecommunications closets, or small server rooms in commercial buildings where single-phase power is the reality and floor space is constrained. It is not the right pick for a high-density data hall or any environment requiring three-phase power infrastructure.
Vertiv Coolphase 11KW - CPQ-1072333-01
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology