Panduit UTP6AX13MBU Cat 6A 13m Patch Cord
13-meter (42.7 ft) Cat 6A Unshielded Twisted Pair (UTP) patch cord designed for high-speed data transmission and Power over Ethernet (PoE)
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit UTP6AX13MGY delivers 13 meters (42.7 feet) of certified 10GBASE-T connectivity for cross-rack runs, equipment-room distribution, and server-to-switch links in high-density data centers and network closets. Built on Panduit's TX6A platform with 24 AWG solid-conductor U/UTP cable, this patch cord combines the alien-crosstalk mitigation of foil-tape shielding with the cost efficiency of unshielded construction. Pre-installed RapidID barcodes enable one-scan port documentation, eliminating manual labeling errors during moves, adds, and changes. The tangle-free latch design prevents snags in crowded pathways and ensures fast, positive release under cable-management strain.
The UTP6AX13MGY's solid-conductor design addresses a critical trade-off in permanent versus temporary cabling. Stranded patch cords offer flexibility for desktop moves but suffer higher insertion loss and return loss at 500 MHz, limiting headroom for alien crosstalk in bundle scenarios. Solid conductors maintain tighter impedance tolerance across the 1–500 MHz spectrum, reducing near-end crosstalk (NEXT) by 1.5–2 dB compared to equivalent stranded cables. This margin matters when deploying 48-port 10GBASE-T switches with all ports populated: the cumulative alien crosstalk from 47 adjacent pairs can erode the 12 dB margin required by TIA-568.2-D, especially in vertical cable managers where bundles run parallel for 1–2 meters. Panduit's foil-tape construction adds a physical barrier between pairs, reducing power-sum alien NEXT (PS-ANEXT) by 3–4 dB without the cost and stiffness of fully shielded F/UTP cable.
The 0.250-inch (6.4 mm) outside diameter keeps pathway fill ratios manageable: a 2-inch horizontal wire manager accommodates 96 of these patch cords at 40% fill (per TIA-568 guidelines), versus 72 cords for thicker 0.285-inch Cat 6A designs. The tangle-free latch uses a molded strain-relief boot that extends 0.4 inches beyond the plug body, creating a lever point for thumb-and-forefinger release without applying force to the latch tab itself. In practice, this reduces latch breakage by 60–70% during daily MAC work compared to standard boots, per Panduit field studies in hyperscale data centers. RapidID integration extends beyond initial deployment: scan both ends of the cable during installation, and RapidID software auto-populates a port map linking physical switch port, VLAN assignment, and destination device. When troubleshooting a failed link six months later, technicians scan the suspect cable to instantly pull up insertion-loss test results, installation date, and the installer's name—eliminating the "which cable goes where" guesswork that costs 15–20 minutes per ticket in large server farms.
The 13-meter length hits the sweet spot for inter-rack runs in data centers with 1.2-meter aisle spacing: two racks apart (2.4m rack width + 1.2m aisle + 2.4m rack width = 6m horizontal) plus 3–4 meters of vertical rise and 3–4 meters of horizontal wire-manager slack. Shorter 7-meter cords leave no slack for future re-patching; 20-meter cords create excess coil bulk that blocks airflow in hot aisles. The CM (Communications) flammability rating meets IEC 60332-1 vertical flame-test requirements for general-purpose horizontal cabling in commercial buildings; use Panduit's CMP-rated (plenum) variant for above-ceiling or air-handling spaces subject to NFPA 90A. PoE++ Type 4 support at 100W requires careful thermal management: bundled Cat 6A cables carrying sustained 100W loads can reach 60–65°C in sealed conduit, exceeding the 60°C rating for CM jackets. Limit bundle sizes to 24 cables or provide forced-air cooling in closed wire managers. The UTP6AX13MGY meets ANSI/TIA-1096-A safety requirements (formerly FCC Part 68) for connection to telecom networks, ensuring compatibility with legacy analog phone systems during hybrid voice/data migrations. Its 2500-cycle rating exceeds the 750-cycle minimum in IEC 60603-7 by 233%, matching the durability of Panduit's modular jacks and consolidation points—critical when deploying test benches or staging environments where cables see daily reconnection. For network architects validating 10Gig readiness in existing Cat 6A infrastructure, the TX6A patch cord serves as the reference standard: if your installed channels pass certification with this cord, they'll pass with any TIA-compliant cord.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →