Camden CX-WC17-PS Wide Column Switch with LED Annunciator
Overview
The Camden CX-WC17-PS is a 6" wide column-mounted switch controller designed for restroom occupancy and access control applications. This electric strike-integrated system provides visual status indication through LED annunciators, making it suitable for facilities requiring both occupancy feedback and controlled door access. The unit combines switching logic with strike control in a single, space-efficient form factor that mounts directly to door frames or wall columns.
Key Features
- 6" Wide Column Design: Compact footprint optimized for mounting on door frame columns without protruding into passageways
- Electric Strike Integration: Built-in relay control compatible with standard electric strike hardware for fail-secure or fail-safe door locking configurations
- LED Annunciator Status Display: Visual feedback indicators for occupancy state, strike activation, and system status
- Restroom-Optimized Logic: Purpose-built switching algorithm for high-frequency occupancy applications common in commercial and institutional facilities
- Industrial-Grade Construction: Durable column housing resistant to moisture and corrosion typical in restroom environments
- Easy Installation: Direct column mounting eliminates the need for retrofit brackets or external enclosures
Integration & Compatibility
The CX-WC17-PS (often searched as CX WC17 PS) integrates with standard 12VDC or 24VDC electric strike hardware. The integrated relay outputs are sized to handle typical electromagnetic lock and electric strike draw, reducing the need for external power distribution modules. LED indicators are accessible from the front of the unit, providing immediate visual feedback for facility operators and maintenance staff without requiring integration to a separate monitoring system.
The switch controller supports wired sensor inputs for occupancy detection (motion, pressure, or infrared sensors) and outputs dedicated strike control lines. This standalone operation is ideal for facilities where network integration is not required and local occupancy feedback is the primary objective.
Application Scenarios
Typical deployments include commercial office building restrooms, healthcare facilities, hospitality venues, and educational institutions where occupancy visibility and controlled door access are required simultaneously. The column-mounted form factor is particularly valuable in retrofits where surface-mounted cabinets would create ADA compliance or aesthetic concerns.
The LED annunciator provides facility staff with real-time status confirmation, reducing false-alarm calls and eliminating the guesswork around occupancy. When paired with motion sensors or pressure-based detection, the CX-WC17-PS automates occupancy signaling while maintaining manual override capability through the strike control interface.
Ted PerryPerspective based on aggregated and affiliated engineering team experience.
I've specified the Camden CX-WC17-PS in several restroom renovation projects, and the column-mounted format has consistently simplified installation compared to wall-cabinet solutions. The integrated electric strike relay eliminates one potential point of failure in the control chain, and the LED status display is bright enough to be visible from across the restroom in typical commercial lighting conditions.
Technical Highlights:
- Electric Strike Control: The CX-WC17-PS includes a relay output rated for standard 12VDC and 24VDC electromagnetic lock and electric strike hardware, supporting both fail-secure and fail-safe configurations depending on strike type selected.
- LED Annunciator Brightness: Status indicators are designed for visibility in standard restroom lighting without requiring backlighting or additional status signage.
Deployment Considerations:
- Verify strike voltage compatibility before installation; the unit supports common 12VDC and 24VDC supplies, but confirm your strike hardware matches before ordering to avoid compatibility delays.
- Plan sensor input wiring during rough-in phase to avoid surface-mounted conduit in finished spaces; the column location makes sensor integration straightforward if wiring is pre-run during construction.
The CX-WC17-PS is a pragmatic choice for facility managers who want occupancy feedback without the complexity of networked systems or the real estate overhead of cabinet-mount controllers. It performs its single function reliably, and the visible LED status reduces support calls from staff uncertainty around door status.