Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: IQBP-2
UPC: 656747182242
Condition: New
Write a Review 47% OFF

Middle Atlantic Blower Panel (Qty 2) 1 Space 100 CFM 32DB 220V Black Powder Coat Finish - IQBP-2

Middle Atlantic IQBP-2 1U Quiet Blower Panel — 100 CFM, 220-240V, 2-PackOverviewThe Middle Atlantic IQBP-2 is a 1U active rack blower panel engineered…

$689.00 $363.99 SAVE $325
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic Blower Panel (Qty 2) 1 Space 100 CFM 32DB 220V Black Powder Coat Finish - IQBP-2

$689.00
$363.99

Overview

SKU: IQBP-2
UPC: 656747182242
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic IQBP-2 1U Quiet Blower Panel — 100 CFM, 220-240V, 2-Pack

Overview

The Middle Atlantic IQBP-2 is a 1U active rack blower panel engineered for international deployments running 220–240V mains — a detail that matters when you're specifying AV or security rack builds outside North America. Sold as a quantity-two pack, the IQBP-2 delivers 100 CFM of forced-air cooling per unit in a single rack space, making it practical to stage cooling at multiple points in a tall rack without consuming the additional U-height that dual-fan 2RU assemblies demand. The black brushed and anodized aluminum finish integrates cleanly into standard 19-inch EIA racks, and with two mounting points, installation is a straightforward two-screw affair. For security integrators specifying camera head-end enclosures, NVR racks, or AV equipment bays that generate sustained heat loads, this panel provides active thermal management where passive venting falls short.

Key Features

  • 100 CFM Airflow per Unit: Moving 100 cubic feet per minute through a 1U opening is enough to meaningfully lower ambient temperature inside a mid-depth rack — relevant when NVRs, PoE switches, and edge appliances are all sharing the same enclosure. Two units in this pack means you can stage one at the base intake and one at the top exhaust without ordering separately.
  • 220–240V AC Input: The IQBP-2 is designed for international mains voltage, not the 100–120V North American standard. This is the correct panel for EU, UK, Middle East, Asia-Pacific, and Latin American deployments where local mains runs at 220–240V. Specifying the wrong voltage panel is a common field mistake — verify your mains before ordering.
  • 12 VDC Internal Conversion: The panel converts mains AC to 12 VDC internally to drive the blower motor, so there's no external power brick or secondary wiring run. The integrated power supply simplifies rack wiring and reduces points of failure.
  • 1 Rack Unit Height (1.75 in): At exactly 1U, this panel slots into standard EIA 19-inch racks without requiring adjacent space clearance. The 19-inch width and dual mounting points confirm compatibility with full-width rack rails — no adapter brackets needed for standard four-post or two-post open frames.
  • 10.1-Inch Depth: At 10.1 inches deep, the IQBP-2 fits comfortably in mid-depth wall-mount enclosures (typically 14–18 inches internal depth) and shallow server racks. Confirm your rack's internal depth before installing — very shallow enclosures under 12 inches may require checking clearance at the rear rail.
  • Active Component, DC Power Type: Active classification means this is a powered blower, not a passive vent panel. It requires a live circuit at the rear of the rack. The DC power type (12 VDC internal) means the blower motor runs quietly and efficiently — the 32 dB noise rating keeps it appropriate for environments where fan noise is a concern, such as control rooms or conference-adjacent equipment closets.
  • Black Brushed and Anodized Finish: The anodized aluminum front panel resists corrosion and abrasion in environments where racks are accessed frequently. It integrates with standard black rack furniture from most manufacturers without finish mismatch.
  • Available Internationally / TAA Non-Compliant: The IQBP-2 is cleared for international sale and ships globally. However, it is explicitly TAA non-compliant — if your project is a U.S. federal government installation with a Trade Agreements Act requirement, this panel cannot be used. Specify a TAA-compliant alternative in that case.

Integration & Compatibility

The IQBP-2 installs into any standard 19-inch EIA rack with two mounting points. The 1U form factor makes it straightforward to position at the base of a rack as an intake blower or near the top as an exhaust assist, depending on your rack's airflow strategy. Because the panel handles its own AC-to-DC conversion internally, it wires directly to a 220–240V rack PDU outlet — no intermediate power conditioning required. For rack infrastructure builds combining UPS units, patch panels, and active security appliances, positioning the blower adjacent to the highest heat-generating devices (NVRs, PoE switch modules) yields the most effective thermal relief. Integrators working on Middle Atlantic rack systems will find the IQBP-2 mechanically consistent with the broader QBP blower panel family. For North American 100–120V installations, Middle Atlantic offers equivalent panels in the same product line — the IQBP-2 is specifically the international-voltage variant.

Frequently Asked Questions

Q: Does the IQBP-2 work on North American 110/120V power?

A: No. The IQBP-2 is rated for 220–240V AC input only. For North American 100–120V rack installations, you need the domestic-voltage variant in the Middle Atlantic QBP blower panel family. Plugging a 220V-only device into a 110V circuit will result in the blower running below spec or not running at all.

Q: Is the IQBP-2 TAA compliant for U.S. government projects?

A: No. The IQBP-2 is explicitly listed as TAA non-compliant. It cannot be used on U.S. federal projects with Trade Agreements Act requirements. Verify compliance requirements with your contracting officer before specifying.

Q: What rack depth is required for the IQBP-2?

A: The IQBP-2 is 10.1 inches (25.7 cm) deep. It will fit in any rack with at least 11 inches of internal usable depth. Most standard 2-post and 4-post racks with 14 inches or more of internal depth will accommodate it without issue.

Q: How loud is the IQBP-2 in operation?

A: The IQBP-2 is rated at 32 dB. That is relatively quiet for an active 100 CFM blower — comparable to a quiet desktop fan. It's suitable for control rooms and equipment closets adjacent to occupied spaces, though it will be audible in a very quiet room.

Q: Can I use both units in this pack in the same rack?

A: Yes. Deploying both units in the same rack is a standard approach — one near the bottom as an intake and one near the top as an exhaust to create a defined airflow path through the rack. Each unit requires its own 220–240V outlet on your rack PDU.

Q: What is the IQBP-2's UPC code?

A: The UPC for the IQBP-2 is 656747182242.

Eden Phillips
Eden Phillips

The IQBP-2 comes up frequently in international rack builds where integrators forget to spec the right mains voltage — then wonder why the blower isn't moving air. This panel is purpose-built for 220–240V environments, and its internal AC-to-12VDC conversion means you wire it directly to a standard international PDU outlet with no secondary power supply needed. The 100 CFM rating and 32 dB acoustic spec make it a practical pick for equipment closets where noise is a constraint.

Technical Highlights:

  • 100 CFM at 32 dB: Delivering 100 CFM while staying at 32 dB is a meaningful balance — you're moving real air volume without creating the kind of fan noise that becomes a problem in AV or conference-adjacent closets. Many comparable active panels hit 38–42 dB at similar airflow.
  • 220–240V AC Input with 12 VDC Internal Conversion: The integrated power supply eliminates a separate wall-wart or DIN-rail PSU in the rack. One outlet on your PDU handles the whole unit — cleaner wiring, fewer failure points.
  • 1U at 10.1-Inch Depth: The 10.1-inch depth fits mid-depth wall-mount enclosures commonly used in distributed security head-end builds. It is tight but workable in 12-inch-depth enclosures — measure your rear rail setback before committing.

Deployment Considerations:

  • Each unit in the two-pack needs its own 220–240V circuit on your PDU. Budget two outlet positions per rack where you deploy both panels — overlook this and you'll be pulling power from an adjacent non-standard outlet.
  • The IQBP-2 is TAA non-compliant — a hard stop for any U.S. government-funded installation. This is not a gap that can be waived; you need a different panel for those projects.

This panel is the right call for international surveillance and AV rack builds — particularly in EU and APAC regional offices where 220–240V mains is standard and thermal management of dense NVR or encoder racks is a recurring challenge. The two-pack quantity makes intake-plus-exhaust staging simple without a second purchase order.

Specifications
Mount Type: Rack
Input Voltage: 220 - 240V
Airflow Cfm: 100
Depth: 10.1 in (25.7 cm)
Height: 1.75 in (4.4 cm)
Rack Units: 1 RU
Shipping Weight: 5.2 lbs (2.4 kg)
Output Voltage: 12 VDC
Width: 19 in (48.3 cm)
Available Internationally: Yes
Component Type: Active
Finish: Black Brushed and Anodized
Mounting Points: 2
Power Type: DC
Taa Compliant: No
Upc: 656747182242
Ac Voltage Input: 220 - 240V
Cfm: 100
Volts Dc: 12 VDC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources