CyberPower Battery - Lead-acid - 12V - 5.5 AH - 2 Year Limited Warranty - Sealed - APCRBC141-CP

CyberPower APCRBC141-CP Sealed Lead-Acid Battery Pack Overview The CyberPower APCRBC141-CP is a 12V 5.5Ah sealed lead-acid battery module designed as …

$369.00 $342.99 SAVE $26
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

CyberPower Battery - Lead-acid - 12V - 5.5 AH - 2 Year Limited Warranty - Sealed - APCRBC141-CP

$369.00
$342.99

Overview

SKU: APCRBC141-CP
UPC: 649532939435
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

CyberPower APCRBC141-CP Sealed Lead-Acid Battery Pack

Overview

The CyberPower APCRBC141-CP is a 12V 5.5Ah sealed lead-acid battery module designed as a replacement or expansion pack for UPS systems protecting surveillance infrastructure, network equipment, and access control systems. This is a genuine CyberPower battery—no compatibility guessing, no grey-market risk. The APCRBC141-CP ships as a set of six individual 12V 5.5Ah cells, delivering 33Ah aggregate capacity when configured in parallel, a practical choice for extending runtime on mid-range and enterprise UPS units in data closets and network hubs.

Key Features

  • Sealed Lead-Acid (SLA) Design: Maintenance-free operation with no liquid top-ups required—critical for unattended equipment closets where acid spills risk network infrastructure damage. The sealed construction also eliminates hydrogen gas venting concerns in compact spaces.
  • 12V 5.5Ah per Module: Each cell in the six-pack delivers 5.5 amp-hours at 12V nominal. In parallel configuration, you gain 33Ah total capacity, translating to proportionally longer UPS runtime per watt-hour of load. For example, a 500W surveillance system can run 3–4 hours instead of 30–45 minutes with the original single battery.
  • Compact Footprint: Dimensions 8.25 × 3.0 × 15.75 inches per battery (210 × 77 × 400 mm), allowing stacking or side-by-side mounting in standard UPS enclosures or cabinet rails without requiring dedicated expansion racks.
  • Operating Range 32–104°F (0–40°C): Rated performance across typical data center and equipment closet temperatures. Below freezing or above 104°F, capacity drops—relevant if your UPS sits in unheated outdoor cabinets or near HVAC exhaust vents. Humidity tolerance 0–90% RH (non-condensing) protects against moisture in mixed-use facilities.
  • 2-Year Manufacturer Warranty: Factory-backed coverage against defective cells. Real-world SLA lifespan depends on cycle count and float charge voltage regulation; expect 3–5 years in typical stationary UPS duty with proper charger settings.
  • Weight and Handling: Each battery weighs 24.5 lbs (11.11 kg). Six-pack totals 147 lbs—manageable for two-person delivery but heavy enough to warrant proper lifting equipment in racks. Account for this when planning cabinet weight limits and securing cables to frame.

Integration & Compatibility

The APCRBC141-CP is a direct replacement or parallel-expansion module for CyberPower UPS systems. Verify your UPS model accepts external battery cartridges or supports parallel battery configurations before ordering. Connect batteries in parallel (positive to positive, negative to negative) using appropriately rated terminals and cable lugs—undersized connectors will cause voltage drop and reduce available runtime. Ensure your UPS charger delivers the correct float voltage (typically 13.5–13.8V for SLA at 25°C); over-voltage charging accelerates water loss and plate corrosion, while under-voltage leaves cells under-charged and reduces capacity recovery. If your UPS lacks an integrated charger or supports only single batteries, you will need an external SLA charger rated for parallel strings.

What's in the Box

Six sealed lead-acid battery modules (APCRBC141-CP), each 12V 5.5Ah. No mounting brackets, cables, or connectors are included—you source those separately based on your cabinet layout and connector type (Anderson PowerPole, ring terminals, or breaker-rated lugs are common).

Frequently Asked Questions

Q: Can I mix the APCRBC141-CP with other battery brands or capacities in a parallel string?

A: Not recommended. Mixing brands or capacity ratings (e.g., 5.5Ah with 7Ah) causes uneven charge/discharge cycles and cell damage. Use matched sets—all APCRBC141-CP units, all same age if possible. If you need higher capacity, add more APCRBC141-CP modules in parallel, not third-party batteries.

Q: What is the warranty on the APCRBC141-CP?

A: 2-year limited manufacturer warranty from the date of purchase. Coverage includes defective cells that fail to hold charge under normal float-charge conditions in a stationary UPS. Warranty does not cover damage from over-charging, physical damage, or use outside the 0–40°C operating range.

Q: How long will the APCRBC141-CP runtime last in a typical surveillance UPS?

A: Runtime depends on the UPS load (watts) and your inverter efficiency (typically 85–92%). A 500W load drawing 33Ah @ 12V delivers roughly 400Wh usable energy, supporting approximately 45–50 minutes of runtime. A lighter 200W load extends this to 2+ hours. Check your UPS manual for the runtime graph specific to your load and battery configuration.

Q: Do I need special installation equipment for six batteries?

A: Yes. Each battery is 24.5 lbs; six total 147 lbs. Use a two-person team or a hand truck. Ensure your UPS enclosure or battery cabinet is secured to floor or wall (UPS units can tip if stacked batteries shift). Wire connectors must be rated for the combined current—calculate based on your inverter's maximum discharge current in amps, then select cable and terminals rated 20–25% above that amperage.

Q: Will the APCRBC141-CP work at outdoor temperatures below 32°F?

A: Below freezing, SLA capacity drops dramatically—expect 30–50% of rated capacity at 0°C and essentially zero usable energy at −10°C or colder. If your UPS cabinet is outdoors or unheated, insulate it or move the battery pack indoors. For harsh environments, specify industrial lithium or nickel-cadmium batteries rated for extended temperature ranges.

Marty Allison
Marty Allison

The APCRBC141-CP is the right play when you're extending runtime on a CyberPower UPS protecting surveillance recorders, network switches, or access-control panels in a data closet. I spec this battery pack for sites where five-minute battery backup isn't enough—you need 45 minutes to an hour to let cameras finish event writes, let the recorder gracefully shut down, or ride out a brownout without losing data. The six-pack configuration (33Ah aggregate) gives you real runway at typical load levels.

Technical Highlights:

  • 12V 5.5Ah per Module, 33Ah Parallel Total: Six sealed cells in parallel deliver enough amp-hours to extend typical 500W surveillance loads from 30–45 minutes (OEM single battery) to 45–60 minutes. Calculate your actual load in watts, divide by inverter efficiency (assume 90%), and multiply by total Ah to estimate runtime in minutes.
  • Sealed Lead-Acid, Zero Maintenance: No refilling, no hydrogen venting—equipment closets stay safe from acid spills and gases. In a tight server room with no active ventilation, this matters. Traditional flooded batteries would require a fume hood or external venting.
  • Operating Range 0–40°C (32–104°F): Suitable for climate-controlled data closets and indoor network hubs. Below freezing, capacity collapses; above 104°F, charging becomes inefficient and plates degrade faster. If your cabinet hits 50°C under peak load, you're down 10–15% usable capacity and cutting lifespan.

Deployment Considerations:

  • Weight is a real factor here—147 lbs for six modules. If you're retrofitting into an existing cabinet, check load ratings on your DIN rail or mounting shelf. A single-point anchor to the frame is not adequate; cable-strap or bolt all six units to prevent sliding or tipping during earthquakes or vibration.
  • Charger voltage regulation is critical. Over-charge at 14.5V+ and you'll boil off water, reducing cell life from 3–5 years to 12–18 months. Confirm your UPS charger is set to 13.5–13.8V float for stationary SLA duty. If your UPS charger is dumb (no voltage adjustment), you're on borrowed time with any SLA battery.

Spec the APCRBC141-CP for surveillance infrastructure that cannot afford unplanned downtime—retail camera systems, warehouse access-control backup, or remote facility NVR clusters where a utility fault means lost recording and delayed incident response. Pair it with a UPS that has intelligent float charging and you'll get five solid years of reliable backup power.

Specifications
Battery Quantity: 6
Battery Size: 12 V / 5.5 Ah
Battery Type: Sealed Lead-Acid
Dimensions Width Height Depth Inches: 8.25 x 3.0 x 15.75
Dimensions Width Height Depth Millimeters: 210 x 77 x 400 mm
Weight Pounds: 24.5 lbs.
Weight Kilograms: 11.11 kg
Warranty: 2-Year Limited
Operating Relative Humidity: 0% - 90%
Operating Temperature: 32 °F - 104 °F (0 °C - 40 °C)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support