Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SY150K250DL-PD
Condition: New
Write a Review 33% OFF

APC Symmetra PX 150KW Scalable to 250KW with Maintenance Bypass Left & Distribut - SY150K250DL-PD

APC by Schneider Electric SY150K250DL-PD Symmetra PX 150KW Scalable to 250KW UPS with Maintenance Bypass and DistributionOverviewThe APC by Schneider …

$245,535.00 $165,523.99 SAVE $80011
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Symmetra PX 150KW Scalable to 250KW with Maintenance Bypass Left & Distribut - SY150K250DL-PD

$245,535.00
$165,523.99

Overview

SKU: SY150K250DL-PD
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SY150K250DL-PD Symmetra PX 150KW Scalable to 250KW UPS with Maintenance Bypass and Distribution

Overview

The APC by Schneider Electric SY150K250DL-PD is an enterprise-class, modular uninterruptible power supply built for large-scale data centers, critical infrastructure facilities, and industrial environments that cannot tolerate power interruptions. Starting at 150KW of protected output and field-scalable up to 250KW within the same frame, this system is engineered for organizations that need room to grow without replacing core infrastructure. The integrated left-side maintenance bypass and built-in distribution panel are factory-included — not optional add-ons — which simplifies procurement and reduces installation complexity compared to systems that require separate bypass cabinets.

Key Features

  • 150KW Base, 250KW Scalable: Deploy at 150KW today and scale to 250KW by adding power modules — no new cabinet, no infrastructure replacement. This matters in data centers where load grows with compute density and retrofitting a UPS mid-operation carries significant risk.
  • Integrated Maintenance Bypass (Left Configuration): The factory-built left-side bypass lets technicians safely take the UPS offline for service or module swaps without dropping protected loads. For 24/7 facilities, this is a non-negotiable operational requirement, not a luxury — separate bypass enclosures add both cost and floor space.
  • Integrated Distribution Panel: Output distribution is built into the same enclosure, eliminating a separate PDU cabinet. This reduces the number of single points of failure in the power chain and keeps the footprint compact — a real advantage in high-density raised-floor environments where every rack unit and floor tile counts.
  • Modular Architecture: The Symmetra PX platform's modular design means power and battery modules are hot-swappable, enabling N+1 or N+2 redundancy configurations and minimizing mean time to repair. A failed module swap does not require a scheduled maintenance window.

Frequently Asked Questions

Q: What is the maximum power capacity of the SY150K250DL-PD?

A: The SY150K250DL-PD starts at 150KW and is field-scalable up to 250KW by adding power modules within the existing frame — no cabinet replacement required.

Q: Does the SY150K250DL-PD include a maintenance bypass?

A: Yes. A maintenance bypass is factory-integrated on the left side of the unit, allowing the UPS to be safely serviced without interrupting connected loads.

Q: Is the distribution panel included, or is it a separate purchase?

A: The distribution panel is included as part of the SY150K250DL-PD configuration — it is not a separate accessory or optional upgrade.

Q: What type of facilities is the SY150K250DL-PD designed for?

A: This system targets large-scale data centers, enterprise IT facilities, and critical infrastructure environments requiring high-capacity, scalable UPS protection with built-in redundancy and serviceability features.

Eden Phillips
Eden Phillips

When a customer is evaluating the SY150K250DL-PD, the first question I ask is whether they have a realistic load growth projection for the next five years. Starting at 150KW with a 250KW ceiling in the same frame is a real operational advantage — it defers a full infrastructure replacement and lets the power system grow with the compute environment rather than ahead of it.

Technical Highlights:

  • 150KW to 250KW Scalability: Field-upgradeable within the existing enclosure — module additions, not cabinet replacements. This keeps the capital expense tied to actual load growth, not projected maximums.
  • Factory-Integrated Maintenance Bypass (Left Side): The bypass is not an afterthought. A left-side bypass in a shared aisle configuration is a layout decision — confirm your cabinet row orientation before ordering, because bypass placement affects maintenance access and aisle clearance.
  • Integrated Distribution Panel: Having distribution built in reduces inter-cabinet cabling and eliminates a separate PDU as a failure domain. For environments with strict availability SLAs, fewer enclosures in the power chain means fewer potential failure points to monitor and maintain.

Deployment Considerations:

  • Confirm floor loading capacity before installation — a 150–250KW UPS with integrated bypass and distribution will have substantial weight; engage a structural engineer if the raised floor rating is marginal.
  • The left-side bypass orientation is fixed at the factory. If your rack layout requires right-side bypass access, this specific model is not the correct choice — request the appropriate variant with right-side bypass configuration.

The SY150K250DL-PD is best positioned in a purpose-built data center or critical infrastructure facility where the operations team has a defined load growth roadmap, a structured PM schedule that will actually leverage the bypass, and floor space planned around the integrated distribution footprint rather than bolted-on PDUs.

Specifications
Mfr: SY150K250DL-PD
Unspsc: 39121011
Item: 001187300
Cnet Cat Code: 10061402
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources